• Title/Summary/Keyword: ProtocolMonitoring

Search Result 747, Processing Time 0.028 seconds

Development and Performance Evaluation of the CAN Monitoring System (CAN 모니터링 시스템 개발 및 성능 평가)

  • 이원희;박민규;이민철;김동수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.60-60
    • /
    • 2000
  • CAN(Controller Area Network) is a serial communication protocol which specifies very low cost and high performance. It is widely used in rea1-time control applications such as automobiles, aircraft, and automated factories. The main application fields are industrial control systems and embedded network. In this paper, the CAN monitoring system is proposed and implemented. Also its performance is tested in the mobile robot which is integrated by CAN and its performance lot receipt failure rate is evaluated. This can be used to analyze the performance of the network. It can tie also used to manage and monitor the network.

  • PDF

A Study on Safety System for Blasting Workers using Real Time Location System in the Shipyard (선박용 블라스팅 셀 내에서의 실시간 위치 추적 기술을 이용한 작업자 안전 시스템에 대한 연구)

  • Yun, Won-Jun;Ro, Young-Shic;Cho, Sang-Bock
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.836-842
    • /
    • 2010
  • Safety system including location monitoring system for blasting workers was studied. Positioning performance of the location monitoring system was highly dependent on communication protocol and the number of access points in the blasting cell. RTLS(Real Time Location System) is an important technology to develop the location information of workers and variously used to enhance workers safety. Location monitoring system with Cell-ID and RSSI wireless communication technology was verified to have a proper positioning performance for the steel block application.

Guard Lamp using Solar Cell (태양광을 이용한 정원등)

  • Kang Byung-Bog;Cha In-Su;Lim Jung-Yeol;Yoon Jeong-Phil;Park Se-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.129-132
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-oncard based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generationplants, etc..

  • PDF

Implementation of the Monitoring System for Power Condition System(PCS) using a Smartphone and Bluetooth Communication (스마트폰과 블루투스 통신을 이용한 태양광 인버터 모니터링 시스템 구현)

  • Je, Hyun-Woo;Yang, Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2185-2191
    • /
    • 2012
  • The monitoring of the existing inverter is being implemented using a local computer of web monitoring, but in this paper, the remote monitoring system of the power condition system was implemented using a Bluetooth communication at a convenient position for the user that can be monitored without the computer. The proposed system was designed to be able to monitor the wanted information by using the protocol of inverter. Also when the power condition system has failed, the fault history and the generated time of inverter were stored in the Bluetooth device. Finally the performance of the proposed system was evaluated through experiments, it showed the good performance and the possibility of commercialization.

A Study on the Development for Environment Monitoring System of Micro Data Center (마이크로 데이터센터의 환경 모니터링 시스템 개발 연구)

  • Lee, Kap Rai;Kim, Young Sik
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.355-360
    • /
    • 2022
  • In this paper, we present design and developing method for EMS(environment monitoring system) of micro data center. This developing EMS monitors operating environment of micro data center and analyze sensing data through IoT(Internet of things) sensors in real time. Firstly we present configuration method of IoT sensing package and design method EMS hardware platform. Secondly we design data collector software for data collection of IoT sensor with different protocol and develop monitoring software of EMS. The data collector software consists of sensor collector module and collector manager module. Also we design EMS software which has micro service architecture structural style and component based business logic.

STN DBS of Advanced Parkinson's Disease Experienced in a Specialized Monitoring Unit with a Prospective Protocol

  • Lee, Ji-Yeoun;Han, Jung-Ho;Kim, Han-Joon;Jeon, Beom-Seok;Kim, Dong-Gyu;Paek, Sun-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.26-35
    • /
    • 2008
  • Objective : In the evaluation of patients with Parkinson's disease (PD), most neurologists only see their patients during a limited period of their fluctuating 24-hour-a-day lives. This study aimed to assess the short-term outcome of STN stimulation for patients with advanced PD evaluated in a 24-hour monitoring unit for movement disorder (MUMD) using a prospective protocol. Methods : Forty-two patients with advanced PD consecutively treated with bilateral STN stimulation using multi-channel microelectrode recording were included in this study. All patients were evaluated using a 24-hour MUMD with a video recording/editing system and were evaluated with a prospective protocol of the Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Staging, Schwab and England Activities of Daily Living, levodopa equivalent daily dose (LEDD), Short Form-36 Health Survey, and neuropsychological tests. Magnetic resonance (MR) images of the brain were performed prior to and six months after surgery. Results : All patients were evaluated at three and six months after surgery. There was a rapid and significant improvement of the motor symptoms, especially in tremor and rigidity, after STN stimulation with low morbidity. Dyskinesia was markedly decreased with much lowered LEDD values by 50% after STN stimulation. 1.5T MR images were safely taken according to the manufacturer's guidelines at six months after surgery without any adverse effects in 41 patients treated with STN stimulations. Conclusion : Evaluations in a 24-hour monitoring unit could reduce the dose of medication efficiently to an optimal level with patients' comfort and improve the clinical symptoms in harmony with STN stimulation.

A Comparative Study on High School Students' Mathematical Modeling Cognitive Features

  • Li, Mingzhen;Hu, Yuting;Yu, Ping;Cai, Zhong
    • Research in Mathematical Education
    • /
    • v.16 no.2
    • /
    • pp.137-154
    • /
    • 2012
  • Comparative studies on mathematical modeling cognition feature were carried out between 15 excellent high school third-grade science students (excellent students for short) and 15 normal ones (normal students for short) in China by utilizing protocol analysis and expert-novice comparison methods and our conclusions have been drawn as below. 1. In the style, span and method of mathematical modeling problem representation, both excellent and normal students adopted symbolic and methodological representation style. However, excellent students use mechanical representation style more often. Excellent students tend to utilize multiple-representation while normal students tend to utilize simplicity representation. Excellent students incline to make use of circular representation while normal students incline to make use of one-way representation. 2. In mathematical modeling strategy use, excellent students tend to tend to use equilibrium assumption strategy while normal students tend to use accurate assumption strategy. Excellent students tend to use sample analog construction strategy while normal students tend to use real-time generation construction strategy. Excellent students tend to use immediate self-monitoring strategy while normal students tend to use review-monitoring strategy. Excellent students tend to use theoretical deduction and intuitive judgment testing strategy while normal students tend to use data testing strategy. Excellent students tend to use assumption adjustment and modeling adjustment strategy while normal students tend to use model solving adjustment strategy. 3. In the thinking, result and efficiency of mathematical modeling, excellent students give brief oral presentations of mathematical modeling, express themselves more logically, analyze problems deeply and thoroughly, have multiple, quick and flexible thinking and the utilization of mathematical modeling method is shown by inspiring inquiry, more correct results and high thinking efficiency while normal students give complicated protocol material, express themselves illogically, analyze problems superficially and obscurely, have simple, slow and rigid thinking and the utilization of mathematical modeling method is shown by blind inquiry, more fixed and inaccurate thinking and low thinking efficiency.

A Study for Protocol for Heterogeneous Interface in Sensor Networks within Water Restore Facilities (수질복원시설물 내 센서 네트워크 이기종간 인터페이스용 프로토콜에 관한 연구)

  • Kim, Chan;Shin, Jaekwon;Cha, Jaesang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.255-260
    • /
    • 2012
  • Currently, the management system of wastewater treatment facility has magnified due to the stringent regulations for the protection of the environment. However, wastewater treatment system is insufficient in wastewater quality monitoring technology in specialized. Above all it aim one-to-one data transmission instead of one-to-n data transmission through sensor and network. And then, it lack compatibility toward communication system between different. Mainly it has observed detecting system of manual system. In this paper, we studied protocol technology about efficient data transmission between sensor and integration interface of water quality detecting interface for automated sensor network integration interface in water restoration facility. Therefore, we proved the possibility of efficient data transmission from communication system of different type through monitoring implementation of sensor network integration interface.

A Study on Implementation of NMEA 2000 based Integrated Gateway using FPGA (FPGA를 이용한 NMEA 2000 기반 통합게이트웨이 구현에 관한 연구)

  • Park, Dong-Hyun;Hong, Ji-Tae;Kim, Kyung-Yup;Kim, Jong-Hyu;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.278-287
    • /
    • 2011
  • NMEA 2000 protocol known as IEC 61162-3 of Multi-talker, Multi-listener and Plug and Play network communication has been adopted as standard network for SOLAS(Safety of Life at Sea) ship by IMO. This paper focuses on the implementation of FPGA and MicroBlaze for NMEA 2000 based gateway, which is able to convert NMEA 2000 protocol into various types of network protocol such as Ethernet, UART and USB using Vertex4-based ML401 board. Each communication module and the stack of NMEA 2000 are mounted on FPGA. To be able to receive each communication data, ML401 board is configured to handle required communication speed. PC based NMEA 2000 monitoring program is developed to verify that data on different networks are correctly converted each other in real time.

A Implementation on Interface Module and Communication Protocol for Control Monitoring of the AtoN AIS (AtoN AIS 제어감시용 인터페이스 모듈과 통신프로토콜 구현)

  • Cha, Yeong-Mun;Jeong, Yeong-Cheol;Choi, Jo-Cheon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6B
    • /
    • pp.683-688
    • /
    • 2011
  • Current is change to concept that management traffic of ship os magnified gradually to near shore waters from harbor. Therefore, introducing the technology of AIS in the ground station, lighthouse, bouy, sea facilities etc.. that is support equipment for safety sailing of ship and safety security of harbor and ship administration. The operation and maintenance of AIS for aids to navigation are required to efficient method. With this actuality, sea advanced nation of EU, USA, Japan that has been apply for developing AtoN AIS equipment that is connected equipment of technology standard in IALA. Because of it is expected to depend equipment in income, that is required to domestic technology of the AtoN AIS. This paper is targeted to development that is suitable automation AtoN AIS equipment in environmental peculiarity for constructor AtoN operating administration center. It has been realization send protocol for information interchange.