• 제목/요약/키워드: Protective Material

검색결과 460건 처리시간 0.026초

Electromagnetic Pulse Shielding Effectiveness and Construction Availability of Cast-In-Place Structures Using Corrugated Metal-Plates

  • Kim, Suk Bong;Yoon, Sangho;Min, Gyung Chan;Ahn, Sungjin;Park, Young Jun
    • 한국건축시공학회지
    • /
    • 제13권1호
    • /
    • pp.84-89
    • /
    • 2013
  • This study aims to examine the effectiveness of electromagnetic pulse shielding in cast-in-place protective shelters using corrugated metal-plates, and then reviews their usability for the Republic of Korea Army. The Korea Corps of Engineering has evaluated corrugated metal-plates as a construction material for cast-in-place structures, which have to defend against mechanical impacts as well as electromagnetic pulses. Corrugated metal-plate is known as a superb mechanical protective material, so much so that it has been employed in ammunition magazines and artillery platforms in the armed forces. Moreover, as a metal, such as steel and copper, it is universally recognized as one of the most effective electromagnetic pulse shielding materials. In addition to effectively shielding from electromagnetic pulses and protecting against mechanical impacts, corrugated metal-plates should prove to be an appropriate construction material for the cast-in-place protective shelter in terms of construction availability and economic feasibility. The shielding effectiveness of the suggested structures is examined based on MIL-STD 188-125-1. A few frequency bands need an increase of 15~30dB in shielding effectiveness because of unbidden apertures caused by flaws associated with welding, assembling, and material deformation. However, allowing for the approximately 40dB of shielding provided by soil; the examined structure, which is buried underground, can offset its shortcomings sufficiently.

필라멘트 와인딩 복합재 압력용기의 충격저항성에 미치는 표면 고무 보호재료의 영향 (The Effect of Surface Protective Material on the Impact Resistance in Filament Wound Composite Pressure Vessel)

  • 강기원;김용수;이미애;최린
    • 한국안전학회지
    • /
    • 제20권4호
    • /
    • pp.14-19
    • /
    • 2005
  • One area in which composites have been used rather extensively is for fabricating pressure vessel. These structures can be readily manufactured by filament winding, which is, as far as composite fabrication techniques are concerned, a relatively inexpensive method for producing composite structures. Unfortunately, the higher strength material and fabrication costs are not the only disadvantages of fiber-reinforced polymer composites when they are compared to metals. Additionally, these materials tend to exhibit brittle behavior. This is of particular concern when they are subjected to a low-velocity impact during routine handling a significant amount of structural damage can be introduced into the composites. The goals of this paper are to understand the impact damage behavior and identify the effect of surface coating materials on impact resistance in filament wound composite pressure vessels. For these, a series of low velocity impact tests was performed on specimens cutting from the full scale pressure vessel by the instrumented impact testing machine. The specimens are classified into two types with and without surface protective material. The visualization for impact damage is made by metallurgical microscope. Based on the impact force history and damage, the resistance parameters were employed and its validity in identifying the damage resistance of pressure vessel was reviewed. As the results, the impact resistance of the filament wound composites and its dependency on the protective material were evaluated quantitatively.

Investigation of Sweet and Sour Corrosion of Mild Steel in Oilfield Environment by Polarization, Impedance, XRD and SEM Studies

  • Paul, Subir;Kundu, Bikramjit
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.249-256
    • /
    • 2018
  • Metallic structures in the oil and gas production undergo severe degradation due to sweet and sour corrosion caused by the presence of $CO_2$ and $H_2S$ in the fluid environment. The corrosion behavior of 304 austenitic stainless was investigated in the presence of varying concentrations of $CO_2$ or $H_2S$ and $CO_2+H_2S$ to understand the effect of the parameters either individually or in combination. Potentiodynamic polarization study revealed that a small amount of $CO_2$ aided in the formation of calcareous deposit of protective layer on passive film of 304 steel, while increase in $CO_2$ concentration ruptured the layer resulting in sweet corrosion. The presence of $S^{2-}$ damaged the passive and protective layer of the steel and higher levels increased the degradation rate. Electrochemical impedance studies revealed lower polarization resistance and impedance at higher concentration of $CO_2$ or $H_2S$, supporting the outcomes of polarization study. XRD analysis revealed different types of iron carbides and iron sulphides corresponding to sweet and sour corrosion as the corrosion products, respectively. SEM analysis revealed the presence of uniform, localized and sulphide cracking in sour corrosion and general corrosion with protective carbide layer amid for sweet corrosion.

산소 플라즈마 처리후의 이차전자방출계수(γ)를 이용한 MgO 보호막의 일함수(φW) 변화 (Work Function Changes on MgO Protective Layer after O2plasma Treatment from Ion-induced Secondary Electron Emission Coefficient)

  • 정재천;유세기;조재원
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.259-263
    • /
    • 2005
  • The changes in secondary electron emission coefficient(${\gamma}$) and work function($\Phi$$_{\omega}$) have been studied on the surface of MgO protective layer aster plasma(Ar. $O_2$) treatment using ${\gamma}$-focused ion beam (${\gamma}$-FIB) system. The values of ${\gamma}$ varied as follows: $O_2$-treated MgO > Ar-treated MgO > Non-treated MgO, and the work functions varied in the reverse order. The result indicates that both the physical etching and the chemical reaction of $O_2$-plasma removed the contaminating materials from the surface of MgO.

최적 증착 속도로 형성된 MgO를 갖는 인-라인 진공 실장된 플라즈마 디스플레이 패널의 방전 특성에 관한 연구 (A Study on Discharge Characteristics of the PDP Packaged with In-situ Vacuum Sealing with the MgO Protective Layer Deposited by Optimal Evaporation Rate)

  • 이조휘;조의식;권상직
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.916-922
    • /
    • 2008
  • AC PDP with MgO protective layer coated with the optimum evaporation rate of $5{\AA}/s$ can generate more enhanced efficiency through the vacuum in-line sealing process. However, the optimized process conditions still require the optimum driving scheme on the ramp-up and ramp-down slope of the reset waveform for enhancing the efficiency. In this paper, for the in-situ vacuum sealed PDP with the optimum evaporation rate of MgO protective layer, the address delay time was investigated with various slopes of ramp waveform during a reset ramp-up and ramp-down period. In this study, the minimum statistical delay time was obtained at the ramp-up rate of $6.0 V/{\mu}s$ and the ramp-down rate of $0.7 V/{\mu}s$ of the reset waveform.

저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구 (Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures)

  • 이준경;방영준;방창훈;권정숙
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2014
  • 보호복 섬유 및 재료의 개발을 통해 나아진 단열 성능을 제공함에도 불구하고 보호복의 화상 방지는 아직도 중요한 사항이다. 화염으로부터의 보호성능을 보장받기 위해서 보호복의 정확한 성능검증이 필요하며, 열보호 특성을 정확히 파악하기 위해 ISO 등은 시험방법을 표준화하여 제시하고 있다. 하지만 대부분의 경우, 높은 열유속 조건에 대해 보호복의 열보호 성능을 시험하는 것으로 되어 있어, 고열유속에 의한 시편의 파괴가 일어나기 쉽다. 그러므로 낮은 열유속 조건에서 보호복의 열보호 성능을 측정하는 방법이 필요하며, 본 연구에서는 낮은 열유속에 대한 열보호 성능을 측정할 수 있는 화상 및 통증유발시간에 기초한 개선된 RPP(복사열 보호 성능) 지수와 그의 측정방법을 제안하였다. 또한 제안된 열보호성능 측정 방법을 실험을 통해 확인하고, 보호복의 비정상열전달특성을 파악하였다. 또한 기존의 여러 가지 열보호성능지표들과 제안지표와의 관계를 제시하였다.

차등 3$\omega$ 기법을 이용한 다층 유전체 박막의 열전도도 측정 및 검증 (Measurement and Verification of Thermal Conductivity of Multilayer Thin Dielectric Film via Differential 3$\omega$ Method)

  • 신상우;조한나;조형희
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 2005
  • In this study, measurement of thermal conductivity of multilayer thin dielectric film has been conducted via differential 3$\omega$ method. Also, verification of differential 3$\omega$ method has been accomplished with various proposed criteria. The target film for measurement is 300 nm silicon dioxide and this thin film is covered with various thicknesses of upper protective layer. The upper protective layer is inserted between the target film and the heater line for purpose of electrical insulator or anti-oxidation barrier since the target film may be a good electrical conductor or a well-oxidizing material. However, the verification of differential 3$\omega$ method has not been conducted. Thus we have shown that the measurement of thermal conductivity of thin films with upper protective layer via differential 3$\omega$ method is verified to be reliable as long as the proposed preconditions are satisfied. Experimental results show that the experimental errors tend to increase with aspect ratio between upper protective layer thickness and width of the heater line due to heat spreading effect.

  • PDF

X선촬영실의 콘크리트 방어벽 두께 계산에 관한 연구 (A Study on Calculation of the Thickness of Concrete Protective Barrier of X-ray Radiographic Room)

  • 박철서
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.363-367
    • /
    • 2010
  • 본 연구의 목적은 X-선촬영장치의 1차방어벽두께 계산에 관한 쉬운 방법의 연구이다. X-선촬영장치에 대한 1차방어벽의 두께 계산을 위하여, 차폐물질은 콘크리트를 선택하였다. 방어벽의 구역들은 관리구역과 비관리구역으로 분류하였다. 두께의 계산은 NCRP 보고서 49와 51의 데이터를 사용하였다. 최대관전압 100과 150 kVp를 갖는 X-선촬영장치들에 대하여, 콘크리트 두께들은 거리의 함수로서 계산되었다. 계산된 데이터로부터, 식 (3), (4), (5), 그리고 (6)은 지수감소함수의 정합을 수행하여 얻었다. 본 연구에서 얻어진 수식들로부터, 1차방어벽의 두께는 근사적으로 계산할 수 있다.

차등 $3\omega$ 기법을 이용한 다층 유전체 박막의 열전도도 측정 및 검증 (Measurement and Verification of Thermal Conductivity of Multilayer Thin Dielectric Film via Differential $3\omega$ Method)

  • 신상우;조한나;조형희
    • 정보저장시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.85-90
    • /
    • 2006
  • In this study, measurement of thermal conductivity of multilayer thin dielectric film has been conducted via differential $3\omega$ method. Also, verification of differential $3\omega$ method has been accomplished with various proposed criteria. The target film for the measurement is 300 nm thick silicon dioxide which is covered with upper protective layer of various thicknesses. The upper protective layer is inserted between the target film and the heater line for purpose of electrical insulator or anti-oxidation barrier since the target film may be a good electrical conductor or a well-oxidizing material. Since the verification of differential $3\omega$ method has not been conducted yet, we have shown that the measurement of thermal conductivity of thin films with upper protective layer via differential $3\omega$ method is verified to be reliable as long as the proposed preconditions of the samples are satisfied. Experimental results show that the experimental errors tend to increase with aspect ratio between thickness of the upper protective layer and width of the heater line due to heat spreading effect.

  • PDF

Awareness of occupational hazards and personal protective equipment use among dental hygienists

  • Choi, Hyun-Ju;Hwang, Tae-Yoon;Jeon, Man-Joong
    • Journal of Yeungnam Medical Science
    • /
    • 제36권1호
    • /
    • pp.20-25
    • /
    • 2019
  • Background: The aim of this study was to evaluate the awareness of occupational hazards and personal protective equipment use among dental hygienists (DHs). Methods: A total of 271 self-administered questionnaires were obtained from 280 DHs working at dental hospitals or clinics in Daegu and Gyeongsangbuk-do, Korea. Results: The occupational hazards included work involving dust (94.1%), volatile substances (86.0%), noise (97.0%), and light-curing units (96.7%). The proportion of dental hygiene tasks that participants perceived as harmful were 42.4%, 51.7%, 9.2%, and 31.4% in the same order as above. The proportion of participants who used dust-proof masks during work involving dust was 1.1%. Those who wore gas-proof masks and gloves for work using volatile substances were 0.7% and 31.2%, respectively. Participants who used goggles for work involving light-curing units were 31.0%. None of the participants used ear plugs for work involving noise. A total of 22.9% of the participants recognized the Material Safety Data Sheet, while 79.7% had never been educated about harmful work environments. Conclusion: When compared to exposure status and perception of occupational hazards, the level of protective equipment use was very low. Extra measures to increase DHs' use of personal protective equipment are necessary.