• Title/Summary/Keyword: Protective device

Search Result 271, Processing Time 0.032 seconds

Simulation Method on the Protection Effects of Voltage-Limiting Type SPDs Associated with the Protective Distance (보호거리에 따른 전압제한형 SPD의 보호효과에 대한 시뮬레이션기법)

  • Lee, Bok-Hee;Kim, You-Ha;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a method of simulating the protection effects of surge protective devices(SPDs) depending on the protective distance and types of input impedance of load to be protected. In order to analyze the protective performances of voltage-limiting type SPDs associated with the reflection and oscillation phenomena, the terminal voltage across load being protected and the residual voltage of SPDs were simulated by using EMTP model as functions of the protective distance and types of input impedance of loads. As a consequence, SPDs should be installed by taking into account the protective distance and input impedance of loads to achieve reliable protection of electrical and electronic equipment from lightning and switching surges. It is expected that the simulation method proposed in this paper could be practically used in design for installing SPDs in low-voltage distribution systems.

A Development of Software about Short-circuit Calculation and Protective-coordination (고장계산 및 보호협조 판정 소프트웨어 개발)

  • Park, S.C.;Choe, J.H.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.159-162
    • /
    • 2002
  • A software, called touch-one, is developed about the determination of short-circuit values and protective co-ordination in power system. The used solution algorithm reviewed intensively, and the protective co-ordination determination technique presented by using the circuit-breaker's current-limitation characteristic. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. With this software, we can construct a electric-power system which is reliable and economic according to user's purpose.

  • PDF

A Study on Hand Speed Constant to Calculate Safe Distance of Press Protective Device (프레스 방호장치 안전거리 산정을 위한 손속도상수)

  • Lee, Keun-Oh;Kim, Jong-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.40-46
    • /
    • 2010
  • To protect press operator from the after-reach hazard, current Ministry of Labor Notification(MOLN) requires the use of a formula for calculating the safe distance away from the point of operation for locating press protective devices, Two Hand Control Devices(THCD) and Active Opto-Electronic Protective Devices(AOPD), on a power press. This formula is based on a same hand speed constant of 160cm/s. While EN standards use different hand speed constant for THCD and AOPD respectively. The objective of this study is to compare two guidelines on the hand speed constant published by MOLN and EN 692, also to propose a proper hand speed constant and validate it experimentally. As a experimental result, it could be known that hand speed constant of Ministry of Labor Notification should be improved as that of EN standards.

Stress-Strain of Geomembranes In Landfill Under Punctiform Loads (폐기물매립장 차수재의 꿰뚫림 하중에 의한 응력-변형)

  • 이광열;정진교
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.06a
    • /
    • pp.55-65
    • /
    • 2001
  • Geotextiles are usually constructed as a protective layer of geomembranes in liner systems for the solid waste landfill. A protective layer and geomembrane are susceptible to mechanical damage by coarse grains in the overlying drainage layer. In this study, therefore, the strain behavior of geotextile protective layers was investigated using three different types of devices for developing punctiform loads. The results of the study showed that the rates of strain was different depend upon device types for functiform loads. Also, It was found that the increases in strain was approximately linear in range 20 to 6$0^{\circ}C$ , and pp-filament non-woven geotextiles yielded a better efficiency than pp-staple fiber non-woven geotextiles.

  • PDF

Parametric Evaluation Method of Protectability in a Distribution System (파라메터 관점에서의 배전계통 보호도 평가방법)

  • Cho, P.S.;Hyun, S.H.;Lim, S.I.;Lee, S.J.;Lee, D.S.;Waldemar, Waldemar
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.241-243
    • /
    • 2002
  • Recently, great efforts are concentrated on the autonomous, adaptive protection schemes with advanced artificial intelligence and digital technology. It is highly required for a next generation protective system not only to detect and to clear a fault, but also to fit itself to the changing environment. In this paper it is suggested an evaluation method for the protection ability of a protective system in a distributed system. The suggested method is of bottom-up scheme, in other words, protection ability is estimated from the lowest level of parameters in each protective devices to the highest level of the whole protective system. This feature makes it possible to evaluate the protection ability either for the protective device(or a system), or for a protected system. And, in addition, it is enabled that the protectability concept can be applied in the design stage of a protective system for a distribution network. The proposed method is applied to a simple distributed network to show its effectiveness.

  • PDF

The Effect of Protective Socks with Functional Insoles on Plantar Foot Pressure in Diabetes Patients

  • Kim, Hyun Soo;Jung, Do Young
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.6
    • /
    • pp.224-228
    • /
    • 2018
  • Purpose: The most common cause of plantar ulceration is an excessive plantar pressure in patients with peripheral neuropathy. Foot orthosis and therapeutic footwear have been used to decrease the plantar pressure and prevent the plantar ulceration in in diabetes patients. We investigated whether protective sock with functional insoles reduce plantar pressure while walking in 17 diabetes patients. Methods: An in-shoe measurement device was used to measure the peak plantar pressure while walking. Peak plantar pressure data were collected while walking under two conditions: 1) wearing diabetic sock and 2) wearing the protective sock with functional insoles. Each subject walked 3 times in 10-m corridor under three conditions, and data were collected in 3 steps in the middle of corridor with in right and left feet, respectively. Pared t-test was used to compare the peak plantar pressures in three plantar areas under these two conditions. Results: The protective sock with functional insoles significantly reduced the peak plantar pressure on the lateral rearfoot, but significantly increased the peak plantar pressure on the middle forefoot, and medial midfoot (p<0.05). However, there were not significant in medial and lateral forefoot, lateral midfoot, and medial rearfoot between diabetic sock and the protective sock conditions (p>0.05). Conclusion: The protective sock with functional insoles reduced plantar pressures in the rearfoot and supported the medial longitudinal arch. However, it is necessary to change the position of metatarsal pad in the insole design of forefoot area to prevent diabetic foot ulceration.

Development and/or Characteristics Evaluation of High Performance SPD(Surge Protective Device) (고성능 서지보호 시스템 개발 및 성능 평가)

  • Kim, Jae-Hoon;Kim, Ju-Han;Han, Sang-Ok;Kim, Sun-Ho;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.328-333
    • /
    • 2009
  • In this paper, we have developed high performance SPD(surge protective device) and evaluated the characteristics in comparison with typical SPD used in the inside and outside of the country. The new SPD was composed of MOV(metal oxide varistor), GDT(gas discharge tube) and impedance such as resistors, capacitors or varistors. To estimate operating the characteristic of the SPD which was developed, it was measured surge voltage caused by fault current or surge according to IEC 61000-4-5. As a result it was found that the power supply was cut off by high performance SPD when caused a short-circuit. In addition we could know that it could prevent ELB(earth leakage breaker)'s malfunction caused by surge.