• Title/Summary/Keyword: Proximal surface

Search Result 182, Processing Time 0.023 seconds

HISTOLOGIC FEATURE AND INFILTRATION OF ADHESIVE RESIN ACCORDING TO PRETREATMENT ON PROXIMAL EARLY CARIES LESION (평활면 초기 우식병소의 표면처리에 따른 조직상 및 접착제의 침투 양상 비교)

  • Kim, In-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Early enamel caries is commonly remineralized by the patient‘s improved oral hygiene or fluoridation, however the result is clinically unreliable. As an alternative, we tried to seal the lesions with low-viscosity light-curing resin. The aim of the present study was to search the proper methods of the adequate pretreatment prior to applying adhesive resin on natural proximal caries lesions. Thirty nine extracted deciduous molar teeth showing proximal early caries lesion were used for this study. They were divided into 5 groups : Group 1; only carefully cleaned with water, group 2; etched with 15% HCl for 15s, group 3; etched with 35% phosphoric acid for 15s, group 4; etched with 35% phosphoric acid for 30s, and group 5; cleaned with 0.5% NaOCl. Following results were obtained by evaluating with SEM and CLSM after applied with adhesive resin. 1. As a result of SEM evaluation, group 2 showed clearly removed surface layer, group 3,4 showed partially removed surface layer irregularly, group 5 showed slightly removed surface layer. 2. Group 2 showed the deepest infiltration depth, followed by group 4, group 3, group 5, group 1 and besides group 5, other groups showed significantly deep infiltration depth. (p < 0.01) In conclusion, the best methods of the adequate pretreatment on natural proximal caries lesion for deep infiltration of adhesive resin was to etch with 15% HCl for 15s.

  • PDF

Effect of Electrode Placement on Procaine Iontophoresis (전극배치가 Procaine 이온도입에 미치는 영향)

  • Lee, Jae-Hyoung;Song, In-Young;Kook, Jee-Youn
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.2
    • /
    • pp.399-403
    • /
    • 1997
  • The purpose of this study was to determine the efficacy of electrode placement on procaine iontophoresis. Thirty-three healthy students with an age range of 19 to 34 years, were participated in this study. The subjects were randomly assigned into 3 groups. Each subjects received iontophoresis on the proximal 1/3 of volar surface of dominant forearm with soft cotton pad($3.5{\times}3.5cm$) soaked in 2 ml of 4% procaine hydrochloride (pH 5.1) at 4 mA for 10 minutes(total current 40 mA min) of anodal DC. In transversal electrode placement(TEP) group, dispersive electrode was placed on the proximal 1/3 of dorsal surface of the forearm. In longitudinal electrode placement (LEP) group and control group, dispersive electrode were placed on the distal 1/3 of volar surface of the forearm. After procaine iontophoresis, duration of anesthesia were evaluated at five minutes intervals on five random locations in the iontophoretically area using a 21-gauge sterile hypodermic needle pressed with 1 mm invagination until return the sharp pin-pricking pain sensation. The data were ana lysed with one-way ANOVA to determine signific~nt differences between groups. The results showed significantly differences in the local anesthetic duration between the 3 groups(p<0.001). The anesthetic durations of TEP group and LEP group were significantly longer when compared with control group(p<0.05). Anesthetic durations of TEP group and LEP group were not significantly difference, but anesthetic duration of LEP group tends to longer than TEP group. In view of these results, clinicians should consider the electrode placement method when performing the iontophoresis.

  • PDF

SCANNING PROBE NANOPROCESSING

  • Sugimura, Hiroyuki;Nakagiri, Nobuyuki
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.314-324
    • /
    • 1996
  • Scanning probe microscopes (SPMs) such as the scanning tunneling microscope (STM) and the atomic force microscope (AFM) were used for surface modification tools at the nanometer scale. Material surfaces, i. e., titanium, hydrogen-terminated silicon and trimethylsilyl organosilane monolayer on silicon, were locally oxidized with the best lateral spatial resolution of 20nm. The principle behind this proximal probe oxidation method is scanning probe anodization, that is, the SPM tip-sample junction connected through a water column acting as a minute electrochemical cell. An SPM-nanolithogrphy process was demonstrated using the organosilane monolayer as a resist. Area-selective chemical modifications, i. e., etching, electroless plating with gold, monolayer deposition and immobilization of latex nanoparticles; were achieved in nano-scale resolution. The area-selectivity was based on the differences in chemical properties between the SPM-modified and unmodified regions.

  • PDF

Arrayed Tip based Pattern Lithography with Built-in Capacitive Proximal Leveling Sensor (내장형 정전용량 근접 센서를 이용한 다중 팁 기반 패턴 인쇄)

  • Han, Yoonsoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.5
    • /
    • pp.239-245
    • /
    • 2019
  • To increase the throughput of tip-based nanolithography (TBN), one approach is to use a large array of such tips working in parallel. It is important to maintain co-planarity between the tip array and the writing surface. A slight misalignment can cause large discrepancies of contact force and feature sizes. We report a capacitive proximity sensor built-in with the TBN array for leveling an arrayed polymer pen array. The device allows alignment between an array of writing tips and the writing substrate without contact and contamination. The angular sensitivity of the sensor is $0.05^{\circ}$ for an array with maximum tip-to-tip separation of 100 mm.

THREE DIMENSIONAL LINEAR MEASUREMENT OF PROXIMAL TIBIA IN MEDIAL AND LATERAL APPROACH FOR BONE HARVESTING (경골 근위부 골채취를 위한 내측 및 외측 접근법시의 삼차원적 길이계측)

  • Nam, Woong;Park, Won-Se;Jeong, Ho-Gul;Hu, Kyung-Seok;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.307-311
    • /
    • 2007
  • Purpose: The aim of this study was simply assessing linear measurements in the lateral and medial approach, respectively, for bone harvesting using anatomic and three-dimensional(3D) computed tomographic(CT) analyses on a dried cadaveric proximal tibia. In addition, the availability of the three-dimensional computed tomographic(3D-CT) analysis was also estimated. Materials and methods: Ten dried proximal tibia were obtained from five Korean cadavers. Four the reference points, the SM(superior-medial), IM(inferior-medial), SL(superior-lateral), and IL(inferior-lateral) were marked around the tibial tuberosity. The PM(posterior-medial) and PL(posterior-lateral) points were randomly marked at points farthest from the lateral and medial reference points, respectively, in the posterior border of the superior articular surface of both condyles. All measurements were obtained on the dried proximal tibia. After computed tomography had been performed, the three dimensional images were reconstructed using V works $4.0^{TM}$(Cybermed Inc., Seoul, Korea), and the length between the reference points were measured three dimensionally using the method described above. The error between the mean actual and mean 3D-CT measurements was calculated in order to determine the availability of the three dimensional computed tomographic analysis. Results: The length between the reference points was greatest at the IL-PM, which averaged $65.39mm{\pm}10.35$. This was followed by the SL-PM with $63.24mm{\pm}8.10$, the IM-PL with $58.09mm{\pm}10.02$, and the SM-PL with $51.99mm{\pm}9.06$. The differences between the IL-PM and SM-PL were 13.4 mm. The mean values were 55.04 mm in the medial approach and 64.32 mm in the lateral approach, and the differences between medial and lateral were 9.28 mm. The error between the mean actual and mean 3D-CT measurements was 0.31% and the standard deviation was 0.28%. Conclusion: The anatomical and three dimensional computed tomographic analysis indicates that there was only a 9.28 mm linear difference between the lateral and medial approach. This is consistent with previous studies, which showed that there was little difference between the two approaches in terms of the bone volume. In addition, the error(0.31%) and the standard deviation(0.28%) were considered low, demonstrating high accuracy of 3D-CT. Therefore it can be used in preoperative treatment planning.

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

Comparison of digital and conventional radiography for the detection of proximal surface caries

  • Park, Si-Seung;Cho, Young-Gon
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.592.1-592
    • /
    • 2001
  • Conventional intraoral radiography continues to be the most widely used for the diagnosis of dental caries. But conventional intraoral film has several shortcomings, including processing error, increased radiation dose, etc. Recently, various digital radiographs substitude for conventional radiography to overcome these disadvantages. The digital radiographies are numerous advantages, including elimination of processing errors, lower radiation dose, image quality enhancements such as contrast and density modulation.(omitted)

  • PDF

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

Evaluation of Biomechanical Stability of Newly Developed Revision Total Knee Arthroplasty through Strain and Stress Distribution Analysis within the Tibia: Finite Element Analysis (경골 내 변형률 및 응력 분포 특성 분석을 통한 새로이 개발된 재치환용 인공슬관절의 생체역학적 안정성 평가: 유한요소해석)

  • Han, Paul;Jang, Young-Woong;Yoo, Oui Sik;Kim, Jung Sung;Kim, Han Sung;Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.14-23
    • /
    • 2013
  • In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp., Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling, leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.

Short Humeral Stems in Shoulder Arthroplasty

  • Oh, Hwang Kyun;Lim, Tae Kang
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.2
    • /
    • pp.105-110
    • /
    • 2018
  • Since the introduction of shoulder arthroplasty by Neer in 1974, the design of not only the glenoid component but also the humeral component used in shoulder arthroplasty has continually evolved. Changes to the design of the humeral component include a gradually disappearing proximal fin; diversified surface finishes (such as smooth, grit-blasted, and porous coating); a more contoured stem from the originally straight and cylindrical shape; and the use of press-fit uncemented fixation as opposed to cemented fixation. Despite the evolution of the humeral component for shoulder arthroplasty, however, stem-related complications are not uncommon. Examples of stem-related complications include intraoperative humeral fractures, stem loosening, periprosthetic fractures, and stress shielding. These become much more common in revision arthroplasty, where patients are associated with further complications such as surgical difficulty in extracting the humeral component, proximal metaphyseal bone loss due to stress shielding, intraoperative humeral shaft fractures, and incomplete cement removal. Physicians have made many attempts to reduce these complications by shortening the stem of the humeral component. In this review, we will discuss some of the limitations of long-stem humeral components, the feasibility of replacing them with short-stem humeral components, and the clinical outcomes associated with short-stemmed humeral components in shoulder arthroplasty.