• 제목/요약/키워드: Proximal fracture

검색결과 249건 처리시간 0.021초

Antiglide 금속판을 이용한 족관절의 외과 골절의 치료 (The Anti-glide Plate in the Treatment of Lateral malleloar fracture)

  • 김도영;신주호;조원호;황현철
    • 대한족부족관절학회지
    • /
    • 제5권1호
    • /
    • pp.18-22
    • /
    • 2001
  • Most of Danis-Weber type B fracture has an oblique fracture plane proximal posteriorly to distal anteriorly. In these cases, the lateral plate has become widely accepted. However some limitation to the use of the lateral plate exist. The plate must be bent accurately and the screws in the distal fragment must be unicortical to avoid penetration into the joint, predisposing it to poor fixation in the osteoporotic bone. In 1982, Brunner and Weber introduced the antiglide plate for fixation of the shaft oblique fracture of the distal fibula, but it has not widely used. The author reviewed 21 cases treated by antiglide plate fixation from March, 1995 to March, 1999 which could be follow-up more than 1 year. We analysed the result radiographically and clinically using Ankle-Hindfoot scale(100 % total) of the American Orthopedic Foot and Ankle Society. The results obrained were as follows: 1. All fracture were united at average 8 weeks clinically and radiographically. 2. According to the Ankle- Hindfoot scale, 8 cases were above 90 points, 11 cases were beet ween 80 and 89 points and two cases were below 80 points. 3. One case had an injury to intermediate dorsal cutaneous nerve.

  • PDF

What is the interobserver agreement of displaced humeral surgical neck fracture patterns?

  • Reinier W. A. Spek;Laura J. Kim
    • Clinics in Shoulder and Elbow
    • /
    • 제25권4호
    • /
    • pp.304-310
    • /
    • 2022
  • Background: The Boileau classification distinguishes three surgical neck fracture patterns: types A, B, and C. However, the reproducibility of this classification on plain radiographs is unclear. Therefore, we questioned what the interobserver agreement and accuracy of displaced surgical neck fracture patterns is categorized according to the modified Boileau classification. Does the reliability to recognize these fracture patterns differ between orthopedic residents and attending surgeons? Methods: This interobserver study consisted of a randomly retrieved series of 30 plain radiographs representing clinical practice in a level 1 and a level 2 trauma center. Radiographs were included from patients (≥18 years) who sustained an isolated displaced surgical neck fracture if they were taken ≤1 week after initial injury. A ground truth was established by consensus among three senior orthopedic surgeons. All images were assessed by 17 orthopedic residents and 17 attending orthopedic trauma surgeons. Results: Agreement for the modified Boileau classification was fair (κ=0.37; 95% confidence interval [CI], 0.36-0.38) with an accuracy of 62% (95% CI, 57%-66%). Comparison of interobserver variability between residents and attending surgeons revealed a significant but clinically irrelevant difference in favor of attending surgeons (0.34 vs. 0.39, respectively, Δκ=0.05, 95% CI, 0.02-0.07). Conclusions: The modified Boileau classification yields a low interobserver agreement with an unsatisfactory accuracy in a panel of orthopedic residents and attending surgeons. This supports the hypothesis that surgical neck fractures are challenging to categorize and that this classification should not be used to determine prognosis if only plain radiographs are available.

대량의 골 및 연부조직 결손을 동반한 분쇄 경골 골절에서의 급성 단축술과 점진적 연장술 - 증례 보고 - (Acute Shortening and Gradual Lengthening for a Comminuted Tibia Fracture with Massive Bone and Soft Tissue Defect - Case Report -)

  • 한호성;허정규;송철호;백구현;이영호;공현식
    • Archives of Reconstructive Microsurgery
    • /
    • 제20권1호
    • /
    • pp.68-73
    • /
    • 2011
  • Traditional management of comminuted tibia fractures with massive bone and soft tissue defect includes soft tissue coverage and bone grafting. However, this method requires a large flap and a substantial amount of bone graft. Acute shortening can reduce the amount of required soft tissue and bone graft. We report a case of open tibia and fibula fracture with severe bone and soft tissue defect that was successfully treated by acute shortening of the tibia with immediate fibular strut bone graft and then by gradual lengthening of the tibia at its proximal metaphysis.

  • PDF

역공학과 쾌속조형공정을 이용한 정형외과수술기법 개발에 관한 연구 (Investigation into the Development of Technology for Orthopeadic Surgery Utilizing Reverse Engineering and Rapid Prototyping Technology)

  • 안동규;이준영;양동열;한길영
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.188-196
    • /
    • 2004
  • The objective of this paper is to propose a new technology of the orthopaedic surgery using the combination of reverse engineering (RE) based on CT data and rapid prototyping (RP). The proposed technology utilizes symmetrical characteristics of the human body and capability of the combination of RE and RP, which rapidly manufactures three-dimensional parts from CT data. The original .stl data of injured extents are generated from the mirror transformation of .stl file fur uninjured extents. The physical shape before injuring is manufactured from RP using the original .stl data. Subsequently, pre-operative planning, such as a selection of proper implants, preforming of the implant, a decision of fixation locations and an insert position for the implant, an estimation of the invasive size, and pre-education of operators are performed using the physical shape. In order to examine the applicability and the efficiency of the proposed surgical technology, various case studies, such as a distal tibia commented fracture, a proximal tibia plateau fracture and an iliac wing fracture of pelvis, are carried out. From the results of case studies, it has been shown that the proposed technology is an effective surgical tool of the orthopaedic surgery reducing the operational time, the operational cost, the radiation exposure of the patient and operators, and morbidity. In addition, the proposed technology could improve the accuracy of operation and the speed of rehabilitation.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

The Incidence of Venous Thromboembolism Following Shoulder Surgery: A Pilot Study

  • Cho, Chul-Hyun;Jang, Hyung-Gyu;Park, Ui-Jun;Kim, Hyoung Tae
    • Clinics in Shoulder and Elbow
    • /
    • 제20권1호
    • /
    • pp.18-23
    • /
    • 2017
  • Background: To assess the incidence of venous thromboembolism (VTE) following shoulder surgery and to evaluate the role of postoperative duplex ultrasonography. Methods: The study comprised a total of 224 patients who underwent shoulder surgery, including 180 shoulder arthroscopic surgeries, 28 shoulder arthroplasties, and 16 plate fixations for proximal humerus fracture between January 2014 and December 2014. The mean age of patients was 59.0 years, and there were 81 men and 143 women. Clinical data, including body mass index, blood tests, metabolic work-up for liver and renal function, previous, and present medical history, were evaluated. Duplex ultrasonography in the operative arm was performed on 2 to 4 days after surgery. Results: The overall incidence of VTE following shoulder surgery was 0.45% (1/224). One patient with open reduction and plate fixation for proximal humerus fracture had asymptomatic deep vein thrombosis that showed complete remission after anticoagulant medication during a 2-month period. Four patients had asymptomatic superficial cephalic vein thrombosis and complete remission without any treatment. There was no case of pulmonary embolism. Conclusions: The incidence of VTE following shoulder surgery was extremely low in Asians. Duplex ultrasonography may be not considered a routine follow-up of shoulder surgery and can be selectively performed in high-risk or symptomatic patients for VTE.

역행성 동맥 혈류를 이용한 원위 유리피판술의 실험적 연구 (Experimental Study on Distally Based Free Flap Using Retrograde Arterial Flow)

  • 이민구;민경원
    • Archives of Reconstructive Microsurgery
    • /
    • 제7권1호
    • /
    • pp.15-19
    • /
    • 1998
  • Microsurgical free-tissue transfer has allowed surgeons to salvage injured limbs but choosing appropriate healthy recipient vessels has proved to be a difficult problem. Retrograde flow flaps are established in island flaps. Retrograde flow anastomosis could prevent the possible kinking and twisting of the arterial anastomosis. By not interrupting the proximal blood flow to the fracture or soft tissue defect site, the compromise of fracture or wound healing might be prevented. We wished to estabilish an animal model in rat for a retrograde arterial flow based free flap. Nembutal-anesthetized male rats; weighing 250 to 300 gm, were used. The femoral artery and common carotid artery were exposed and divided. The systemic and retrograde arterial pressure were quantified by utilizing a parallel tubing system connected with peripheral arterial line. In this study, the retrograde flow was not pulsatile and the retrograde arterial pressure was 64-65mmHg, with a mean arterial pressure of 106-109mmHg. An epigastiic skin flap, measuring $3{\times}3cm$, was raised with its vascular pedicle. The epigastric free flap was transfered in the same rat from femoral vessels to carotid vessels in end to end fashion. We anastomosed the donor arteries to the distal parts of the divided recipient arteries and the donor veins to the proximal parts of the recipient veins. Twelve experiments were performed and the transplantations succeeded in 75 percent of them. In the remaining 25 percent, the experiments failed due to thrombosis at the site of anastpmosis, or other causes. This animal model represents an excellent example of retrograde arterial flow free flap transfer that is reliable.

  • PDF

근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교 (Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures)

  • 김재화;이윤석;안태근;최정필
    • Clinics in Shoulder and Elbow
    • /
    • 제11권2호
    • /
    • pp.143-149
    • /
    • 2008
  • 목적: 근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과를 비교 분석하고자 하였다. 대상 및 방법: 2003년부터 2007년 까지 본원에서 근위 상완골 골절로 입원하였던 87명의 환자중 금속판 고정술을 시행 받았던 환자 20명을 대상으로 하였으며 20명의 환자는 잠김 압박 금속판 고정을 시행하였던 환자 10명, 비잠김 금속판 고정을 시행하였던 환자 10명의 두 군으로 나뉘었다. 각각의 환자군은 수술 직후와 수술 후 6개월 뒤 방사선 사진상 상완골의 경간각, 골유합까지 소요된 시간, 합병증의 빈도 그리고 마지막 추시 당시의 Constant score를 측정하여 서로 비교 분석 하였다. 결과: 상완골의 경각간 및 골유합, Constant score에 대해서 두 군은 유의한 차이를 보이지 않았으나 비잠김 금속판을 사용한 군에서 나사 풀림 현상이 3례에서 발견되었다. 결론: 추시 결과상 잠김 압박 금속판의 사용이 비잠김 금속판에 비하여 임상적, 방사선학적으로 유의한 차이는 없었으나 근위 상완골 골절의 치료에서 나사 풀림 현상 등의 합병증이 적은 잠김 압박 금속판을 사용하는 것이 더 효과적일 것으로 사료된다.

골밀도를 이용한 대퇴근위부 형태 변화의 상관관계 평가 (Assessment of the Correlation for Geometry Transition using Bone Mineral Density in Proximal Femur)

  • 김다혜;고성진;강세식;김정훈;김동현;예수영;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.335-344
    • /
    • 2012
  • 우리나라는 급격한 경제성장과 의료기술의 발달로 고령화 사회가 되면서 골다공증 발병이 증가하고 있다. 또한 서구화된 식생활로 암질환이 증가하였고 항암치료과 방사선 치료 등으로 인해 골다공증이 발생하게 된다. 골다공증은 골밀도의 감소로 인한 것으로 대퇴근위부의 형태학적 구조 변화와도 밀접한 관계를 가지고 있으며, 대퇴 근위부의 형태학적 구조 변화는 고관절 골절의 위험을 나타내는 요인이다. 본 연구는 T-score변화에 따라 정상, 골감소증, 골다공증으로 분류하여 각 군별로 대퇴 근위부의 형태학적 변화를 관찰하고 상관관계를 분석하였다. 조사대상은 부산지역의 D종합병원의 남녀 350명을 대상으로 연령, 성별, T-score변화로 질환을 구분하여 분석하였다. 결과는 연령, 성별에 따라 골다공증의 발병빈도는 유의한 차이를 보였고, T-score변화에 따른 질환 분류와 대퇴근위부 형태학적 특성의 7가지 파라미터로서 Cortical ratio calcar, Cortical ratio shaft, Hip/shaft Angle, Strength index, Section modulus, CSMI, CSA는 유의한 차이를 보였으며 골다공증과 높은 상관관계가 있었다. 그러므로 연구 결과는 T-score변화에 따른 대퇴근위부의 형태학적 변화를 상관관계 분석함으로써 골다공증을 진단하는데 대퇴 근위부의 형태학적 변화가 지표로서 활용가능하리라 사료되며, 향후에 대퇴근위부의 형태학적 파라미터가 골다공증 진단의 정확성을 높이고 예측인자로서 임상활용이 가능하리라 판단된다.

개에서 원형외고정장치를 이용한 관절주위 골절의 안정화 (Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs)

  • 정혜련;김주호;차재관;설재원;김민수;이해범
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.523-526
    • /
    • 2014
  • 세마리의 개가 골절을 주증으로 내원하였다. 증례 1(1.8 kg의 5개월령 암컷 몰티즈)과 증례 2(3.0 kg의 6개월령 암컷 푸들)는 좌측 후지의 체중부중을 하지 않는 파행을, 증례 3(3.3 kg의 나이를 알 수 없는 암컷 잡종견)은 좌측 전지의 체중부중을 하지 않는 파행을 보였다. 정형외과 검사시 손상받은 부위의 통증, 염발음, 촉진상의 불안정성과 광범위한 연부조직 부종을 보였으며 신경학적 이상소견은 관찰되지 않았다. 방사선 검사상 증례 1와 2에서 좌측 근위 경골 골간단과 비골의 골절이, 증례 3에서는 좌측 근위 요골 골간단과 척골의 골절이 관찰되었다. 모든 증례는 골절편이 짧은 관절주위 폐쇄형 골절이었다. 술 중에는 투시장치를 이용해 2개 또는 3개의 원형고정장치의 적절한 위치에 삽입하였다. 술 후 방사선 사진에서 골절부위의 적절한 배열과 위치를 확인하였다. 방사선학적으로 5주에서 14주 사이에서 골유합이 확인되었고 임플란트의 고정 실패나 핀 주변 감염은 나타나지 않았다. 기능상 결과는 모든 증례에서 매우 좋은 것으로 나타났다. 따라서, 원형외고정장치는 뼈판이나 외고정장치를 사용할 수 없는 짧은 골절편을 가진 관절주의의 골절정복에 성공적으로 이용할 수 있을 거라 사료된다.