• 제목/요약/키워드: Protective device

검색결과 271건 처리시간 0.03초

의료기기 재처리 세척 직원의 개인보호구 착용 이행의 영향요인 (Factors Influencing Compliance on the Use of Personal Protective Equipment during Cleaning of Medical Device Reprocessing Staffs)

  • 박현희;홍정화;정계선;이광옥
    • 근관절건강학회지
    • /
    • 제31권1호
    • /
    • pp.42-52
    • /
    • 2024
  • Purpose: This study aimed to identify the factors affecting compliance with personal protective equipment (PPE) use among medical device reprocessing staff. Methods: This descriptive cross-sectional study included 163 cleaning staff members from ten general hospitals in Seoul and Gyeonggi. Data were collected using self-report questionnaires administered between July and September 2023. Analysis included t-tests, ANOVA, Pearson's correlation coefficient, Bonferroni correction, and multiple regression, conducted using SAS ver.9.4. Results: Statistically significant differences in compliance with PPE were found based on department and exposure to contamination within six months (t=-2.82, p=.007). Attitudes toward PPE (r=.22, p=.006) and awareness of the safety climate (r=.22, p=.006) showed a statistically significant positive correlation with PPE compliance. Factors influencing use of personal protective equipment by cleaning staff during medical device reprocessing were department, compliance with PPE, and awareness of the safety climate. The explanatory power of these factors was 58.0%. Conclusion: Improving PPE compliance and creating a safe cleaning environment entails fostering a supportive safety climate. Additionally, regular training that takes into consideration the characteristics of the cleaning staff, alongside continuous monitoring, is required.

선박 신호회로용 서지방호장치의 개발 (Development of a Surge Protective Device for Signal Lines on Shipboard)

  • 서황동;송재용;한주섭;김윤식;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1161-1165
    • /
    • 2005
  • Due to the miniaturization of electrical components and assembles on signal circuits, transient overvoltages caused by switching operation or lightning surges have become more interesting concern to the field of electrical engineering. In this paper, the development of surge protective devices(SPDs) that can protect sensitive signal device on shipboard from overvoltages are described. Two kinds of SPDs are designed and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}s$ 2.1kA according to the IEC 61000-4-5 standard. From the simulation and experimental results, it is confirmed that the proposed SPDs have an enough protection performance with a low insertion loss and a low clamping voltage.

  • PDF

22.9KV 배전설게 보호협조을 위한 전문가 시스템 (An Expert System for Protection Coordiantion in 22.9KV Distribution System Design)

  • 김호용;고윤석;손수국;남기영
    • 대한전기학회논문지
    • /
    • 제39권2호
    • /
    • pp.119-132
    • /
    • 1990
  • To design protection coordination for an electric power distribution system, an expert system is developed, using both the veteran expert's heuristics and the guide book for the distribution facility operation considering feeder configuration, service route, load characteristics fault current and load current. The expert system developed in this papaer determines the type of protective device(clearing current and sequence). The location and rating change of protective device in the old feeder is realized by using old database. Current(T-C) curves of various kinds of protective devices are stored in Knowledge Base (KB). The expert system is developed on a 32 bit personal computer using PROLOG, AutoCAD,dBASEIIIPLUS and FORTRAN. To compute the fault current and loadflow, FORTRAN is used.

  • PDF

파라메터 관점의 보호능력 평가지표를 이용한 보호기기의 위치 선정 (Optimal Location of a Protective Device by using Parametric Protection Ability Index)

  • 신재항;임성일;현승호;이승재;하복남;설일호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.366-368
    • /
    • 2003
  • In this paper, a parametric evaluation method of protection ability is proposed. The adequacy of every parameter is evaluated for the setting rules. Then the results are combined to give protection level of a whole protective system. The setting rules are categorized into three groups for hierarchical calculation. The proposed scheme is applied to a location problem of a new protective device to show its effectiveness.

  • PDF

주택용 분전반에 설치되는 서지보호기의 열적 안전성 시험 및 분석 (A thermal stability testing and analysis for a surge protector installed in residential distribution board)

  • 김주철;박장범;기채옥
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.339-341
    • /
    • 2009
  • 개별세대 내 정보통신기기 및 홈네트워크 장비증가로 인하여 서지보호장치(SPD : Surge Protective Device)가 설치되고 있고 산업규격개정 및 등전위 접지시스템 강화에 따라 서지보호기 사용량은 점진적으로 증가하고 있다. 주택용 분전반에 설치되는 서지보호기의 부품은 전압제한형 소자인 $Z_nO$배리스터가 사용되고 있으나 일시적 과전압특성 (Temporary Overvoltage Characteristic) 위험에 노출되어있다. 본 논문은 일반주택에 사용되는 서지보호기의 열적 안전성 (Thermal Stability) 특성시험을 통하여 제품을 분석하였고 이를 토대로 개선안을 제시하였다. 분석결과 누설전류를 차단하기위한 가스 방전관(GDT) 사용 및 열폭주(Thermal Runaway) 현상을 막기 위한 안전장치가 2종 이상 필요하였다.

  • PDF

보호거리와 부하 유형에 따른 SPD의 보호효과에 대한 실험적 고찰 (Experimental Examinations on Protective Effects of SPDs Associated with the Protective Distance and Type of Load)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.81-88
    • /
    • 2012
  • Surge protective devices(SPDs) are widely used as a most effective means protecting the electrical and electronic equipment against overvoltages such as lightning and switching surges. When installing SPDs, it is essential that the voltage protection level provided by SPDs should be lower than the withstand voltage of the equipment being protected. But even the proper selection of SPDs are achieved, the voltage at the equipment terminal may be higher than the residual voltage of SPD due to the reflection and oscillation phenomena. This paper was focused on the investigations of the conditions for which the equipment is protected by an SPD taking into account the influences of the protective distance and type of load. The protective effects of SPD with voltage-limiting component were analyzed as functions of types of load and protective distance between the SPD and load. As a result, in the cases of long protective distances, capacitive loads and loads with high resistance, the voltage at the load terminal was significantly higher than the residual voltage of SPD. It was found that the proper installation of SPDs should be carried out by taking into account the protective distance and type of load to achieve reliable protection of electronic equipments against surges.

인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선 (Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module)

  • 김주철;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

배전변전소에 대용량변압기로 교체 적용시 보호협조를 위한 초전도 전류제한기의 임피던스 분석 (Analysis on SFCL's Impedance for Protective Coordination in Large Transformer installed in Distribution Substation)

  • 김진석;김명후;류일경;문종필;임성훈;김재철;안재민
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1479-1484
    • /
    • 2009
  • The introduction of the large transformer due to the large power demand has increased the fault current in power distribution system. The increased fault current can exceed the cut-off ratings of the circuit breaker. As the methods to solve this problem, the superconducting fault current limiter(SFCL) has been notified. However, the limited fault current by SFCL affects the operational characteristics of the protective device such as overcurrent relay. Therefore, the selection of the proper impedance for the SFCL is required to keep overcurrent relay's protective coordination with the SFCL when a large transformer is introduced into the distribution system. In this paper, the SFCL's impedance for protective coordination was investigates in that a large transformer is introduced.

전원용서지보호장치(Surge protective devices connected to low-voltage power systems)의 열안전성시험(Thermal stability test)의 방법 및 판단에 대한 고찰 (The study of method and verification that Surge protective devices connected to low-voltage power systems of the thermal stability test)

  • 최길;박신우;임병배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1213-1214
    • /
    • 2015
  • 서지보호장치(Surge Protective Device)가 국내에 본격적으로 설치된 것은 산업화의 발전으로 인해 현장 전력시스템의 복잡성과 다양성 및 급격히 변화하고 있는 우리나의 기후변화 때문일 것이다. 전원계통의 전원용서지보호장치(Poser Systems Surge Protective Devices) 및 통신계통의 통신용서지보호장치(Telecommunication Surge Protective Devices)의 설치는 해마다 증가하고 있다. 이에 따른 제품개발도 급속도로 이루어지고 있으며, 과거 몇년 전만해도 서지보호장치에 대한 표준과 시험설비의 이해와 부족으로 인해 표준에 의한 제품검증이 어려웠으나 2013년 제정된 KS 표준(KS C IEC 61643-11)으로 상당수 제조자가 관련인증을 취득하고 있다. 이 논문에서는 KS표준에서 정의하고 있는 열안전성시험에 대한 방법과 결과판정 및 새로운 기준을 제시하고자 한다.

  • PDF

Protective System from Medical Needle-sticks. Part II: Evaluation of Woven Structures and Bifid Needles

  • Seyam, Abdelfattah M.;Turner, LaDawnya C.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • 제4권3호
    • /
    • pp.129-134
    • /
    • 2003
  • We have shown in Part I [1] of this study that medical needle-stick injuries are causing serious health problems to healthcare personnel and other professionals that require the attention of healthcare and textile researchers to develop new protective systems. Responding to such need, a needle force measurement device that is capable of measuring dynamic forces experienced by medical needles during needle penetration through protective articles was developed and described in part I. This paper reports the results of evaluation of protective woven fabrics from high performance fibers and standard and bifid medical needles using the force measurement system. The woven fabrics varied in cover factor, number of layers, and orientation angle. Standard and bifid needles with different gap widths were used to evaluate the resistance of the fabric to needle penetration.