• 제목/요약/키워드: Provisional denture

검색결과 44건 처리시간 0.026초

Transitional implant를 이용한 임시수복과 최종 수복 (CLINICAL APPLICATION OF TRANSITIONAL IMPLANTS)

  • 김유리;민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권6호
    • /
    • pp.575-580
    • /
    • 2005
  • Transitional implants were developed to support provisional restorations and to allow for load-free osseointegration of conventional implants while a patient was provided with immediate esthetics and function and are usually placed simultaneously at the time of definitive implant placement. Transitional implants are placed in a non-submerged fashion in a single-stage surgery and are designed to be immediately loaded. They generally are made of commercially pure titanium or titanium alloy and are designed as 1-piece implants composed of root and crown replacement segments. Transitional implants can be used in a wide range of indications, such as basic use as temporary implant, to support and protect the primary implants during the healing phase, single crown in the edentulous anterior region of mandibular, anchorage for orthodontic treatment, support a surgical and radiographic template, and primary implant to extremely atrophied alveolar crests of the mandible and maxilla. This article describes the clinical use of transitional implants to support the provisional complete denture and single crown in the restricted edenturous central incisor region of mandible.

IN VITRO STUDY ON EXOTHERMIC REACTION OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS MEASURED BY DIFFERENTIAL SCANNING CALORIMETRY

  • Ko, Mun-Jeung;Pae, Ahran;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.690-698
    • /
    • 2006
  • Statement of problems. The heat produced during polymerization of polymer-based provisional materials may cause thermal damage to the vital pulp. Purpose. This study was performed to evaluate the exotherm reaction of the polymerbased provisional materials during polymerization by differential scanning calorimetry and to compare the temperature changes of different types of resins. Material and methods. Three dimethacrylate-based materials (Protemp 3 Garant, Luxatemp Plus, Luxatemp Fluorescence) and five monomethacrylate- based material (Snap, Alike, Unifast TRAD, Duralay, Jet) were selected. Temperature changes of polymer-based provisional materials during polymerization in this study were evaluated by D.S.C Q-1000 (TA Instrument, Wilmington, DE, USA). The following three measurements were determined from the temperature versus time plot: (1) peak temperature, (2) time to reach peak temperature, (3) heat capacity. The data were statistically analyzed using one-way ANOVA and multiple comparison Bonferroni test at the significance level of 0.05. Results. The mean peak temperature was $39.5^{\circ}C({\pm}\;1.0)$. The peak temperature of the polymer-based provisional materials decreased in the following order: Duralay > Unifast TRAD, Alike > Jet > Luxatemp Plus, Protemp 3 Garant, Snap, Luxatemp Fluorescence. The mean time to reach peak temperature was 95.95 sec $({\pm}\;64.0)$. The mean time to reach peak temperature of the polymer-based provisional materials decreased in the following order: Snap, Jet > Duralay > Alike > Unifast TRAD > Luxatemp Plus, Protemp 3 Garant, Luxatemp Fluorescence. The mean heat capacity was 287.2 J/g $({\pm}\;107.68)$. The heat capacity of the polymer-based provisional materials decreased in the following order: Duralay > TRAD, Jet, Alike > Snap, Luxatemp Fluorescence, Protemp 3 Garant, Luxatemp Plus. Conclusion. The heat capacity of materials, determined by D.S.C., is a factor in determining the thermal insulating properties of restorative materials. The peak temperature of PMMA was significantly higher than others (PEMA, dimethacrylate). No significant differences were found among PEMA (Snap) and dimethacrylate (P >0.05). The time to reach peak temperature was greatest with PEMA, followed by PMMA and dimethacrylate. The heat capacity of PMMA was significantly higher than others (PEMA, dimethacrylate). No significant differences were found among PEMA and dimethacrylate (P >0.05).

THE EFFECT OF MONOMER TO POWDER RATIO ON POLYMERIZATION SHRINKAGE-STRAIN KINETICS OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS

  • Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.735-742
    • /
    • 2007
  • Statement of problem. Although a number of previous investigations have been carried out on the polymerization shrinkage-strain kinetics of provisional crown and fixed partial denture (FPD) materials, the effect of the changes of liquid monomer to powder ratio on its polymerization shrinkage-strain kinetics has not been reported. Purpose. The purpose of this study was to investigate the influence of liquid monomer to powder ratio of polymer-based provisional crown and FPD materials on the polymerization shrinkage-strain kinetics. Material and methods. Chemically activated acrylic provisional materials (Alike, Jet, Snap) were investigated. Each material was mixed with different liquid monomer to powder ratios by volume (1.0:3.0, 1.0:2.5, 1.0:2.0, 1.0:1.5, 1.0:1.0). Time dependent polymerization shrinkage- strain kinetics of all materials was measured by the bonded-disk method as a function of time at $23^{\circ}C$. Five recordings were taken for each ratio. The results were statistically analyzed using one-way ANOVA and the multiple comparison Scheffe test at the significance level of 0.05. Trends were also examined by linear regression. Results. At 5 minutes after mixing, the polymerization shrinkage-strains of all materials ranged from only 0.01% to 0.49%. At 10 minutes, the shrinkage-strain of Alike was the highest, 3.45% (liquid monomer to powder ratio=1.0:3.0). Jet and Snap were 2.69% (1.0:2.0) and 1.58% (1.0:3.0), respectively (P>0.05). Most shrinkage (94.3%-96.5%) occurred at 30 minutes after mixing for liquid monomer to powder ratio, ranging from 1.0:3.0 to 1.0:1.0. The highest polymerization shrinkage-strain values were observed for the liquid monomer to powder ratio of 1.0:3.0. At 120 minutes after mixing, the shrinkage-strain values were 4.67%, 4.18%, and 3.07% for Jet, Alike, and Snap, respectively. As the liquid monomer to powder ratio increased, the shrinkage-strain values tend to be decreased linearly (r=-0.769 for Alike, -0.717 for Jet, -0.435 for Snap, $r^2=0.592$ for Alike, 0.515 for Jet, 0.189 for Snap; P<0.05). Conclusion. The increase of the liquid monomer to powder ratio from 1.0:3.0 to 1.0:1.0 had a significant effect on the shrinkage-strain kinetics of polymer-based crown and FPD materials investigated. This increased the working time and decreased the shrinkage-strain during polymerization.

상악 전치부 고정성 보철물 수복 시 임시 임플란트를 이용한 임시보철물의 유지력 증가 증례보고 (Reinforcing the retention of provisional restoration using provisional implant on maxillary anterior region: clinical case report)

  • 김창대;문홍석;정문규;이재훈
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.221-225
    • /
    • 2013
  • 임시 보철물의 적절한 관리는 보철의 성공에 있어서 중요한 요소이다. 상악 전치 결손부 임시 보철물은 장경간의 결손부가 존재하거나, 타원형의 악궁을 가진 환자에서 자주 탈락하게 된다. 이는 상악 전치부가 구치부에 비해서 수평적인 힘에 더 많이 노출되며, 부가적으로 전방 캔틸레버 효과가 임시 보철물의 유지를 저해하고, 상악 전치부 임시 보철물은 하악의 기능 운동시 적절한 전방 유도를 제공하여야 하기 때문이다. 또한 임시 보철물의 최대 감합위에서 교합접촉은 지점선의 반대편에 위치하게 되어 그 자체로 임시 보철물의 탈락을 야기한다. 본 증례에서는 임시 임플란트를 이용하여 상악 전치부 보철물에 대한 전술한 유해 작용을 피할 수 있었고, 발치 후 치유기간 동안 환자에게 편안함과 만족감을 부여하였으므로 이를 보고하는 바이다.

주조 금속 구조물을 이용하여 강화한 임시보철물 수복 증례 (Reinforcement of provisional restoration with cast metal framework: A case report)

  • 김현영;문윤희;이종혁
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.46-52
    • /
    • 2017
  • 임시보철물은 고정성 보철물로의 수복 과정에서 지대치 보호 및 기능과 심미성 회복의 측면에서 중요한 역할을 수행한다. 특히 이를 장착한 상태로 최종 수복 전에 장기간의 관찰이 필요한 환자에서 그 중요성이 더욱 강조되나, 상대적으로 낮은 강도로 인하여 잦은 파절이 발생할 수 있으며 이를 방지하기 위해 강화된 임시보철물의 제작을 고려할 수 있다. 이 문헌에서는 교합 수직 고경의 증가를 필요로 하는 환자의 증례를 소개하고자 하였으며, 수직 고경 증가의 영향으로 임시보철물 사용 시 더 큰 부하의 작용 및 장기간의 사용이 예상되었다. 이에 주조 금속 하부구조물을 첨가하여 bis-acryl 레진으로 강화된 임시보철물을 제작하였으며, 약 4개월의 관찰 기간 동안 만족스러운 결과를 보였다.

Full mouth rehabilitation of destroyed dentition with rotational path removable partial denture: a case report

  • Kim, Moon-Hyoung;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.46-49
    • /
    • 2010
  • BACKGROUND. Though implant dentistry is very successful and predictable in treatment of patients with destroyed dentition, there are some cases with limitations to implant therapy. In these cases, alternative treatment modality should be considered. CASE DESCRIPTION. A patient with destroyed dentition was rehabilitated with a lateral rotational path removable partial denture. According to the diagnosis, we determined to raise vertical dimension for esthetic and functional restoration. The final restoration was performed after four months of provisional period. CLINICAL IMPLICATION. The edentulous patients with compromised esthetics and functions can be successfully treated with a rotational path removable partial denture through adequate treatment planning and precise laboratory procedure.

골수염 치료로 인해 골결함이 있는 부분무치악 환자에서 IARPD 수복 (Restoration of IARPD in partially edentulous patients with bone defects due to osteomyelitis treatment)

  • 박세현;성한결;고경호;허윤혁;박찬진;조리라
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.359-369
    • /
    • 2021
  • 다수의 치아를 상실한 부분무치악 환자의 치료방법으로는 임플란트 고정성 보철물과 가철성 국소의치가 주로 이용되며, 최근에는 골흡수가 심한 부분무치악 환자에서 의치의 유지와 안정을 위해 임플란트를 추가적으로 이용하는 임플란트 보조 국소의치(implant-assisted removable partial denture, IARPD)를 전략적으로 선택하게 된다. 안면골 감염의 일종인 골수염으로 인한 악안면 구조의 상실은 저작, 연하, 발음과 같은 기능장애 및 사회적, 심리적인 영향을 유발하므로 상실된 조직회복을 위해 가철성 수복이 필요하고 지대치와 국소의치의 설계가 치료의 성공에 더욱 중요한 역할을 담당한다. 이 경우 전통적인 가철성 국소의치에 비해 높은 유지력과 안정성을 가지는 IARPD는 좋은 예후를 보일 수 있다. 본 증례는 골수염 치료로 인해 골결함이 있는 부분무치악 환자에서 IARPD 수복으로 의치의 안정성을 확보하고, 여러 차례에 걸친 임시수복을 통해 적절한 의치 설계와 교합양식을 부여함으로써 최종적으로 발생할 수 있는 문제점을 최소화하고 장기적으로 양호한 예후를 기대할 수 있기에 이를 보고하는 바이다.

상악 임플란트 피개의치에서 임플란트 보조 국소의치로의 전환: 증례보고 (Conversion of implant overdenture to an implant assisted removable partial denture in maxilla: case report)

  • 조성수;송민규;허윤혁;박찬진;조리라;고경호
    • 대한치과보철학회지
    • /
    • 제62권1호
    • /
    • pp.54-63
    • /
    • 2024
  • 장기간 사용된 임플란트 피개의치는 부착장치의 마모와 전치부 교합집중, 인공치 파절, 의치의 회전 등을 보일 수 있다. 이러한 문제점은 추가적인 임플란트 식립을 이용한 임플란트보조 국소의치(IARPD, implant assisted removable partial denture)로의 전환으로 개선할 수 있다. 본 증례는 임플란트 피개의치를 사용하는 3급 악간관계 환자에서 전치부에 집중된 교합을 분산하고 의치의 회전방지를 위해 서베이드 크라운을 이용한 IARPD으로 전환하였다. 여러 단계의 임시수복물을 통해 적절한 기능과 심미를 가진 최종보철물의 형태를 결정하였으며 최종 보철물의 적절한 구치부 교합과 임플란트 주위 변연골 유지를 보였기에 이를 보고하는 바이다.

Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report

  • Hong, Jun-Won;Ahn, Seung-Geun;Leem, Dae-Ho;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.52-56
    • /
    • 2012
  • Conventional implant protocols required a load-free healing period of three to six months between placement and functional loading of the implants. Many efforts have been made to minimize the duration of treatment time. Several literatures have documented immediate function with provisional or definitive prosthesis within a week of the placement in response to these demands. In addition, immediate implant placement has advantages such as shortened treatment time and preservation of soft tissue architectures. This article presents immediate implant placement into fresh extraction sockets followed by functional immediate loading with provisional prosthesis on canine and premolars for a patient having canine protected occlusion.

열형성 기술을 활용한 임시 의치 수복 증례 (The case of interim denture applying for thermoforming technique)

  • 윤준구;송영균
    • 구강회복응용과학지
    • /
    • 제32권2호
    • /
    • pp.135-140
    • /
    • 2016
  • 사고로 인하여 갑자기 치아를 상실하게 된 환자에게 정신적 안정, 심미성과 기능을 회복하기 위하여 빠른 임시 보철물 수복이 필요하다. 본 증례는 외상으로 인하여 예상치 못한 치아 상실이 발생한 환자에게 열형성 기술(thermoforming technique)을 이용한 수복을 시행하여 만족할 만한 결과를 얻었기에 보고하는 바이다.