• Title/Summary/Keyword: Proton dose distribution

검색결과 52건 처리시간 0.024초

Bi-material Bolus for Minimizing the Non-uniformity of Proton Dose Distribution

  • Takada, Yoshihisa;Kohno, Syunsuke
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.214-215
    • /
    • 2002
  • Generally uniform dose distribution is assumed to be formed in a target region when a conventional dose formation method using a broad proton beam, a fixed modulation technique, a bolus and an aperture is employed. However, actual situations differ. We usually find non-uniformity in the target region. This is due to the insertion of a range-compensating bolus before the patient. Since the range-compensating bolus has an irregular shape, the scattering in the bolus depends on the lateral position. Dose distribution is overlapping results of dose distribution of pencil-proton beams traversing different lateral positions of the bolus. The lateral extent of dose distribution of each pencil beam traversing the different position differs each other at the same depth in the target object. This is a cause of the non-uniformity of the dose distribution. Therefore the same lateral extent of dose distribution should be attained for different pencil beams at the same depth to obtain a uniform dose distribution. For that purpose, we propose here a bi-material bolus. The bi-material bolus consists of a low-Z material determining mainly the range loss and a high-Z material defining mainly the scattering in the bolus. After passing through the bi-material bolus, protons traversing different lateral positions will have different residual range yet with the same lateral spread at a certain depth. Using the optimized bi-material bolus, we can obtain a more uniform dose distribution in the target region as expected.

  • PDF

Particle-based simulation of proton therapy for QA

  • Yasuoka, Kiyoshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.69-72
    • /
    • 1999
  • We present a method of quality assurance (QA) for dose and dose distribution anticipated in treatment planning at proton therapy using a particle-based simulation method.

  • PDF

즉발감마선을 이용한 양성자 빔 위치 측정에 관한 연구 (Determination of Proton Beam Position Based on Prompt Gamma Ray Detection)

  • 서규석;김종원;김찬형
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.69-71
    • /
    • 2004
  • 양성자 치료는 양성자 빔의 선량분포 특성인 브래그 피크를 이용한 방사선 치료방법으로 기존의 전자 및 광자빔을 이용하는 방사선 치료와 비교하여 정상세포에는 현저히 적은 선량을 주고, 암세포에는 대부분의 선량을 줄 수 있어 최근에 각광받고 있다. 양성자 치료 빔은 치료 부위에서 완전히 멈추고 인체 내 각기 다른 밀도를 가진 장기들에 의해 양성자 빔의 비정이 불확실하기 때문에 체내 양성자 빔의 분포를 확인하고 빔을 조정하면서 치료할 수 있는 적절한 방법이 없다. 양성자 빔의 물질에 대한 흡수선량 분포와 물질과 양성자의 핵반응으로 방출되는 즉발 감마선의 상관관계를 이용한 측정시스템을 몬테칼로 전산코드로 전산모사하고 계산한 결과 체내 양성자 빔의 위치를 실시간으로 측정할 수 있음을 확인하였다.

  • PDF

Experimental Evaluation of Proton Dose Calculations in Phantoms Simulating a Clinical Heterogeneity in Patients

  • Kohno, Ryosuke;Takada, Yoshihisa;Sakae, Takeji;Terunuma, Toshiyuki;Matsumoto, Keiji;Nohtomi, Akihiro;Matsuda, Hiroyuki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.208-210
    • /
    • 2002
  • In a treatment planning for actual patients with a complex internal structure, we often expect that proton beams, which pass through both a bolus and the heterogeneity in body, will form complex dose distributions. Therefore, the accuracy of the calculated dose distributions has to be verified for such a complex object. Then dose distributions formed by proton beams passing through both the bolus and phantoms simulating a clinical heterogeneity in patients were measured using a silicon semiconductor detector. The calculated results by the range-modulated pencil beam algorithm (RMPBA) produced large errors compared with the measured dose distributions since dose calculation using the RMPBA could not predict accurately the edge-scattering effect both in the bolus and in clinical heterogeneous phantoms. On the other hand, in spite of this troublesome heterogeneity, calculated results by the simplified Monte Carlo (SMC) method reproduced the experimental ones well. It is obvious that the dose-calculations by the SMC method will be more useful for application to the treatment planning for proton therapy.

  • PDF

양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구 (Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification)

  • 이한림;민철희;박종훈;김성훈;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.162-168
    • /
    • 2012
  • 양성자 치료에서 치료의 목표를 달성하고 환자의 안전을 제고하기 위해 인체 내 양성자 빔의 분포를 확인하는 것이 중요하다. 양성자 선량분포와 밀접한 관계가 있는 즉발감마선의 2차원 분포 측정을 위하여 본 연구팀에서는 다수의 CsI(Tl) 섬광체가 1차원 종형으로 배열된 검출기 배열과 집속장치 및 다채널 신호처리 장치로 이루어진 측정장치를 개발하고 있다. 이에 본 연구에서 몬테칼로 기반의 MCNPX 코드를 이용하여 최적화된 측정 장치를 설계하고자 하였다. 즉발감마선을 효과적으로 측정하기 위해 CsI(Tl) 섬광체의 크기를 $6{\times}6{\times}50mm^3$로 결정하였으며, 배경감마선의 영향을 최소화하고 빔의 진행방향에서 수직방향으로 발생하는 즉발감마선만 측정하기 위해 집속장치의 구멍 크기는 면적 $6{\times}6mm^2$, 길이 150 mm로 최적화되었다. 150 MeV 양성자 빔에 대한 성능 예측 전산모사연구를 수행한 결과, 본 연구에서 최적화된 측정 장치를 통해 즉발감마선 2차원 분포를 측정할 수 있었으며, 1 mm 오차범위에서 양성자 빔의 비정을 결정할 수 있었다. 이를 바탕으로 현재 다채널의 신호처리 장치를 개발하고 있으며 실제 양성자 빔을 이용한 즉발감마선 분포측정을 통해 측정 장치의 성능을 검증할 것이다.

Linear Energy Transfer Dependence Correction of Spread-Out Bragg Peak Measured by EBT3 Film for Dynamically Scanned Proton Beams

  • Lee, Moonhee;Ahn, Sunghwan;Cheon, Wonjoong;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.135-144
    • /
    • 2020
  • Purpose: Gafchromic films for proton dosimetry are dependent on linear energy transfers (LETs), resulting in dose underestimation for high LETs. Despite efforts to resolve this problem for single-energy beams, there remains a need to do so for multi-energy beams. Here, a bimolecular reaction model was applied to correct the under-response of spread-out Bragg peaks (SOBPs). Methods: For depth-dose measurements, a Gafchromic EBT3 film was positioned in water perpendicular to the ground. The gantry was rotated at 15° to avoid disturbances in the beam path. A set of films was exposed to a uniformly scanned 112-MeV pristine proton beam with six different dose intensities, ranging from 0.373 to 4.865 Gy, at a 2-cm depth. Another set of films was irradiated with SOBPs with maximum energies of 110, 150, and 190 MeV having modulation widths of 5.39, 4.27, and 5.34 cm, respectively. The correction function was obtained using 150.8-MeV SOBP data. The LET of the SOBP was then analytically calculated. Finally, the model was validated for a uniform cubic dose distribution and compared with multilayered ionization chamber data. Results: The dose error in the plateau region was within 4% when normalized with the maximum dose. The discrepancy of the range was <1 mm for all measured energies. The highest errors occurred at 70 MeV owing to the steep gradient with the narrowest Bragg peak. Conclusions: With bimolecular model-based correction, an EBT3 film can be used to accurately verify the depth dose of scanned proton beams and could potentially be used to evaluate the depth-dose distribution for patient plans.

이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발 (Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution)

  • 박종훈;이한림;김찬형;김성훈;김성훈;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.42-51
    • /
    • 2015
  • 양성자 치료 시 양성자 빔을 사용하여 정밀한 치료를 수행하고 환자의 안전을 제고하기 위해서는 인체 내 양성자 빔의 선량 분포를 확인하는 것이 중요하다. 이를 위해 본 연구팀은 이전 연구에서 1차원 배열형 검출기를 종형으로 배치하여 빔 진행방향으로 이동시켜가면서 2차원적인 즉발감마선 분포를 측정하여 양성자 선량 분포와 유사한 분포를 갖는 것을 확인하였다. 본 연구에서는 이를 바탕으로 즉발감마선 이차원분포를 실시간으로 측정하기 위해 이차원 평행다공형 집속 장치, 이차원 배열의 NaI(Tl) 섬광체와 MA-PMT로 이루어진 즉발감마선 이차원분포 측정 장치를 개발하였다. 개발한 즉 발감마선 이차원분포 측정 장치의 성능을 평가한 결과 $^{22}Na$ 감마선원의 에너지 분해능은 $10.9%{\pm}0.23p%$ (0.511 MeV)와 $6.4%{\pm}0.24p%$ (1.275 MeV)로 평가되었으며, $^{137}Cs$$9.8%{\pm}0.18p%$ (0.662 MeV)로 평가되었다. 고에너지 Am-Be 선원의 double escape 피크인 3.416 MeV의 에너지 분해능은 $11.4%{\pm}3.6p%$로 평가되었다. 본 측정 장치를 이용하여 45 MeV 양성자 빔을 PMMA에 조사하여 발생한 즉발감마선 이차원분포를 측정한 결과 0.5 nA의 세기의 양성자 빔에서 $9{\times}10^9$ 양성자 조사 시 양성자 선량 분포와 유사한 즉발감마선 이차원분포를 측정할 수 있음을 확인하였다. 추가로 측정한 즉발감마선 이차원분포의 프로파일 분포를 이용하여 양성자 빔의 비정을 평가해 본 결과 $17.0{\pm}0.4mm$로 평가되었고, 실제 비정인 17.4 mm과 굉장히 밀접한 관련이 있음을 확인하였다.

양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구 (Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case)

  • 김재원;심진섭;장요종;강동윤;최계숙
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.47-51
    • /
    • 2010
  • 목 적: 고 에너지 양성자치료에 있어서 Air gap (환자와 Beam 사출구 사이의 거리)의 변화는 Lateral Penumbra의 증가로 불필요한 조사야를 형성할 수 있고, 치료부위에서 최대선량 증가와 최소선량 감소로 선량분포의 균질성을 저하시킬 수 있다. 이에 Air gap 변화에 따른 선량분포에 대해 비교, 연구해 보고자 한다. 대상 및 방법: 본원에서 양성자치료를 받은 Lung, Liver 환자 6명을 선정하여 크기가 다른 조사야 A와 조사야 B에서 Air gap을 2, 4, 6, 8, 10 cm로 설정하여 Proton external beam planning system을 통해 치료계획을 세웠다. Air gap에 따른 Lateral Penumbra 영역 및 DVH (Dose Volume Histogram)를 비교하고 PCTV영역의 최대선량 및 최소선량 값을 비교하였다. 또한 PCTV내에 선량의 균질성을 알기 위하여 Homogeneity index값을 비교, 분석하였다. 결 과: 각각의 조사야에서 Air gap의 변화(2, 4, 6, 8, 10 cm)에 따른 Lateral Penumbra영역을 분석한 결과 조사야 A에서 Air gap 2~10 cm변화에 따라 평균 1.36~1.75 cm까지 약 28.7%가 지속적으로 증가하였고 조사야 B에서 평균 1.36~1.79 cm까지 약 31.6%가 지속적으로 증가하였다. DVH를 분석한 결과 최대선량의 상대선량 백분율은 Air gap 2~10 cm일 때 평균 108.1%에서 평균 110.3%까지 약 2.03%가 지속적으로 증가하였고 최소선량의 상대선량 백분율은 평균 93.9%에서 평균 90.8%까지 약 3.31%가 지속적으로 감소하였다. Homogeneity index값은 평균 Air gap 2~10 cm까지 1.09~2.6으로 2배 이상 증가하였다. 결 론: 양성자 치료에 있어서 Air gap이 증가함에 따라 Lateral Penumbra 영역이 증가함을 알 수 있었고, 치료부위에서 최대선량 값의 증가와 최소선량 값의 감소로 인하여 Homogeneity index값이 증가함으로써 PCTV내에 Beam의 균질성이 떨어지는 것을 알 수 있었다. 이에 추후 양성자치료시 Air gap을 줄이기 위한 노력이 필요할 것으로 사료된다.

  • PDF

Off-line PET-CT를 이용한 양성자치료에서의 Range 검증 (Analysis of the Range Verification of Proton using PET-CT)

  • 장준영;홍건철;박세준;박용철;최병기
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.101-108
    • /
    • 2017
  • 목 적: 양성자치료에 이용되는 양성자선은 종양 부위 앞에 있는 정상 조직에는 적은 선량을 주는 반면 암 조직 부위에서는 브래그 피크(Bragg peak)를 형성하며 최대 선량을 주고 바로 소멸하는 특징을 가지고 있으며 양성자치료의 장점을 극대화하기 위해서는 양성자의 도달 위치 검증이 매우 중요하다. 본 연구에서는 Off-line PET CT 방법을 이용하여 양성자 조사 후 양성자 궤적을 따라 생성된 11 C(반감기=20분), 150(반감기=2분), 13N (반감기=10분) 등의 핵자에서 방출되는 양전자의 분포를 측정하여 양성자의 Range와 Distal falloff 지점을 검증하게 되었다. 대상 및 방법: IEC 2001 Body 팬텀안에는 37 mm, 28 mm, 22 mm 구체를 삽입할 수 있게 구성되어 있으며 팬텀안에 물을 가득 채워 각 구체크기별로 CT image를 획득하였고 양성자의 Range와 Distal falloff 지점을 검증하기 위하여 양성자치료계획시스템으로 각 구체 크기 별로 37 mm 구체에서 46 mm, 28 mm에서 37 mm, 22 mm 구체에서 33 mm의 SOBP를 설정하였고, Scanning 방법으로 Gantry 0도의 Single beam으로 동일한 센터에서 양성자를 조사하였다. 조사된 팬텀은 PET-CT 장비를 이용하여 스캔하였고, PET-CT 영상획득방법은 1분씩 50개의 영상을 획득하여 팬톰 내의 구체를 포함하여 4개의 ROI를 설정한 후 10개씩 영상을 합산하여 재구성 하였다. 치료계획 시 수립한 구체크기에 따른 Dose profile과 비교하기 위하여 Depth에 따른 Activity profile로 나타냈다 결 과: 37 mm, 28 mm, 22 mm 구체에서 모두 Distal falloff position 에서 Dose profile과 같이 PET-CT의 Activity profile 역시 급격히 감소하는 양상을 나타냈다. 하지만 Range를 평가하는 구간인 SOBP구간에서는 Activity profile의 경우 Proximal 부분에서의 측정치가 Dose profile 양상과 다른 결과가 나왔으며, Distal falloff position을 구체 크기별로 양성자 치료계획과 PET-CT 측정치와의 차이를 비교해 본 결과 37 mm 구체에서는 Max dose의 50 % 지점에서 최대 1.4 mm, 28 mm 구체에서는 45 % 지점에서 최대 1.1 mm, 22 mm 구체에서의 차이는 40 % 지점에서 최대 1.2 mm로 모두 1.5 mm 미만의 차이를 보였다. 결 론: 양성자치료의 장점을 최대한 활용하기 위해서는 양성자빔의 Range를 검증하는 것이 매우 중요하다. 본 연구에서는 PET-CT 장비를 이용하여 양성자빔의 SOBP 와 Distal falloff 위치를 통해 양성자 Range를 확인하였고 그 결과 PET-CT 장비를 이용해 측정한 Activity 분포와 양성자 치료계획과의 Distal falloff position의 차이는 1.4 mm 내에서 일치함을 확인하였다. 이는 본원에서 양성자치료계획 시 적용하는 선량마진에 참고자료로 활용될 수 있을 것으로 사료된다.

  • PDF

몬테카를로 시뮬레이션을 이용한 양성자 조사에 따른 Polymer Gel 내부의 선량 분포 특성 평가 (Estimation of the Characteristics for the Dose Distribution in the Polymer Gel by Means of Monte Carlo Simulation)

  • 박민석;김기섭;정해조;박세영;최인석;김현지;윤용수;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권2호
    • /
    • pp.165-173
    • /
    • 2013
  • 본 연구는 몬테카를로 시뮬레이션을 이용하여 양성자 빔을 피사체에 조사했을 때 발생되는 양성자, 즉발감마선 그리고 양성자 유발 중성자의 3차원적 공간분포를 polymer gel 선량계를 통해 구하고, 이를 물 팬텀에서 조사한 결과와 비교하여 3차원적 선량 분포의 정확성에 대해 알아보고자 한다. 본 연구에서 사용 된 polymer gel 선량계는 Gelatin, Methacrylic acid, Hydroquinone, Tetrakis 그리고 증류수로 이루어진 혼합물로 그 밀도는 $1.04g/cm^3$으로 물의 밀도인 $0.9998g/cm^3$과 유사하다. 본 시뮬레이션에서는 72 MeV, 116 MeV, 140 MeV 의 양성자 빔이 사용되었다. 양성자 빔은 팬텀의 핵과 반응을 하고 양성자 빔으로 인해 여기된 핵이 다시 안정하게 되기 위해 즉발감마선 그리고 양성자 유발 중성자를 방출한다. 양성자와 즉발감마선 그리고 양성자 유발 중성자는 polymer gel 선량계와 물 팬텀에서 각각 검출하였다. 3차원적 선량 분포를 얻기 위한 검출 간격은 2 mm로 하여 선량 분포를 획득하였다. Polymer gel 선량계에서의 양성자의 Bragg-peak를 구해 본 결과 Bragg-peak 지점이 물 팬텀에서의 경우와 유사하게 나타남을 확인 할 수 있었다. 72 MeV, 116 MeV, 그리고 140 MeV의 양성자 빔을 polymer gel 그리고 물 팬텀에 조사했을 때 그 내부에서의 양성자 그리고 즉발감마선의 선량 분포는 polymer gel, 물 팬텀 각각 유사한 선량분포를 가짐을 감마 인덱스 평가로 확인 할 수 있었다. 하지만 양성자 유발 중성자의 경우 물 팬텀에서는 검출이 된 반면 polymer gel 선량계에서는 검출이 되지 않았다. Polymer Gel 선량계는 3차원적 선량 분포를 얻는데 유용한 선량계이지만 양성자 조사 시 그 유발 중성자의 검출에는 한계를 보임을 확인할 수 있었다.