• 제목/요약/키워드: ProtocolMonitoring

검색결과 744건 처리시간 0.029초

Implementation of Real-Time Wireless Web Server Load Monitoring System

  • Park, Hong-Jin;Kwon, Chang-Hee
    • 한국디지털정책학회:학술대회논문집
    • /
    • 한국디지털정책학회 2004년도 International Conference on Digital Policy & Management
    • /
    • pp.211-219
    • /
    • 2004
  • Due to rapid increases in Internet users, it becomes essential to provide well-established web services and monitor web server's load for the sake of reliable web server management. The existing web server load monitoring has been based on such cable methods as RPC, RMI, CORBA and etc. But it has the limitation in bringing information both anywhere and anytime over the Internet. This thesis is aimed to realize real-time wireless web server monitoring system based on Wireless Application Protocol (WAP). As any user can log on wirelessly to the Internet at any time through wireless terminals like PDA, the realization will make possible instant and real-time web server monitoring.

  • PDF

통신망에서의 무니터링 프로세서의 성능분석 (Performance Analysis of Monitoring Processors of Communication Networks)

  • 이창훈;홍정식;이경태
    • 한국경영과학회지
    • /
    • 제18권1호
    • /
    • pp.45-54
    • /
    • 1993
  • Monitoring processor in a circuit switched network is considered. Monitoring processor monitors communication links offers a grade of service in each link to controller. Such an information is useful for an effective maintenance of system. Two links with asymmetric system parameters and multi-symmetric links are respectively considered. Each links is to be an independent M /M/ 1/ 1/ type. Markov modeling technique is used to represent a model of monitoring processor with FCFS steering protocol. Performance measures considered are ratio of monitored jobs in each link, availability of minitoring processor and throughput of virtual processor in each link. The value of the performance meausres are compared with existing and simulation results.

  • PDF

사용성을 고려한 IP-USN 기반 작업장 환경 모니터링 시스템 가이드라인 (User-Center Design of Workplace Environmental Monitoring Guideline)

  • 윤정민;신유민;박범
    • 한국IT서비스학회지
    • /
    • 제8권4호
    • /
    • pp.215-223
    • /
    • 2009
  • The workplace environment monitoring system based on IP-USN proposed in this study measures and analyzes workplace environment information so as to provide services to provide better work environment and prevent occupational accidents caused by poor, shabby labor environment. This study presents the procedures to design and develop a system that monitors noise, humidity, vibration, temperature, and sensors installed in the workplace and sounds alarm when workers enter dangerous areas or are exposed to hazards. The author actually installed the IP-USN workplace environment monitoring system in a small workplace and confirmed its effectiveness.

Multi-Modal Sensing M2M Healthcare Service in WSN

  • Chung, Wan-Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권4호
    • /
    • pp.1090-1105
    • /
    • 2012
  • A multi-modal sensing M2M healthcare monitoring system for the continuous monitoring of patients under their natural physiological states or elderly persons with chronic diseases is summarized. The system is designed for homecare or the monitoring of the elderly who live in country side or small rest home without enough support from caregivers or doctors, instead of patient monitoring in big hospital environment. Further insights into the natural cause and progression of diseases are afforded by context-aware sensing, which includes the use of accelerometers to monitor patient activities, or by location-aware indoor tracking based on ultrasonic and RF sensing. Moreover, indoor location tracking provides information about the location of patients in their physical environment and helps the caregiver in the provision of appropriate support.

임베디드 시스템들을 위한 SNMP 기반의 저부하 시스템 모니터링 (Low Overhead System Monitoring Based on SNMP for Embedded Systems)

  • 김태수;김동억;김용석
    • 전자공학회논문지CI
    • /
    • 제43권3호
    • /
    • pp.1-9
    • /
    • 2006
  • SNMP는 네트워크 장비들의 관리를 위한 표준 프로토콜이지만 요즘의 대부분의 컴퓨터 시스템들은 SNMP 에이전트로서의 기능을 보유하고 있다. 본 논문에서는 임베디드 시스템을 위한 저부하의 SNMP 라이브러리를 개발하고, 이를 활용하여 많은 수의 시스템들을 일괄적으로 모니터링하기 위한 소프트웨어를 구현하였다. 모니터링 시스템은 모니터링 서버, SNMP 에이전트들, 및 클라이언트 프로그램으로 구성된다. 모니터링 서버는 모니터링 대상 시스템에서 실행되는 SNMP 에이전트들로부터 상태정보들을 수집하고 요약 정보를 클라이언트 프로그램에게 전달한다. 클라이언트 프로그램은 Java를 활용한 독자적인 프로그램과 웹 기반의 프로그램의 두 가지 버전을 구현하였다.

PXA 270 기반 이동형 임베디드 시스템을 이용한 실내 환경 모니터링 (Indoor Environment Monitoring Using a PXA 270-based Mobile Embedded System)

  • 정구종;김인혁;손영익
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.249-251
    • /
    • 2009
  • Mobile patrol robots are mainly used in aerospace and military engineering because they can work at dangerous environment replacing a man. This paper presents a study on the remote monitoring and control system of a mobile patrol robot platform using TCP/IP. The mobile robot consists of intel PXA270 and linux-based system. It can get environment information such as images, temperature, humidity and slope by using two cameras and various sensors. And it transmits information data to a monitoring system through the ad-hoc network which is one of wireless network solutions. At this time, a mobile robot is a server and a monitoring system is a client. Users can monitor environment information which is received from a mobile robot by an application based on PC. We have used TCP/IP protocol, socket programming, interface technique of process and devices and control algorithm to embody the mobile robot and its monitoring system. Experimental results shows that the system can be utilized as a remote patrol monitoring tool.

  • PDF

전화모니터링이 심부전 환자의 증상경험과 자기관리 이행정도에 미치는 효과 (Effect of a Telephone Monitoring on Self-management & Symptom Experiences in Patients With Heart Failure)

  • 송은경
    • 성인간호학회지
    • /
    • 제17권1호
    • /
    • pp.56-67
    • /
    • 2005
  • Purpose: The main purpose of this study was to examine the effectiveness of a standardized telephone monitoring intervention in addressing the symptom experience and improving self-management ability in patients with heart failure. Methods: A non-equivalent control group pre-post test design was used. There were 17 patients in the experimental group, and 16 in the control group. According to the protocol, patients in the experimental group received 15 to 30 minute-telephone monitoring four times, once a week for 4 weeks. Data were analyzed by ${\chi}^2$-test, Mann-Whitney U test. Results: 1) The experimental group showed a significant increase in compliance with self-management compared to the control group. 2) There was a significant decrease in degree for 3 symptoms(DOE, PND, & continuing fatigue) in the experimental group, after telephone monitoring. However, the experimental group did not show significant decrease in the degree of the total symptom experiences. Conclusions: The results of this study provide evidence that standardized telephone monitoring is effective in relieving symptom experience and improving self-management in patients with heart failure over the course of telephone monitoring.

  • PDF

Full-scale bridge expansion joint monitoring using a real-time wireless network

  • Pierredens Fils;Shinae Jang;Daisy Ren;Jiachen Wang;Song Han;Ramesh Malla
    • Structural Monitoring and Maintenance
    • /
    • 제9권4호
    • /
    • pp.359-371
    • /
    • 2022
  • Bridges are critical to the civil engineering infrastructure network as they facilitate movement of people, the transportation of goods and services. Given the aging of bridge infrastructure, federal officials mandate visual inspections biennially to identify necessary repair actions which are time, cost, and labor-intensive. Additionally, the expansion joints of bridges are rarely monitored due to cost. However, expansion joints are critical as they absorb movement from thermal effects, loadings strains, impact, abutment settlement, and vehicle motion movement. Thus, the need to monitor bridge expansion joints efficiently, at a low cost, and wirelessly is desired. This paper addresses bridge joint monitoring needs to develop a cost-effective, real-time wireless system that can be validated in a full-scale bridge structure. To this end, a wireless expansion joint monitoring was developed using commercial-off-the-shelf (COTS) sensors. An in-service bridge was selected as a testbed to validate the performance of the developed system compared with traditional displacement sensor, LVDT, temperature and humidity sensors. The short-term monitoring campaign with the wireless sensor system with the internet protocol version 6 over the time slotted channel hopping mode of IEEE 802.15.4e (6TiSCH) network showed reliable results, providing high potential of the developed system for effective joint monitoring at a low cost.

Calibration of Portable Particulate Mattere-Monitoring Device using Web Query and Machine Learning

  • Loh, Byoung Gook;Choi, Gi Heung
    • Safety and Health at Work
    • /
    • 제10권4호
    • /
    • pp.452-460
    • /
    • 2019
  • Background: Monitoring and control of PM2.5 are being recognized as key to address health issues attributed to PM2.5. Availability of low-cost PM2.5 sensors made it possible to introduce a number of portable PM2.5 monitors based on light scattering to the consumer market at an affordable price. Accuracy of light scatteringe-based PM2.5 monitors significantly depends on the method of calibration. Static calibration curve is used as the most popular calibration method for low-cost PM2.5 sensors particularly because of ease of application. Drawback in this approach is, however, the lack of accuracy. Methods: This study discussed the calibration of a low-cost PM2.5-monitoring device (PMD) to improve the accuracy and reliability for practical use. The proposed method is based on construction of the PM2.5 sensor network using Message Queuing Telemetry Transport (MQTT) protocol and web query of reference measurement data available at government-authorized PM monitoring station (GAMS) in the republic of Korea. Four machine learning (ML) algorithms such as support vector machine, k-nearest neighbors, random forest, and extreme gradient boosting were used as regression models to calibrate the PMD measurements of PM2.5. Performance of each ML algorithm was evaluated using stratified K-fold cross-validation, and a linear regression model was used as a reference. Results: Based on the performance of ML algorithms used, regression of the output of the PMD to PM2.5 concentrations data available from the GAMS through web query was effective. The extreme gradient boosting algorithm showed the best performance with a mean coefficient of determination (R2) of 0.78 and standard error of 5.0 ㎍/㎥, corresponding to 8% increase in R2 and 12% decrease in root mean square error in comparison with the linear regression model. Minimum 100 hours of calibration period was found required to calibrate the PMD to its full capacity. Calibration method proposed poses a limitation on the location of the PMD being in the vicinity of the GAMS. As the number of the PMD participating in the sensor network increases, however, calibrated PMDs can be used as reference devices to nearby PMDs that require calibration, forming a calibration chain through MQTT protocol. Conclusions: Calibration of a low-cost PMD, which is based on construction of PM2.5 sensor network using MQTT protocol and web query of reference measurement data available at a GAMS, significantly improves the accuracy and reliability of a PMD, thereby making practical use of the low-cost PMD possible.

테이블 기반 알고리즘을 이용한 CRC8의 구현 (CRC8 Implementation using Direct Table Algorithm)

  • 서석배;김영선;박종억;공종필;용상순;이승훈
    • 항공우주기술
    • /
    • 제13권2호
    • /
    • pp.38-46
    • /
    • 2014
  • CRC (Cyclic Redundancy Codes)는 데이터 전송 시 오류 발생 유무를 검출하기 위한 하나의 방법으로, 정지궤도복합위성(GEO-KOMPSAT 2B) 개발에서는 정지궤도환경탑재체와 위성 간의 GRDDP (GOES-R Reliable Data Delivery Protocol)에 사용되고 있다. 본 논문에서는 CRC를 구현할 때 널리 사용하는 테이블 기반 CRC의 원리를 소개하고, 이를 기반으로 환경탑재체 개발에서 사용 중인 CRC8을 소프트웨어로 구현한 결과를 설명한다.