• Title/Summary/Keyword: Proximal fracture

Search Result 255, Processing Time 0.035 seconds

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN: THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST MOLAR (IPS Empress 도재관의 파절강도 : 상악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향)

  • Choi Teak-Rim;Lee Hae-Young;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.171-183
    • /
    • 2001
  • The purpose of this study was compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the upper first molar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and were cemented with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows: 1. The fracture strength of the ceramic crown with 2.5mm depth and $8^{\circ}$ inclination was the highest (1393N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (1015N) 2. There were no significant differences of the fracture strength according to occlusal depth and axial inclination. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth. 4. There was positive correlation between the fracture strength and the fracture surface area of crowns.

  • PDF

Partial Necrosis of the Mandibular Proximal Segment Following Transoral Vertical Ramus Osteotomy

  • Kim, Somi;Kim, Sang Yoon;Kim, Gi-Jung;Jung, Hwi-Dong;Jung, Young-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.131-134
    • /
    • 2014
  • Transoral vertical ramus osteotomy (TOVRO) procedure can result in a variety of complications. Complications commonly reported include extensive bleeding due to major blood vessel injury, unpredictable fracture, postoperative infection, neurosensory deficit related Inferior alveolar nerve, insufficient osteosynthesis, and temporomandibular joint problem. The authors describe a case of partial necrosis of the mandibular proximal segment following TOVRO, a rarely reported complication. A 37-year-old otherwise healthy woman underwent Lefort l osteotomy and TOVRO to correct mandibular prognathism. Postoperatively, she developed pain and swelling in the right submandibular region and was found to have a partial necrosis of proximal segment.

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN:THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST PREMOLAR CROWNS (IPS Empress 도재관의 파절강도 : 상악제1소구치에서 교합면 두께와 축면 경사도에 따른 영향)

  • Dong, Jin-Keun;Oh, Sang-Chun;Kim, Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.127-133
    • /
    • 1999
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the upper first premolar. After 10 metal dies were made fir each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results were : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (630N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength(378N). There were no significant differences of the fracture strength by axial inclination in same occlusal depth group. 2. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth.

  • PDF

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.

The Short Term Clinical Follow-up Study for Hemiarthroplasty in Proximal Humeral Fracture (상완골 근위부 분쇄 골절에서의 상완골 두 치환술의 단기 추시 결과)

  • Sung, Chang-Meen;Cho, Se-Hyun;Jung, Soon-Taek;Hwang, Sun-Chul;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.92-98
    • /
    • 2007
  • Introduction: The treatment of proximal humeral fracture is traditionally determined by Neer's classification system. The severely displaced three-part or four-part fracture is an indication for primary hemiarthroplasty. The current authors report the clinical results of 10 patients who received hemiarthroplasty for proximal comminuted fractures. The minimum follow-up period was 12 months. Materials and Methods: The current authors studied 10 patients who, between July 1999 and March 2005, each received hemiarthroplasty for a proximal humeral fracture of one shoulder. According to Neer's classification system, 5 of the patients had three-part fractures, and 5 of the patients had 4-part fractures. The mean interval between trauma and hemiarthroplasty was 6.1 days. The mean age of the 6 female and 4 male patients was 67.4 years(range: 56 to 76). Shoulder function was evaluated using the Constant score, the Simple Shoulder Test, and the modified UCLA score. Results: The mean Constant score was 51.4(range: 34 to 60). The mean modified SST score was 7.8 out of 12 tasks. Excluding the one patient who had also sustained an axillary artery rupture and a brachial plexus injury after the initial trauma, the mean Constant score for the remaining 9 patients was 53.5(range: 44 to 60), and the mean SST score was 7.2 tasks. The modified UCLA score averages for pain, function, and active forward flexion and strength were, respectively, 8.2($6{\sim}10$), 6.6($2{\sim}8$), and 6.9($4{\sim}8$). The total UCLA score was an average of 21.7($12{\sim}26$). Patients' the modified UCLA ratings were as follows: Excellent: 3, Good: 6, and Poor: 1. The patient with the poor outcome was the one who had also sustained the neurovascular injury. Patient's subjective satisfaction rating were as follows: Excellent: 2, Good: 7, and Poor: 1. Conclusion: Based on short term follow-up results, this study indicates that hemiarthroplasty is the treatment of choice for proximal humeral fractures on which it would be difficult to perform open reduction and internal fixation. Hemiarthroplasty is a useful treatment modality to prevent shoulder stiffness and to allow daily living tasks in elderly patients. However, restoration of muscle power and range of joint motion were not recovered satisfactorily.

The Usefulness of the Artificial Nail for Treatment of Fingertip Injuries (손가락끝 손상의 치료 시 인조손톱의 유용성)

  • Choi, Hwan-Jun;Kwon, Joon-Sung;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.788-794
    • /
    • 2010
  • Purpose: The fingertip is the most commonly injured part of the hand and its injury frequently results in avulsion or crushing of a segment of the nail bed and fracture of the distal phalangeal bone. Restoration of a flat and smooth nail bed is essential for regrowth of a normal nail, which is important not only for cosmetic reasons but also for tactile capability of the fingertip. It is also anatomical reduction of the distal phalanx to promote patient's cosmetics and prevent nail bed deformity. Absence or no replacement of the nail plate results in obliterated proximal skin fold. When the avulsed nail plate cannot be returned to its anatomic position or when it is absent, we use a synthetic material for splinting the nail bed and alternative reductional method for distal phalangeal bone fracture, especially, instead of hardwares. Methods: From January of 2006 to June of 2009, a total of ten patients and fourteen fingers with crushing or avulsion injuries of the fingertip underwent using the artificial nails for finger splint. We shaped artificial nails into the appropriate sizes for use as fingernail plates. We placed them under the proximal skin fold and sutured to the fold proximally and to the lateral and medial edges of the nail bed or to the distal fingertip. Our splints were as hard as K-wire and other fixation methods and more similar to anatomic nail plates. Artificial nails were kept in place for at least 3 weeks. Results: No artificial nail related complication was noted in any of the ten cases. No other nail fold or nail bed complications were observed, except for minor distal nail deformity because of trauma. Conclusion: In conclusion, in order to secure the nail bed after injury and reduce the distal phalangeal bone fracture, preparing a nail bed splint from a artificial commercial nail is a cheap and effective method, especially, for crushed or avulsion injuries of the fingertip.

Management of gunshot wounds near the elbow: experiences at a high-volume level I trauma center

  • Umar Ghilzai;Abdullah Ghali;Aaron Singh;Thomas Wesley Mitchell;Scott A. Mitchell
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.3-10
    • /
    • 2024
  • Background: Gunshot-related fractures near the elbow are challenging, and available data to guide the practitioner are lacking. This report analyzes injury patterns and treatment strategies in a case series from a high-volume urban trauma center. Methods: All periarticular gunshot fractures near the elbow treated at a level 1 trauma center from 2014 to 2018 were retrospectively reviewed. Fracture location, patient demographics, concomitant injuries, treatment modalities, and complications were analyzed. Results: Twenty-four patients were identified. All patients received prophylactic antibiotics upon admission and underwent urgent surgical debridement. Open reduction and internal fixation (ORIF) was performed with initial debridement in 22 of 24 patients. Seven patients sustained distal humerus fractures, 10 patients sustained isolated proximal ulna or proximal radius fractures, and seven had combined fracture patterns. Eleven patients presented with nerve palsy, and two had transected nerves. Two patients had vascular injury requiring repair. One patient required a temporary elbow-spanning external fixator and underwent staged debridement followed by ORIF. One patient with a grade IIIC fracture developed a deep infection that precluded ORIF. One patient required revision ORIF due to fracture displacement. Conclusions: This investigation reports on management of ballistic fractures near the elbow at a busy urban level I trauma center. Our management centered on rapid debridement, early definitive fixation, and intravenous antibiotic administration. We report on associated neurovascular injury, bone loss, and other challenges in this patient population. Level of evidence: IV.

AN EXPERIMENTAL STUDY ON THE FRACTURE STRENGTH OF CLASS II POSTERIOR RESTORATIONS (II급 와동에서 각종 구치용 수복물의 파절강도에 관한 실험적 연구)

  • Lee, Kye-Hyuck;Hur, Seung-Myun;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.357-367
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture strength of class II restored premolars with amalgam, posterior composite, amalgam - Ketac silver, resin - Ketac silver restorations at marginal ridge. Fifty extacted maxillary and mandibular premolar teeth that were caries free, fracture free, and restoration free were selected and randomly divided into five groups : Group 1 : 10 intact teeth, Group 2 : 10 teeth with class II cavities and restored with, amalgam, Group 3: 10 teeth with class II cavities and restored with posterior resin, Group 4 : 10 teeth with class II cavities and restored with amalgam - ketac silver, Group 5 : 10 teeth with class II cavities and restored with resin - Ketac silver. All teeth were mounted in base of dental stone within metal rings of 2cm diameter, exposing only the crown portion. Class II mesio - occlusal or disto - occlusal cavities were prepared into specimens of Group 2 through 5 by using a No. 710 fissure bur. The occlusal portion was prepared to a faciolingual width of 1.5mm and a pulpal depth of 1.5mm. The proximal protion was prepared to a faciolingual width of 4mm, a occlusogingival height of 4mm, and a gingival floor of 1.5mm. The teeth in Group 2 and 3 were resotored with silver amalgam apd posterior resin respectively. In Group 4 and 5, proximal portions were first filled with Ketac silver 1.5mm gingivally and remaining cavities were restored with amalgam and posterior resin respectively. All specimens were stored in 100 % relative humidity at $37^{\circ}C$ for 48 hours before testing. All teeth were subjected to a compressive load in a Universal Instron Testing Machine at marginal ridges. The loads required to fracture the restorations were recorded in killograms and the data obtained were subjected to statisticall analysis. The results were all follows : 1. The fracture strength of Group 1 which were unprepared were $100{\pm}10.1\;kg$ and the higher values than Group 2, 3, 4, 5 which were prepared and resotred. 2. In restored groups, Group 2 had the higher fracture strength($81.8{\pm}12.4\;kg$) than other groups and Group 4 had the lowest fracture strength($66.8{\pm}9.2kg$). 3. There were significant differences between fracture strength of between Group 1 and Group 3, 4, 5(P<0.05), but not significant difference between fracture strength of Group 2, 3, 4, 5(P>0.05).

  • PDF

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.