• 제목/요약/키워드: Protective Relay

검색결과 237건 처리시간 0.027초

A Novel Digital Over Current Relay with Variable Time-Current Characteristics for Protective Coordination

  • Park, M. S.;P. S. Cho;Lee, S. J.;S. H. Hyun;Kim, K. H.
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.83-88
    • /
    • 2002
  • An over current relay(OCR), one of the most frequently used protective devices, has time-current characteristics (TCC) to control its trip time according to the current level. It is because an appropriate operating time interval is necessary for coordination with other protective devices. A set of TCC curves of an OCR is, in general, given by the supplier from which a curve is selected by the operator. Therefore, in many cases, it is impossible to consider the operation condition of the given power system exactly. A novel concept of an OCR is suggested in this paper. The proposed OCR has an internal correction module so that it may produce the most adequate TCC curve according to the given protective information for coordination with other devices. With the generated TCC curve, a variety of operation and coordination conditions can be taken into consideration in an effective manner. The suggested OCR is applied to a simple test power system to show very promising results from a coordination point of view.

네트워크 기반 보호계전기 시뮬레이터용 과전류 계전 알고리즘 모듈 구현 (Development of an Over-Current Relaying Algorithm Module for a Network-Based Protective Relay Simulator)

  • 박건호;김동희;고자영;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.741-742
    • /
    • 2011
  • In this paper, an over-current relay algorithm module for a network-based protective relay simulator is proposed. The proposed protective simulator is based on the client-sever paradigm. The module composed of a server and user interface provides a network-based simulation environment.

  • PDF

보호 계전기 동특성 테스트를 위한 임피던스 궤적 모델 개발 (Development of Impedance Locus Model for Protective Relay Dynamic Test)

  • 김수남;이재규;이명수;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.451-459
    • /
    • 2002
  • This paper presents a method for modelling of the impedance locus in order to test the protective relay with dynamic. This paper has the two parts, the first part is the configuration of impedance locus with voltage magnitude, total impedance magnitude and angle. And the second part is the control of the locus speed with deviation of two frequencies. The proposed method is applied to two machine equivalent system with PSCAD/EMTDC to show its effectiveness.

UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템 (Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;조종만;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

DSP의 DMA 제어기를 이용한 변압기용 디지털 보호계전기의 성능향상 (Efficiency Improvement of Digital Protective Relay for Power Transformer Using DMA Controller of DSP)

  • 권기백;서희석;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.647-654
    • /
    • 2003
  • As electrical power system has become complicated and enlarged to cope with the increasing electric demand, it has to be expected that higher speed, higher reliability, higher function and higher arithmetic ability in protective relay should be realized. Therefore, in this papers, by hardware design and implementation used DMA controller that transfer blocks of data to any location in the memory map without interfering with CPU operation, CPU utilization is increased effectively, as a result it made possible to implement multi-function digital protective relay which has high trust and high function of protection as well as control and metering for power transformers using single processor(DSP).

컴포넌트 오브젝트 모델을 응용한 계전 알고리즘 구현방법의 개선에 관한 연구 (A Study on the Improvement of the Method for Implementing Protection Algorithm by using Component Object Model(COM))

  • 박인권;윤남선;안복신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1210-1212
    • /
    • 1998
  • The complexity of newly developed protection algorithm and higher performance requested by the user makes the software embedded in the protective relay much harder to develop and maintain. The versatility of 32bit microprocessor and the availability of cheaper memory semiconductors introduced the fertile developing background for the protective relay developers. The use of component object model(COM) in the software developing process enables the developer to write much complex code in the easy and safe way and to maintain the code easily, too. And the aid of the COM library, the distributed computing environment will be expected to appear by the use of the COM programming model in the protective relay firmware program.

  • PDF

지하철 직류보호계전시스템의 동작특성에 관한 연구 (A Study on Operational Characteristics of DC protective relay systems on the Subway)

  • 정현기;정종진;안태풍
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.451-465
    • /
    • 2008
  • 지하철에서는 직류보호계전시스템으로 정한시과전류계전기(76i)와 저전압계전기(Mid-point Relay, 80A)를 사용하여 직류급전계통을 보호하고 있었으나, 최근에는 보호방식으로 고장선택계전기(50F)를 주로 적용하고 있다. 본 연구에서는 현재 서울메트로 3 4호선에 적용하여 사용하고 있는 76i/80A와 50F 각각의 직류급전계통 보호방식을 비교하기 위해 단락고장계산식을 이용하여 분석하였으며 PSCAD/EMTDC 과도프로그램을 통한 시뮬레이션으로 연구하였다. 분석한 결과 80A는 고장저항의 크기에 따라 동작여부가 달라지고, 50F의 경우 고장저항의 크기나 선로의 길이가 변하더라도 일정시간이 지나면 설정값에 따라 동작함을 확인하였다. 이에 향후 직류보호계전시스템의 운영에 있어 합리적인 적용을 제시하고자 한다.

  • PDF

배전변전소에 대용량변압기로 교체 적용시 보호협조를 위한 초전도 전류제한기의 임피던스 분석 (Analysis on SFCL's Impedance for Protective Coordination in Large Transformer installed in Distribution Substation)

  • 김진석;김명후;류일경;문종필;임성훈;김재철;안재민
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1479-1484
    • /
    • 2009
  • The introduction of the large transformer due to the large power demand has increased the fault current in power distribution system. The increased fault current can exceed the cut-off ratings of the circuit breaker. As the methods to solve this problem, the superconducting fault current limiter(SFCL) has been notified. However, the limited fault current by SFCL affects the operational characteristics of the protective device such as overcurrent relay. Therefore, the selection of the proper impedance for the SFCL is required to keep overcurrent relay's protective coordination with the SFCL when a large transformer is introduced into the distribution system. In this paper, the SFCL's impedance for protective coordination was investigates in that a large transformer is introduced.

광전자식 과전류 보호계전기의 구현에 관한 연구 (Implementation of Optoelectric Over Current Relay)

  • 박병석;오면택;이화준;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1846-1849
    • /
    • 1998
  • An optical magnetic filed sensor, YIG (Yittrium Iron Garnet), response rapidly, to the power-line currents to be measured. In response to Faraday effect, it shows wide-and-linear measurable range. This paper reports the development and implementation of an OOCR (Optoelectric OverCurrent Relay) using this sensor. This relay is free from environmental electro-magnetic noises and has excellent insulation characteristics inherently. By using this OOCR, we can reduce insulation cost of protective relaying systems and its maintenance cost, and can achieve high reliability of the system.

  • PDF