• 제목/요약/키워드: Protective relaying

검색결과 110건 처리시간 0.03초

디지털 보호 계전기 전용 제어 칩 설계 (Design of digital relay controller on a single chip)

  • 서종완;정호성;권기백;서희석;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.215-217
    • /
    • 2000
  • Protective relay play a crucial role in the proper operation of a power system, and the reliable transfer of electrical power. This paper deals with the design and implementation of a digital protective relay on a single chip. Implementation on the FPGA(Field Programmable Gate Array) of the chip of digital protective relay. This protective relaying chip monitors the frequency and the voltage and current of the power system. And report the voltage, the current. the frequency, active power and reactive power.

  • PDF

보호계전기를 이용한 전기품질 감시 기법 연구 (Using Protective Relaying for Power Quality Monitoring)

  • 배영준;임성일;최인선;이승재;김정한;김병진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.

  • PDF

비접지 DC 급전계통에서 전류형 지락보호계전기의 사용 (New Ground Fault Protective Relay in DC Traction Power System)

  • 정상기;백남욱;김연수;이성혁;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1297-1302
    • /
    • 2004
  • In DC power distribution system for urban rail transits potential relay, 64P, is used to detect the ground faults. The problem with this 64P is that though it detects the ground fault it cannot identify the faulted region. Therefore the faulted region cannot be isolated properly. It could results in power loss of the trains on the healthy regions and the safety of the passengers in the trains could be affected adversely. A new ground fault protective relaying scheme that can identify the faulted region is presented in this paper. The new concept uses the current differential scheme and the permissive scheme to identify the faulted region correctly. A device with similar characteristic to the arrestor is adapted to use the current relay for the ground fault detection. The role of the device is to block the ground leakage current in normal operating condition and enable the ground fault current to flow in ground fault condition. The algorithm of the new relay and the effect of the newly adapted device in the new relaying scheme are discussed.

  • PDF

Fuzzy Decision-Making을 이용한 지능형 변압기 보호 계전 알고리즘 (An Intelligent Power Transformer Protective Relaying Algorithm Based on Furzy Decision-Making)

  • 이승재;강상희;최면송;김상태;강대훈;김기화;김일동;장병태;임성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.891-893
    • /
    • 1997
  • In this paper an intelligent power transformer protective relaying algorithm based on Fuzzy Decision-Making is presented. The introduced protection algorithm contains several internal fuzzy rule-bases including bpa(Basic Probability Assignment: m) which are subject to off-line pre-installation by the analysis of the transformer transient characteristics for detecting the internal fault. Dempster-Shafer's rule of combination is used for the inference method with rules to decide the situation of a transformer, The proposed algorithm immunes to the saturation of transformer, inrush conditions, over excitation, and external fault. The included results of testing show practically sufficient sensitivity and selectivity of the proposed algorithm.

  • PDF

쇄교자속비를 이용한 변압기 보호 알고리즘 (A Transformer protective Relaying Algorithm Based on Increment of Flux Linkages)

  • 강용철;이병은;김은숙;원성호;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.53-55
    • /
    • 2003
  • This paper propose a transformer protective relaying algorithm based on the increment of flux linkages (RIFL) of the Primary and secondary windings. The RIFL is equal to the turn ratio for all operating conditions except an internal faults. For a single-phase transformer and three-phase Y-Y transformer, the increments of flux linkages are calculated and their ratios are compared with the turn ratio. For a three-phase Y-$\triangle$ transformer, the difference of the increments of flux linkages are calculated to use the line currents instead of the delta winding currents, which are practically unavailable. Their ratios are compared with the turn ratio. The results of various tests show that the algorithm successfully discriminates internal faults from normal operation conditions such as magnetic inrush and overexcitation. The algorithm can not only detect internal winding faults, but reduce the relay's operating time.

  • PDF

쇄교자속비를 이용한 3권선 변압기 보호 알고리즘 (A Three-Winding Transformer Protective Relaying Algorithm Based on Flux Linkages Ratio)

  • 강용철;이병은;김은숙;원성호;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.341-344
    • /
    • 2003
  • This paper proposes a tree-winding transformer protective relaying algorithm based on the ratio of increment of flux linkages (RIFL). The RIFL of the two windings is equal to the turns ratio for all operating conditions except an internal faults. For a single-phase transformer and three-phase transformer containing the wye-connected windings, the increments of flux linkages are calculated. for a three-phase transformer containing the delta-connected windings, the difference of the increments of flux linkages between the two phases are calculated using the line currents, because the winding currents are practically unavailable. Their ratios are compared with the turns ratio. The results of various tests show that the algorithm successfully discriminates internal faults from normal operation conditions such as magnetic inrush, overexcitation and external faults. The algorithm can not only detect internal winding faults, but reduce the operating time of a relay.

  • PDF

DSP를 이용한 변압기용 디지털 보호계전기 설계에 관한 연구 (A Study on Design of Digital Protective Relay for Transformer Using a DSP)

  • 서희석;권기백
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.39-46
    • /
    • 2003
  • 본 논문에서는 디지털화 경향에 맞추어 변압기를 보호함과 아울러 감시 및 계측 등의 기능을 갖춘 변압기용 디지털 보호계전기를 개발하기 위한 하드웨어 및 실시간 처리가 가능한 소프트웨어의 구현 방법 등을 제시하였다. 특히 보호계전기의 모든 알고리즘 및 보조 프로그램들이 단일 프로세서에 의해 실시간으로 수행될 수 있도록 DSP의 DMA 제어기를 이용하여 아날로그 입력 데이터를 처리하였다. 아울러 비휘발성 메모리 (EEPROM, flash memory)에 보호계전 알고리즘의 수행에 필요한 각종 설정치, 이벤트 및 고장데이터를 저장하고 UART를 이용하여 데이터를 분석할 수 있도록 하였다. 그리고 시험용 변압기용 디지털 보호계전기를 제작하여 일본 NF 사의 보호계전기 시험기를 이용하여 변압기 보호기능 및 동작특성을 시험하여 그 성능을 입증하였다.

전력계통의 패턴인식형 거리계전기법에 관한 연구 (A Study on the Pattern Recognition based Distance Protective Relaying Scheme in Power System)

  • 이복구;윤석무;박철원;신명철
    • 한국지능시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.9-20
    • /
    • 1998
  • 본 논문에서는 패턴인식 형태로 구성된 거리계전시스템에 신경회로망을 적용한 새로운 형태의거리계전기법이 제시되었다. 제안된 거리계전기법은 패턴인식 단계인 두개의 블록으로 구성되었다. 첫 단계에서는 과도신호의 특징 파라미터인 기본파성분을 효율적으로 추출하기 위해 신경회로망을 이용한 필터링 방법이 적용되었으며, 두번째 단계에서는 첫단계에서 추출된 기본파성분을 입력으로 고장형태를 신속하고 정확하게 판별 분류 될 수 있도록 신경회로망을 이용한 고장패턴 추정기가 개발적용되었으며, 이울러 고장판별에 따라 고장점을 효율적으로 추정될 수 있도록 하였다. 적용 시스템의 각 단계는 함수 근사화, 보간성능 및 패턴분류 등의 능력이 뛰어난 다층 퍼셉트론의 역전파 학습 알고리즘이 적용되었다. 제신된 기법의 성능을 입증하기 위하여 EMTP 시뮬레이션을 하여 얻은 다양한 과도 고장파형의 계전시호를 활용하여 시험하였으며, 그결과 제시된 기법은 학습되지 않은 임의의 패턴에 대하여 적응성을 가지고 효율적으로 고장점이 추정될 수 있었으며, 고장발생후 3샘플 이내에서 고장형태가 신속하고도 정확하게 판별되었다.

  • PDF

분산전원 계통 연계 전용선로에 설치된 보호 계전기의 정정에 관한 연구 (A Study on Correction of the Protective Relay Equipped in the Dedicated Line Used for Connecting Distributed Generators to Power Network)

  • 정종찬;장성일;최돈만;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.141-144
    • /
    • 2002
  • This paper describes the correction of the protective relay equipped in the dedicated line used for connecting distributed generators (DG) to power grid. The fault current measured in a relaying point might be changed according to the fault conditions. Generally, the fault current of the line to line fault or the line to ground fault at the dedicated line is much higher than the protective set value due to the large fault level. However. when the high impedance fault is occurred in the dedicated line, we may not detect it because its fault level can be lower than the generating capacity of DG. And, the protective relay with conventional set value may generate a trip signal for insertion of DG due to the large transient characteristics of generators. Through the various simulations such as the fault in the dedicated line and the insertion of DG, we show that it would be necessary to modify the protective relay set value for detecting the high impedance fault occurred in the dedicated line and for preventing the mis-operation of protective relay caused by the insertion of DG.

  • PDF

DFT 기반의 개선된 페이저 연산 기법을 적용한 거리계전 알고리즘 (Distance Relaying Algorithm Using a DFT-based Modified Phasor Estimation Method)

  • 이동규;강상희
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1360-1365
    • /
    • 2010
  • In this paper, we propose a distance relaying algorithm using a Discrete Fourier Transform (DFT)-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Most distance relays are based on estimating phasors of the voltage and current signals. A DFT is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. For this reason, distance relays have a tendency to over-reach or under-reach in the presence of DC offset components in a fault current. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. The error due to DC offsets in a DFT is calculated and eliminated using the outputs of an even-sample-set DFT and an odd-sample-set DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated for a-phase to ground faults on a 345 kV, 50 km, simple overhead transmission line. The Electromagnetic Transient Program (EMTP) is used to generate fault signals. The evaluation results indicate that adopting the proposed algorithm in distance relays can effectively suppress the adverse influence of DC offsets.