• Title/Summary/Keyword: Protocols

Search Result 4,019, Processing Time 0.034 seconds

Normal Predictive Values of Spirometry in Korean Population (한국인의 정상 폐활량 예측치)

  • Choi, Jung Keun;Paek, Domyung;Lee, Jeoung Oh
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.3
    • /
    • pp.230-242
    • /
    • 2005
  • Background : Spirometry should be compared with the normal predictive values obtained from the same population using the same procedures, because different ethnicity and different procedures are known to influence the spirometry results. This study was performed to obtain the normal predictive values of the Forced Vital Capacity(FVC), Forced Expiratory Volume in 1 Second($FEV_1$), Forced Expiratory Volume in 6 Seconds($FEV_6$), and $FEV_1/FVC$ for a representative Korean population. Methods : Based on the 2000 Population Census of the National Statistical Office of Korea, stratified random sampling was carried out to obtain representative samples of the Korean population. This study was performed as a part of the National Health and Nutrition Survey of Korea in 2001. The lung function was measured using the standardized methods and protocols recommended by the American Thoracic Society. Among those 4,816 subjects who had performed spirometry performed, there was a total of 1,212 nonsmokers (206 males and 1,006 females) with no significant history of respiratory diseases and symptoms, with clear chest X-rays, and with no significant exposure to respiratory hazards subjects. Their residence and age distribution was representative of the whole nation. Mixed effect models were examined based on the Akaike's information criteria in statistical analysis, and those variables common to both genders were analyzed by regression analysis to obtain the final equations. Results : The variables affecting the normal predicted values of the FVC and $FEV_6$ for males and females were $age^2$, height, and weight. The variables affecting the normal predicted values of the $FEV_1$ for males and females were $age^2$, and height. The variables affecting the normal predicted values of the $FEV_1/FVC$ for male and female were age and height. Conclusion : The predicted values of the FVC and $FEV_1$ was higher in this study than in other Korean or foreign studies, even though the difference was < 10%. When compared with those predicted values for Caucasian populations, the study results were actually comparable or higher, which might be due to the stricter criteria of the normal population and the systemic quality controls applied to the whole study procedures together with the rapid physical growth of the younger generations in Korea.

Cytotoxic Effects of Tenebrio molitor Larval Extracts against Hepatocellular Carcinoma (갈색거저리 유충 추출물의 간암세포에 대한 세포독성 효능)

  • Lee, Ji-Eun;Lee, An-Jung;Jo, Da-Eun;Cho, Ju Hyeong;Youn, Kumju;Yun, Eun-Young;Hwang, Jae-Sam;Jun, Mira;Kang, Byoung Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.2
    • /
    • pp.200-207
    • /
    • 2015
  • Various natural products or their derivatives, mostly originating from plants, fungi, and bacteria, have been exploited as therapeutic drugs to treat various human diseases. In addition to previously explored organisms, research on natural compounds has now expanded into unexamined living organisms in order to identify novel bioactive substances. Here, we determined whether or not the larval form of the mealworm beetle Tenebrio molitor, a species of darkling beetle, contains cytotoxic substances that exclusively affect cancer cell viability. Ethanol extract and its solvent partitioned fractions, hexane and ethyl acetate fractions, showed anticancer effects against various human cancer cells derived from the prostate (PC3 and 22Rv1), cervix (HeLa), liver (PLC/PRF5, HepG2, Hep3B, and SK-HEP-1), colon (HCT116), lung (NCI-H460), breast (MDA-MB231), and ovary (SKOV3). Cell death induced by the fractions was a mix of apoptosis, necrosis, and autophagy. The hexane fraction was administered intraperitoneally to nude mice bearing a hepatocellular carcinoma SK-HEP-1 and showed inhibition of tumor growth in vivo. Therefore, we concluded that worm extracts contain cytotoxic substances, which can be enriched by proper fractionation protocols, and further separation and purification could lead to the identification of novel molecules to treat human cancers.

Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease (관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성)

  • Lee, Duk-Young;Bae, Jin-Ho;Lee, Sang-Woo;Chun, Kyung-Ah;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Ha, Jeoung-Hee;Chae, Shung-Chull;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.473-480
    • /
    • 2005
  • Purpose: Adenosine myocardial perfusion SPECT has proven to be useful in the detection of coronary artery disease, in the follow up the success of various therapeutic regimens and in assessing the prognosis of coronary artery disease. The purpose of this study is to define the reproducibility of myocardial perfusion SPECT using adenosine stress testing between two consecutive Tc-99m sestaMIBI (MIBI) SPECT studies in the same subjects. Methods: Thirty patients suspected of coronary artery disease in stable condition underwent sequential Tc-99m MIBI SPECT studies using intravenous adenosine. Gamma camera, acquisition and processing protocols used for the two tests were identical and no invasive procedures were performed between two tests. Mean interval between two tests were 4.1 days (range: 2-11 days). The left ventricular wall was divided into na segments and the degree of myocardial tracer uptake was graded with four-point scoring system by visual analysis. Images were interpretated by two independent nuclear medicine physicians and consensus was taken for final decision, if segmental score was not agreeable. Results: Hemodynamic responses to adenosine were not different between two consecutive studies. There were no serious side effects to stop infusion of adenosine and side effects profile was not different. When myocardial uptake was divided into normal and abnormal uptake, 481 of 540 segments were concordant (agreement rate 89%, Kappa index 0.74). With four-grade storing system, exact agreement was 81.3% (439 of 540 segments, tau b=0.73). One and two-grade differences were observed in 97 segments (18%) and 4 segments (0.7%) respectively, but three-grade difference was not observed in any segment. Extent and severity scores were not different between two studios. The extent and severity scores of the perfusion defect revealed excellent positive correlation between two test (r value for percentage extent and severity score is 0.982 and 0.965, p<0.001) Conclusion: Hemodynamic responses and side effects profile were not different between two consecutive adenosine stress tests in the same subjects. Adenosine Tc-99m sestaMIBI SPECT is highly reproducible, and could be used to assess temporal changes in myocardial perfusion in individual patients.

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

A Modified Protocol for Myocardial Perfusion SPECT Using Natural Plant Extracts for Enhancement of Biliorg Excretion (담즙분비촉진 식물추출물을 이용한 심근관류영상 검사법 개선)

  • Jeong, Hwan-Jeong;Kim, Chang-Guhn
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.364-373
    • /
    • 2003
  • Purpose: For good quality of myocardial perfusion images, an approximately 30 min to 1 hour of waiting time after radiopharmaceutical injection and ingestion of fatty meal are asked of the patients. The aim of this study was to investigate the shortening of waiting time after radiopharmaceutical injection and improvement of image quality using natural plant extracts that promote bile excretion. Materials and Methods: Ten volunteers participated in protocol 1 (7 men, 3 women; mean age, $24.1{\pm}2.4$ years) and protocol 2 (8 men, 2 women; mean age, $26.1{\pm}2.9$ years), respectively. For the modified method of both protocols, subjects took natural plant extracts 15 minutes before the first injection of $^{99m}Tc$ MIBI without laking fatty meals. Control (Conventional) methods were peformed with intake of a fatty meal 20 to 30 minutes after $^{99m}Tc$ MIBI injection. Results: As the results of protocol 1 and 2, the ratio of myocardial to lung ratio were not different between modified and conventional method. Liver to lung ratio of modified method showed significantly lower value than that of conventional method. In modified method, myocardial to liver ratio was higher persistently. In protocol 2, natural plant extracts took before the first injection of $^{99m}Tc$ MIBI exerted accelerating effect of excretion of bile juice into Intestine until the end of examination. Conclusion: These results represent that natural plant extracts for facilitation of bile excretion before injection of $^{99m}Tc$ MIBI may provide better quality of myocardial perfusion images without the need for preparations such as ingestion of fatty meal within the 2 hours compared with conventional method.

$V_H$ Gene Expression and its Regulation on Several Different B Cell Population by using in situ Hybridization technique

  • Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.6 no.2
    • /
    • pp.111-122
    • /
    • 1993
  • The mechanism by which $V_H$ region gene segments is selected in B lymphocyte is not known. Moreover, evidence for both random and nonrandom expression of $V_H$ genes in matured B cells has been presented previously. In this report, the technique of in situ hybridization allowed us to analyze expressed $V_H$ gene families in normal B lymphocyte at the single cell level. The analysis of normal B cells in this study eliminated any posssible bias resulting from transformation protocols used previously and minimized limitation associated with sampling size. Therefore, an accurate measure of the functional and expressed $V_H$ gene repertoire in B lymphocyte could be made. One of the most important controls for the optimization of in situ hybridization is to establish probe concentration and washing stringency due to the degree of nucleotide sequence similarlity between different families which in some cases can be as high as 70%. When the radioactive $C{\mu}$ and $V_{H}J558$ RNA probes are tested on LPS-stimulated adult spleen cells, $2{\sim}4{\times}106cpm$/slide shows low background and reasonable frequency of specific positive cells. For the washing condition. 40~50% formamide at $54^{\circ}C$ is found to be optimum for the $C{\mu}$. $V_{H}S107$ and $V_{H}J558$ probes. The analyzed results clearly demonstrate that the level of each different $V_H$ gene family expression is dependent upon the complexity or size of that family. These findings are also extended to the level of $V_H$ gene family expression in separated bone marrow B cells depend upon the various stage of differentiation and conclude no preferential utilization of specific $V_H$ gene family. Thus, the utilization of VH gene segments in B lymphocyte of adult BALB/c mice is random and is not regulated or changed during the differentiation of B cells.

  • PDF

Effects of electromagnetic stimulation on neurogenesis and neuronal proliferation in rat hippocampal slice culture (실험 쥐 해마조직배양에서 전자기 자극이 신경조직발생 및 증식에 미치는 영향)

  • Kim, Deok-Soo;Choi, Eung Sang;Chae, Soo Ahn
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.5
    • /
    • pp.558-564
    • /
    • 2006
  • Purpose : Transcranial electromagnetic stimulation(TMS) is a noninvasive method which stimulates the central nervous system through pulsed magnetic fields without direct effect on the neurons. Although the neurobiologic mechanisms of magnetic stimulation are unknown, the effects on the brain are variable according to the diverse stimulation protocols. This study aims to observe the effect of the magnetic stimulation with two different stimulation methods on the cultured hippocampal slices. Methods : We obtained brains from 8-days-old Spague-Dawley rats and dissected the hippocampal tissue under the microscope. Then we chopped the tissue into 450 µm thickness slices and cultured the hippocampal tissue by Stoppini's method. We divided the inserts, which contained five healthy cultured hippocampal slices respectively, into magnetic stimulation groups and a control group. To compare the different effects according to the frequency of magnetic stimulation, stimulation was done every three days from five days in vitro at 0.67 Hz in the low stimulation group and at 50 Hz in the high stimulation group. After N-methyl-D-aspartate exposure to the hippocampal slices at 14 days in vitro, magnetic stimulation was done every three days in one and was not done in another group. To evaluate the neuronal activity after magnetic stimulation, the $NeuN/{\beta}$-actin ratio was calculated after western blotting in each group. Results : The expression of NeuN in the magnetic stimulation group was stronger than that of the control group, especially in the high frequency stimulation group. After N-methyl-D-aspartate exposure to hippocampal slices, the expression of NeuN in the magnetic stimulation group was similar to that of the control group, whereas the expression in the magnetic non-stimulation group was lower than that of the control group. Conclusion : We suggest that magnetic stimulation increases the neuronal activity in cultured hippocamal slices, in proportion to the stimulating frequency, and has a neuroprotective effect on neuronal damage.