• 제목/요약/키워드: Protective Mask

검색결과 74건 처리시간 0.022초

유해환경으로부터 개인의 안전보호를 위한 패션 마스크 디자인 경향 (A study on fashion mask design trends for individual safety protection from harmful environments)

  • 이달아;김찬호
    • 한국의상디자인학회지
    • /
    • 제24권4호
    • /
    • pp.101-116
    • /
    • 2022
  • The purpose of this study is to understand the trends of fashion mask designs as a fashion item with characteristics to protect individual health and safety from harmful environments. To this end, the concept, the trend analysis of the domestic and foreign mask markets, the type, characteristics of functional masks, and the design trend of fashion masks were analyzed. Research methods included case studies and literaturte on mask design, fashion magazines, fashion brand websites, fashion collections, and promotional material. First, masks for personal safety were classified as protective function masks from the natural environment, functional masks by industrial groups, masks for protective functions from biohazards, and masks for protective functions from various external activities. Through this analysis, the design trends of fashion masks were analyzed. The functional orientation of structure and functionality, the environmental orientation of sustainable eco-friendly methods, the fashion orientation of individual fashion styling, and the social functional orientation tend to transmit social messages. In the harmful environment of everyday life, items such as fashion masks with functionality and fashion characteristics should be continuously studied to integrate functional and design characteristics that can contribute to the future fashion industry and the fashion market as a sense of unity and responsibility.

보호마스크의 내부 부피에 따른 착용 평가 (Wear Evaluation of Protective Mask according to Internal Volume)

  • 엄란이;박선희;박소영;이예진
    • 한국의류학회지
    • /
    • 제44권4호
    • /
    • pp.626-638
    • /
    • 2020
  • In this study, protective masks were designed in varying internal volume and analyzed in regards to wearing effect. Masks were measured by surface temperature and subjective wear evaluation. Four experimental masks were created with an increasing distance between the mask center line and nose in increments. The distances were set at 0.0 cm (M0), 2.0 cm (M2), 4.0 cm (M4), and 6.0 cm (M6). The area and volume of each experimental mask was measured and both measurements had a positive correlation with the set distances. Among the experimental masks, M2 was the most breathable. The heat between the face and the mask created by exhalation was able to escape from the mask and provided the highest comfort sensation when worn. Conversely, an internal volume that is too large would decrease its comfort because repetitive breathing deforms the appearance of the mask and adversely affects its fit. Therefore, creating and maintaining the optimal internal volume of the M2 mask is important to achieve maximum thermal sensation and ease of wear.

저소음형 송기마스크 개발 (Development of a Low Noisy Type of Air-line Mask)

  • 백은규;김봉년;김광종
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

치과에서의 마스크 및 손의 미생물 오염정도 비교 (A Study of the Mask and Hand Contamination in Dental Clinic)

  • 표은지;이경희
    • 대한통합의학회지
    • /
    • 제7권3호
    • /
    • pp.85-94
    • /
    • 2019
  • Purpose: The purpose of this study was to observe the degree of mask contamination in dental hygienist for general and oral bacteria and to identify areas of mask contamination after treatment. Methods: Masks were collected with every fifty dental hygienists who currently working in the department of preventive dentistry, prosthodontics, and orthodontics in Busan. The mask bacteria were collected in specific upper and side parts of the mask. Hand germs were collected using sterile cotton swabs, and then placed in a sterile conical tube. These were transferred to the laboratory. Hand germs and mask bacteria were incubated with nutrient broth (NB) and brain heart infusion broth (BHI) for 24 hrs and each cultured with NB and BHI plate at $37^{\circ}C$ for 48 hrs. Collected data were analyzed using the SPSS Window 20. Results: The number of bacteria was observed in the order of the department of preventive dentistry ($10.1{\times}10^5CFU/ml$), prosthodontics ($14.7{\times}10^5CFU/ml$), and orthodontics ($23.3{\times}10^5CFU/ml$) in the hand. In general bacteria, the difference of contamination was seen by the parts of the mask, but there was no significant difference. However, the oral bacteria were observed highly contaminated upper part of the mask in preventive dentistry. The mask contamination according to the medical departments was observed. Especially, the contamination of mask in preventive dentistry was significantly higher than other departments in oral bacteria. Conclusion: This study suggested that correct mask replacement and recognition of contamination areas can contribute to the prevention of infectious disease. and it would be necessary to increase hand hygiene performance to prevent cross-infection with masks. Also, this study may give an idea for making guidelines for mask management and supporting to establish clear criteria for the education program of personal protective equipment.

Effect of Mask Wearing and Type on Cardiopulmonary Resuscitation Accuracy, Fatigue and Physiological Changes

  • Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Hee-Jeong Ahn
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권7호
    • /
    • pp.113-120
    • /
    • 2023
  • 본 연구는 심폐소생술 시 착용하는 마스크의 유형에 따라 심장압박의 정확도, 피로도 및 생리학적 변화를 파악하고자 한다. 연구는 2022년 5월 9일부터 12일까지 D대학교 응급구조과 재학생 중 BLS provider를 소지하고 있는 학생 총 24명을 대상자로 선정하여 수술 마스크(Dental mask), 미세입자 94%차단마스크(KF94 mask)를 각각 12명씩 착용하고 총 7회에 걸쳐 2분간 심폐소생술을 실시하였다. 연구 결과, 마스크 유형에 따른 구조자의 가슴압박의 질 분석에는 KF94를 착용한 그룹에서 압박속도(F=24.91, p<.001),와 손의 위치불량(F=14.54, p=.024)에서 유의한 차이를 보였고, 피로도를 분석한 결과에서는 Dental mask그룹(F=51.16, p<.001)과 KF94그룹(F=63.49, p<.001) 모두에서 유의한 차이를 보였다. 생리학적 변화를 분석한 결과에서 심박동수를 살펴보면, Dental mask그룹(F=34.79, p<.001)과 KF94그룹(F=35.55, p<.001) 모두에서 유의한 차이를 보였고, 호흡수 측정결과에서도 Dental mask그룹(F=25.02, p=.001)과 KF94그룹(F=23.03, p=.002) 모두에서 유의한 차이를 보였다. 따라서 현장활동의 가장 중요한 심폐소생술시에는 효율적인 가슴압박의 정확도와 구조자의 피로도 및 생리학적 변화의 감소를 위해서는 구조자의 유형에 따른 개인보호장비를 착용하는 것이 필요할 것이다.

생활형 보호마스크에 대한 소비자 불편사항 및 요구특성 분석 -자외선 차단마스크와 황사/미세먼지 차단마스크를 중심으로- (Research on Uncomfortableness and Customer Needs of Life-type Protection Mask -Focused on UV Protection Mask and Dust Protection Mask-)

  • 강여선
    • 한국의류학회지
    • /
    • 제40권1호
    • /
    • pp.114-130
    • /
    • 2016
  • This research provides practical data to develop UV protection masks and dust protection masks. It surveyed uncomfortable factors and significant characteristics for masks. It used 653 subjects 20-79 years old and performed the research from April to May in 2014. Wearing masks at outdoor activities is not widely popular yet, but golf players, mountaineers and old people were quite interested in masks. People mainly wore a basic shape mask, but main age group of each mask shape was different. People usually prioritized the protection function and comfort of wearing over design; however, women, young generation and people attending to outdoor activities longer than 1 hour considered design quite important. People going on picnic or camping consider mask characteristics most important. Therefore, various mask shapes and protective functions should be developed to reflect consumer needs. Meanwhile, the discomfort levels of masks were not too high, but old people felt more discomfort than young people. The most discomfort factors were 'other's eye', 'distracting face movement' and 'feeling of foreign object'. They also mentioned falling problem of C shape mask and short-rib shape mask, and asked for a 'tighter fit' at the ear.

Particle Filtration Efficiency Testing of Sterilization Wrap Masks

  • Chau, Destiny F.;O'Shaughnessy, Patrick;Schmitz, Michael L.
    • Journal of Preventive Medicine and Public Health
    • /
    • 제54권1호
    • /
    • pp.31-36
    • /
    • 2021
  • Objectives: Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as "N95 alternatives." This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control. Methods: A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted. Results: The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation. Conclusions: The sterilization wrap's particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.

일부 대학 내 연구실험실의 보호구 및 흄후드 관리 실태에 관한 연구 (A Study on the Status of Management for Personal Protective Equipments & Fume Hoods in University Research Laboratories)

  • 박인규;이사우;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.229-237
    • /
    • 2014
  • Objectives: This study intends to determine the current status of management of personal protective equipment fume hoods in university laboratories. Methods: A walk-through survey of 402 labs in Gyeongbuk Province and Daegu Metropolitan City were carried out between May 2009 and July 2010. Respectively, 348 and 54 laboratories were examined in Gyeongbuk Province and Daegu. Results: In size, labs serving over 15,000 student made up the majority with 276(66.4%). In terms of major, engineering labs were the highest in number with 100(24.9%). As to personal protective equipment, a gas mask and a dust mask were available in 17.8% and 14.3% of the labs, respectively, but 68.9% of labs were equipped with protective goggles. Meanwhile, only 12.7% of labs had separate protective equipment storage boxes. About 60% of the labs had installed a fume hood, of which the average capture velocity was 0.37 m/sec. Conclusions: For toxic substances, the labs are obliged to provide personal protective equipment in in accordance with the Occupational Safety and Health Act. In addition, the capture velocity of fume hoods must be in strict compliance in order to prevent occupational diseases due to toxic chemicals.

Nanoscale Processing on Silicon by Tribochemical Reaction

  • Kim, J.;Miyake, S.;Suzuki, K.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.67-68
    • /
    • 2002
  • The properties and mechanism of silicon protuberance and groove processing by diamond tip sliding using atomic force microscope (AFM) in atmosphere were studied. To control the height of protuberance and the depth of groove, the processed height and depth depended on load and diamond tip radius were evaluated. Nanoprotuberances and grooves were fabricated on a silicon surface by approximately 100-nm-radius diamond tip sliding using an atomic force microscope in atmosphere. To clarify the mechanical and chemical properties of these parts processed, changes in the protuberance and groove profiles due to additional diamond tip sliding and potassium hydroxide (KOH) solution etching were evaluated. Processed protuberances were negligibly removed, and processed grooves were easily removed by additional diamond tip sliding. The KOH solution selectively etched the unprocessed silicon area. while the protuberances, grooves and flat surfaces processed by diamond tip sliding were negligibly etched. Three-dimensional nanofabrication is performed in this study by utilizing these mechanic-chemically processed parts as protective etching mask for KOH solution etching.

  • PDF

일개지역 치과위생사의 감염관리 실태에 관한 연구 (Actual status of infection control by the dental hygienist in Korea)

  • 윤경옥
    • 한국치위생학회지
    • /
    • 제13권3호
    • /
    • pp.369-376
    • /
    • 2013
  • Objectives : The objectives of this study is to investigate the handwashing and use of personal protection equipment in dental hygienists and provide the basic data for dental infection control guideline. Methods : A questionnaire survey was performed in the dental hygienists who participated in the continuing education by the Daejeon City Commission in October 2012. The collected data were analyzed using PASW 18.0. Results : Handwashing was well practiced in group working for 3 to 5 years of employment. Those who took the infection cnotrol training used liquid soap, paper towel, dental mask, protective goggles, face shield, and gloves. Conclusions : Infection control is the most important practice in dental hygienists. So it is necessary to emphasize the inportnace of personal protection equipment including medical gloves, dental mask, and goggles.