CURRENT RESEARCH ON ACCELERATOR-BASED BORON NEUTRON CAPTURE THERAPY IN KOREA

  • Kim, Jong-Kyung;Kim, Kyung-O
    • Nuclear Engineering and Technology
    • /
    • 제41권4호
    • /
    • pp.531-544
    • /
    • 2009
  • This paper is intended to provide key issues and current research outcomes on accelerator-based Boron Neutron Capture Therapy (BNCT). Accelerator-based neutron sources are efficient to provide epithermal neutron beams for BNCT; hence, much research, worldwide, has focused on the development of components crucial for its realization: neutron-producing targets and cooling equipment, beam-shaping assemblies, and treatment planning systems. Proton beams of 2.5 MeV incident on lithium target results in high yield of neutrons at relatively low energies. Cooling equipment based on submerged jet impingement and micro-channels provide for viable heat removal options. Insofar as beam-shaping assemblies are concerned, moderators containing fluorine or magnesium have the best performance in terms of neutron accumulation in the epithermal energy range during the slowing-down from the high energies. NCT_Plan and SERA systems, which are popular dose distribution analysis tools for BNCT, contain all the required features (i.e., image reconstruction, dose calculations, etc.). However, detailed studies of these systems remain to be done for accurate dose evaluation. Advanced research centered on accelerator-based BNCT is active in Korea as evidenced by the latest research at Hanyang University. There, a new target system and a beam-shaping assembly have been constructed. The performance of these components has been evaluated through comparisons of experimental measurements with simulations. In addition, a new patient-specific treatment planning system, BTPS, has been developed to calculate the deposited dose and radiation flux in human tissue. It is based on MCNPX, and it facilitates BNCT efficient planning based via a user-friendly Graphical User Interface (GUI).

Improvement of accuracy in radioactivity assessment of medical linear accelerator through self-absorption correction in HPGe detector

  • Suah Yu;Na Hye Kwon;Sang-Rok Kim;Young Jin Won;Kum Bae Kim;Se Byeong Lee;Cheol Ha Baek;Sang Hyoun Choi
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2317-2323
    • /
    • 2024
  • Medical linear accelerators with an energy of 8 MV or higher are radiated owing to photonuclear reactions and neutron capture reactions. It is necessary to quantitatively evaluate the concentration of radioactive isotopes when replacing or disposing them. HPGe detectors are commonly used to identify isotopes and measure radioactivity. However, because the detection efficiency is generally calibrated using a standard material with a density of 1.0 g/cm3, a self-absorption effect occurs if the density of the measured material is high. In this study, self-absorption correction factors were calculated for tungsten, lead, copper, and SUS-303, which are the main materials of medical linear accelerator head parts, for each gamma-ray energy using MCNP 6.2 code. The self-absorption effect was more pronounced as the energy of the emitted gamma rays decreased and the density of the measured materials increased. These correction factors were applied to the radioactivity measurements of the in-built and portable HPGe detectors. Furthermore, compared to the surface dose rate measured by the survey meter, the accuracy of the measurements of radioactivity improved by an average of 124.31 and 100.53 % for inbuilt and portable HPGe detectors, respectively. The results showed a good agreement, with an average difference of 3.70 and 5.24 %.

양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가 (Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy)

  • 이승현;장요종;김태윤;정도형;최계숙
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.107-114
    • /
    • 2012
  • 목 적: 기존의 광자선을 이용한 선형가속기와는 달리, 양성자 치료의 경우 물질과의 상호작용으로 발생되는 중성자를 비롯한 여러 핵종 등으로 인해 다량의 이차방사선이 생성되기 때문에 방사선 작업 종사자의 피폭은 더욱 주의 깊은 관심이 필요하다. 이에 방사선 측정 시에 널리 이용되고 있는 열형광선량계를 이용하여 방사선 작업 종사자의 피폭정도를 평가하고 이를 토대로 양성자 치료 시 방사선 피폭선량에 관한 기초 자료를 제시하고자 한다. 대상 및 방법: 본원의 양성자 치료실에서 근무한 방사선 작업 종사자를 대상으로 열형광선량계 뱃지를 이용해 피폭현황을 측정한 데이터를 비교했다. 양성자의 빔 라인 주변에서 발생하는 이차방사선의 신체부위별 피폭선량 분포를 알아보고자 신체부위(외안각, 목, 유두점, 배꼽, 등, 손목)에 가로, 세로가 각각 3 mm인 정사각형 모양의 열형광선량계를 부착하여 일일 8시간의 근무시간동안 유지하도록 하였고 총 80시간 측정하여 평균 데이터를 얻었다. 그리고 치료실 내 공간적인 방사선량의 분포를 보기 위하여 빔 사출구, PPS (Patient Positioning System), Pendant, 차폐체보관장, DIPS (Digital Image Positioning System) Console, 출입통로에 각각 열형광선랑계를 부착하고 일일 근무시간 동안의 평균 방사선량을 측정하였다. 결 과: 방사선 작업 종사자의 열형광선량계 뱃지로 측정된 피폭량을 조사한 결과 분기별 평균 0.174 mSv, 연평균 0.543 mSv로 나타났고 신체부위별로 측정한 결과에서 가장 많은 피폭량을 보인 곳은 목이였으며 가장 적은 피폭량을 보인 곳은 등(양견갑골 상각을 이은 선의 중간 지점)으로 나타났다. 작업 동선에 따른 공간적 방사선량을 알아본 결과에서는 빔 사출구 근처에서 상대적으로 높게 나타났고 거리가 멀어짐에 따라 줄어들었다. 결 론: 적은 양의 피폭일지라도 동일 장소에서 장기 근무하게 되면 피폭 누적량은 증가할 수밖에 없고 특정 부위의 누적량은 건강상의 위험을 가져다 줄 수도 있다. 그러므로 국제 방사선 방어 위원회가 권고하는 ALARA의 원칙에 따라 가능한 합리적으로 감소시킬 수 있도록 스스로 개인별 피폭관리에 철저를 기하고 피폭을 최소화시키는데 최선의 노력을 다해야 할 것이다.

  • PDF

100 MeV 양성자가속기를 이용한 27Al(p,3p+n)24Na 핵반응에 대한 감마선 스펙트럼 측정 (Measurement of Gamma ray Spectrum for the 27Al(p,3p+n)24Na Nuclear Reaction by using 100 MeV Proton Acceleration System)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제9권1호
    • /
    • pp.55-59
    • /
    • 2015
  • 양성자핵반응에 대한 연구는 현재 핵융합로의 재료 개발을 비롯하여 양성자치료 분야 등을 중심으로 활발하게 이루어지고 있다. 본 연구는 100 MeV 양성자 빔을 이용한 $^{27}Al(p,3p+n)^{24}Na$ 반응을 통하여 발생되는 지발 감마선(2754, 1386 keV) 스펙트럼을 고순도 HPGe 검출기를 이용하여 측정하였다. 실험에 사용되어진 양성자 빔은 양성자가속기연구센터(KOMAC)에 설치되어 있는 100 MeV 양성자선형가속기를 사용하였다. 측정된 감마선은 기존에 알려진 결과들과 비교분석하였다. 측정된 감마선의 강도는 고에너지 감마선 검출효율을 결정하는데 매우 중요한 정도를 제공 할 것으로 생각되어 진다.

Conceptional design of an adjustable moderator for BNCT based on a neutron source of 2.8 MeV proton bombarding with Li target

  • Yinan Zhu;Zuokang Lin;Haiyan Yu;Xiaohan Yu;Zhimin Dai
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1813-1821
    • /
    • 2024
  • Beam shaping assembly (BSA) is a vital component in Boron Neutron Capture Therapy (BNCT) for obtaining epithermal neutron beams. Several feasible designs of BSA for accelerator-based BNCT (AB-BNCT) neutron source are carried out based on neutrons by bombarding a natural lithium target with 10 mA, 2.8 MeV proton beams. The calculation results demonstrate that a thickness of 45 cm is appropriate for general moderators referring to the therapeutic parameter of Advanced Depth (AD). A series of optimizations are performed and two results are confirmed: One is that employing the configuration of MgF2 and FLUENTAL combined by 1:1 could improve the therapeutic rate (TR) of tumors at a depth of middle region, and the other one is that the TR of superficial tumors can be increased by adding a 5 cm thick boron-11 secondary moderator at the end of general moderators. As a result, an innovative conception of an adjustable moderator is recommended to BNCT. Compared to the MgF2 moderator with a fixed thickness of 45 cm, the TR value can be improved by a maximum of 47.7 % by using the adjustable moderator. Furthermore, the configuration of adjustable moderator has been designed with regulation method for treating tumors of different depths.

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • 제33권4호
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

두경부환자 고정기구제작을 통한치료기 가동범위에 관한 고찰 (Consideration about LINAC movable range by H&N patient immobilization device manufacture)

  • 정도형;심진섭;염두석;최계숙
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.63-67
    • /
    • 2004
  • 목적 : 방사선치료가 발전함에 따라 3D-CRT나 IMRT 등의 새로운 치료기법이 등장하게되었다. 이러한 치료법은 여러 방향의 방사선조사를 필요로 한다. 그러나 지금의 선형가속기만으로는 사실상 여러 방향의 방사선조사에 많은 제약이 따른다. 본원에서는 이러한 장치적제한을 극복하고 궁극적으로 다양한 방향의 선속을 이용함으로서 선량분포를 개선하고자 두경부고정장치를 제작하였다. 이에 기존의 고정장치에 비해 치료기의 가동범위가 얼만큼 효율적으로 개선되었는지를 정량적으로 측정하여 조사하였다. 대상 및 방법 : 선형가속기 Couch에 기존의 고정장치를 놓고 Gantry를 각각 $45^{\circ},\;90^{\circ},\;135^{\circ}$에서 고정시키고 Couch를 돌려 장비의 clearance를 확인한다. 또한 Couch를 $0^{\circ},\;45^{\circ},\;90^{\circ}$에서 고정시키고 Gantry의 clearance를 확인한 후 제작된 Extended Head Holder(EHH)를 Couch에 부착하고 다시 앞에서 시행한 방법과 동일한 과정을 반복함으로서 EHH부착 후의 Gantry와 Couch사이의 clearance의 개선여부를 확인한다. 결과 : Gantry를 고정하고 Couch를 회전시켜본 결과 $45^{\circ}$에서는 큰 차이가 없었으나 $90^{\circ},\;135^{\circ}$로 각도가 커질수록 EHH를 사용한 경우 Couch의 가동범위가 커지는 것으로 나타났으며, Couch를 고정시키고 Gantry를 회전시킨 경우는 $45^{\circ}$에서 EHH를 사용한 경우가 사용하지 않을 경우보다 가동범위가 크게 나타나는 것을 볼 수 있었고 $0^{\circ}$$90^{\circ}$에서는 모두다 양호한 가동상태를 보여주었다. 또한 방사선의 후방조사시 EHH의 사용으로 Couch의 frame에 의한 방사선 감쇄를 막을 수 있었다. 결과 : 두경부환자의 치료 시 환자고정기구(EHH)를 제작하여 사용함으로서 보다 많은 방향에서 방사선조사가 가능해지고 이로 인해 보다나은 치료계획을 세울 수 있게 되었으며, 치료장비의 회전에 따른 장비와 환자사이 또는 장비와 장비사이의 안전공간이 보다 많이 확보될 수 있었다. 그리고 외국의 제품에 비해 저렴한 가격으로 제작이 가능하였고 또한 치료소모품의 절약을 가져올 수가 있게 되었다.

  • PDF

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

방사선 치료의 국내 현황과 미래 (Present Status and Future Aspects of Radiation Oncology in Korea)

  • 허승재
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.211-216
    • /
    • 2006
  • 목 적: 최근 국내 방사선 치료의 발전 경향, 시설 장비와 인적 현황 등 인프라와 특징을 조사하고, 국내 방사선종양학분야의 발전 방향을 모색하려 한다. 대상 및 방법: 2006년도 방사선종양학과 전공의 지도 감독에 관한 실태 조사를 위하여 2006년 7월, 전문의, 전공의, 의학 물리사, 간호사, 방사선사 등 인력 및 치료 장비 인프라 조사와 함께 향후 확장 계획에 관한 조사를 실시하였다. 국내 61개 기관의 치료 시설 등급 결정은 IAEA 조사연구에서 사용한 기준에 따라서 분류하였다. 결 과: 2006년 7월 현재 한국에 설치된 방사선종양학과는 61개 병원이며, 132명의 전문의와 50명의 전공의를 포함하여 선량계산사 및 의학물리사 64명, 방사선사 369명 간호사 130명 등 745명의 인력이 2004년도 기준으로 28,789명 신환의 방사선치료 업무를 담당하고 있다. 방사선치료기는 메가볼티지 치료기가 104대 설치되어 있고 선형가속기가 96대, 코발트 원격치료기 2대, 토모치료기 3대, 사이버나이프가 2대, 한 대의 양성자 치료기가 설치되어 있다. 강내치료 장치는 41개 병원에 설치되어 있으며 이 중 35개 병원에서 고선량률 강내치료기, 6개 병원에서 저선량률 강내치료 장치가 설치 운영되고 있다. 국내 61개 병원의 IAEA기준에 따른 분류에서는 level 0이 2곳, level 1이 15곳, level 2가 19곳이고, level 3 즉 강도조절 방사선치료, 정위적 방사선치료, 수술 중 방사선치료가 가능한 시설이 25곳으로 매우 높은 질의 치료를 시행함을 보여준다. 결 론: 최근 치료시설과 방사선치료 관련 인적 인프라는 현저한 증가 추세에 있다. 즉, 선형가속기의 증가와 함께 코발트 치료기는 현격한 감소를 보이며 토모치료기, 사이버나이프 등 첨단 치료 장치가 증가하는 경향이다. 한국의 메가볼티지 치료기의 숫자는 인구 백만 명당 2.1대로서 향후 방사선치료의 필요성과 적응증이 계속 증가되는 추세에 있어서 치료기의 증가가 필요한 실정이다.

한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션 (Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON)

  • 배재범;조병철;곽정원;박우윤;임영경;정현태
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.12-17
    • /
    • 2015
  • 본 연구에서 한국형 중이온 가속기 RAON에서의 의생물 실험을 위하여 요구되는 빔 조건을 만족할 수 있도록 Monte Carlo 전산모사를 통한 노즐 설계를 최적화하고자 하였다. 의생명 실험을 위한 빔 조건으로 최대 조사면 크기, 선량균일도 그리고 빔 오염도의 특정 조건을 만족하는 $C^{12}$ 빔 생산이 요구되었다. 이때 최적화된 빔 노즐 설계를 위하여 Monte Carlo 시뮬레이션인 GEANT4 toolkit이 사용되었다. $15{\times}15cm^2$ 이상의 빔 조사면 크기와 3% 이내의 선량 균일도 그리고 전체 선량의 5% 보다 낮은 빔 오염도를 기본적인 조건으로 설정 되었다. 조사면 크기는 쌍극자 자석에 의해서 빔의 각도를 기울여 원형으로 회전하면서 쌍극자 자석의 아래쪽에 위치한 산란판의 두께를 조정하여 최적화 하였다. 빔 스캐닝 각도와 산란판의 두께는 Monte Carlo 시뮬레이션 분석에 의해서 각각 $0.5^{\circ}$와 0.05 cm로 최적의 값을 나타내었다. 선량 균일도와 최대 조사면 크기를 만족하기 위하여 static과 scanning beam을 복합하는 기술을 이용한 새로운 빔 전달 방법을 소개하였다. 중앙 고정용 빔과 빔 축으로부터 $0.5^{\circ}$ 경사각을 가지고 회전하는 빔과 경사각이 없이 바로 들어오는 빔을 조합하여 선량균일도가 1.1%와 빔 조사면의 최대크기가 $15{\times}15cm^2$가 되는 것을 확인하였다. 빔 오염도는 $C^{12}$ 이온과 다른 입자들에 의해서 전달된 흡수선량의 비율로 나타내었다. 물등가 깊이(water equivalent depth) 5 cm에서 17 cm 사이에서의 빔 오염도는 전체 선량에서의 2.5% 미만임을 확인하였으며 이와 같은 결과를 바탕으로, 본 연구에서는 의생명 실험을 위하여 요구되는 빔 조건을 만족하는 노즐 구조를 설정할 수 있었다.