• 제목/요약/키워드: Protective Mask

검색결과 75건 처리시간 0.027초

휴식과 운동 중 COVID-19 대응 보건용 마스크 착용이 호흡·심혈관계 반응 및 착용감에 미치는 영향 (Effects of Wearing COVID-19 Protective Face Masks on Respiratory, Cardiovascular Responses and Wear Comfort During Rest and Exercise)

  • 정재연;강찬혁;성유찬;장세혁;이주영
    • 한국의류산업학회지
    • /
    • 제22권6호
    • /
    • pp.862-872
    • /
    • 2020
  • This study explores the effects of facemasks on respiratory, thermoregulatory, cardiovascular responses during exercise on a treadmill and at rest. Five male subjects (25.8 ± 0.8 y, 171.8 ± 9.2 cm in height, 79.8 ± 28.1 kg in weight) participated in the following five experimental conditions: no mask, KF80, KF94, KF99, and N95. Inhalation resistance was ranked as KF80 < KF94 < N95 < KF99 and dead space inside a mask was ranked as KF80 = KF94 < N95 < KF99. The surface area covered by a mask was on average 1.1% of the total body surface area. The results showed no significant differences in body core temperature, oxygen consumption (VO2), carbon dioxide production (VCO2), heart rate or subjective perception among the five experimental conditions; however, cheek temperature, respiratory ventilation and blood pressure were greater for KF80 or KF94 conditions when compared to KF99 or N95 conditions (p<0.05). The differences among mask conditions are attributed to the dead space or specific designs (cup type vs pleats type) rather than the filtration level. In addition, the results suggest that improving mask design can help mitigate respiratory resistance from increased filtration.

중소규모 사업장의 교육 환경과 고용형태에 따른 호흡보호구 인식도 및 밀착계수 비교 (Comparison of Recognition and Fit Factors according to Education Actual Condition and Employment Type of Small and Medium Enterprises)

  • 어원석;최영보;신창섭
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.28-36
    • /
    • 2018
  • There was a difference in recognition of respirators according to the educational performance environment. they were showed higher recognition of respirators of group by internal and external mix trainer, less than 6 months, over 1hour, more than 5 times, variety of education. To identify the relationship between types of job classification(typical and atypical)and the levels of recognition of respirators, a total of 153 workers in a business workplace. mainly, typical workers showed higher recognition of respirators than atypical workers. Training of correct wearing showed high demands both typical and atypical workers. Descriptive statistics(SAS ver 9.2)was performed. the results of recognition of respirators were analyzed the mean and standard deviation by t-test, and anova, fit factor is used geometric means(geometric standard deviation), paired t-test, Wilcoxon analysis(P=0.05). Particulate filtering facepiece respirators (PFFR) is one of the most widely used items of personal protective equipments, and a tight fit of the respirators on the wearers is critical for the protection effectiveness. In order to effectively protect the workers through the respirators, it is important to find and evaluate the ways that can be readily applicable at the workplace to improve the fit of the respirators. This study was designed to evaluate effects of mask style (cup or foldable type) and donning training on fit factors (FF) of the respirators, since these are available at various workplace, especially at small business workplace. A total of 40 study subjects, comprised of employment type workers in metalworking industries, were enrolled in this study. The FF were quantitatively measured before and after training related to the proper donning and use of cup or foldable-type respirators. The pass/fail criterion of FF was set at 100. After the donning training for the cup-type mask, fit test were increased by 769%. but foldable-type mask was also increased after the donning training, the GM of FF for the foldable-type mask and it's increase rate were smaller as compared to the cup-type mask. Furthermore, the differences of the increase rates of the GM of FF in employment type of the subjects were not significantly for the foldable-type mask. These results imply that the raining on the donning and use of PFFR can enhance the protection effectiveness of cup or foldable-type mask, and that the training effects for the foldable-type mask is less significant than that for the cup-type mask. Therefore, it is recommended that the donning training and fit tests should be conducted before the use of the PFFR, and listening to workers opinion regularly.

화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발 (Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment)

  • 가동하
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

구리 보호층을 이용한 전해에칭에서의 다층구조 제작 (Fabrication of Multilayered Structures in Electrochemical Etching using a Copper Protective Layer)

  • 신홍식
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.38-43
    • /
    • 2019
  • Electrochemical etching is a popular process to apply metal patterning in various industries. In this study, the electrochemical etching using a patterned copper layer was proposed to fabricate multilayered structures. The process consists of electrodeposition, laser patterning, and electrochemical etching, and a repetition of this process enables the production of multilayered structures. In the fabrication of a multilayered structure, an etch factor that reflects the etched depth and pattern size should be considered. Hence, the etch factor in the electrochemical etching process using the copper layer was calculated. After the repetition process of electrochemical etching using copper layers, the surface characteristics of the workpiece were analyzed by EDS analysis and surface profilometer. As a result, multilayered structures with various shapes were successfully fabricated via electrochemical etching using copper layers.

Protective role of Ginseng in endomertriosis during covid-19

  • JiHyeon Song;YoungJoo Lee
    • Journal of Ginseng Research
    • /
    • 제47권2호
    • /
    • pp.169-172
    • /
    • 2023
  • The coronavirus disease 2019 (COVID) pandemic began in December 2019. Many countries have implemented restrictions such as mandatory mask wearing and social distancing. These measures have caused diverse and complex health problems, particularly in women's health, anxiety, and depression. This review examines an alternative approach to the treatment of endometriosis during the COVID pandemic. The efficacy of ginseng with anti-inflammatory activity and ability to relieve or prevent symptoms of endometriosis is discussed and reviewed.

방진마스크의 Stainless steel arc 용접흄 여과효율에 관한 연구 (A Study on Filtration Efficiency of Several Dust Masks for Stainless Steel arc Welding fume)

  • 송경석;권용식;한규태;정규혁;이용묵;유일재
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.42-47
    • /
    • 2001
  • The purpose of this study was to investigate for filtration efficiency of several dust masks, comparing with filtration efficiency certified by KOSHA(Korea Occupational Safety & Health Agency), and to require of the right use of protective respirators. Using a welding fume generator and chamber, several dust masks, which were widely used in the workplaces in korea, were tested for their filtering efficiency for stainless steel arc welding fume. The filtration efficiency testing system consisted of a welding fume generator, a chamber and a filtration unit. The filtration unit was made of a mask which was inserted into the sampling cassette and another sampling cassette, which contained mixed cellulose ester filter paper. These two cassettes were connected with tubing. Stainless steel arc welding fume generator was delivered into an chamber. The welding fume in the chamber was passed into the filtration unit with flow rate of 30 liter/min. The welding fume filtration efficiency was evaluated by gravimetric measurement. Metal concentrations in the welding fume before and after filtration were measured with inductive coupling plasma analyzer. Following results were obtained: Filtration efficiency of welding fume for common hygienic mask was 63.82% and the average efficiencies for A, B, C, D, E, F and G masks were 94.62%, 96.58%, 83.20%, 82.76%, 77.25%, 86.55% and 93.22%, respectively. Our results indicate that dust masks used widely in the welding workplaces in korea are not proper for protecting worker's health and then the use of fume mask should be required.

  • PDF

작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향 (Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask)

  • 이진실;조선희;윤정민;김민선;박재규;최재호
    • 품질경영학회지
    • /
    • 제46권2호
    • /
    • pp.301-310
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using 'Respirator Fit Tester 8038' which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(${\alpha}=0.01$). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

일부 산(Acid)에 폭로된 근로자의 치아산식증에 관한 조사연구 (A STUDY ON THE DENTAL EROSION BY ACID AMONG WORKERS EXPOSED TO ACID)

  • 배정수;이재휘;임현술;정해관;장동수
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.368-377
    • /
    • 1994
  • In order to investigate the oral health status including dental erosion, the authors had surveyed and oral examined 510 male workers, among whom 199 workers were exposed to acids and 311 were not exposed to acids, in a factory using acids during the period from November, 26 to 27 in 1992. The obtained results were as follows ; 1. The positive rate of dental erosion between the acid exposed and non-exposed group didn't show statistical difference. But the positive rate of degree 1 dental erosion by degree was statistically high in the acid exposed group(P<0.05). 2. The acid exposed group showed the higher positive rate of degree 1 dental erosion in lower incisors by site(P<0.01). 3. To the average number of eroded teeth, the acid exposed group showed more degree 1 eroded teeth in lower incisors than the non-exposed(P<0.05). 4. Although the rate of dental erosion was increased according to the increase in tenure in both exposed and non-exposed group(P<0.05), there was no difference in rate of the dental erosion by site among the same tenure group. 5. In the acid exposed group, the rate of dental erosion between protective mask wearer group and non-wearer group was not statistically different, but upper incisors of the protective mask wearer group showed lower rate of dental erosion by site(P<0.05). 6. The positive rate of periodontal diseases was higher in the acid exposed group(P<0.01).

  • PDF

방사능 방호 제품에 대한 KOLAS 인증 방안 연구 - 마스크를 중심으로 (Study on KOLAS Certification Approach for Radiation Protection Products - Focusing on Masks)

  • 박남희;여욱현;홍성진
    • 한국재난정보학회 논문집
    • /
    • 제19권4호
    • /
    • pp.815-825
    • /
    • 2023
  • 연구목적: 본 논문은 방사선비상계획구역 내 거주하는 주민의 방사능재난 발생시 대피과정에서 사용할 수 있는 방호제품으로서 마스크를 개발하는 과정에서 KOLAS 인증을 받을 수 있는 방안을 연구하는 것이다. 연구방법: 각종 보고서와 논문, KOLAS 인정기구 및 각종 마스크 홈페이지 자료를 조사하여 연구하였다. 연구결과: 국내 방사능재난방재대책을 수립하여 주민보호조치를 강화하고 있으나 방호제품 보급은 갑상샘방호약품이 유일하다. 방사능재난에 대비하여 마스크와 같은 보조적인 지원용품 보급이 필요하다. 방호마스크를 공인인증할 수 있는 KOLAS 인정 공인기관이 없는 실정이다. 결론: 성능 인증 기준이 있는 마스크의 경우 산업용 방진마스크로 공인시험성적서를 발급받고 인증을 받은 후에 자체 기준으로 일반성적서를 받는 이중 과정을 거쳐서 마스크의 KOLAS 인증이 가능하다.

농약방제복 착용실태 및 만족도에 관한 연구 (A Study on the Wearing Condition and Satisfaction of Pesticide Protective Clothing)

  • 오영순;이경숙;채혜선;김경란;김성우
    • 한국의상디자인학회지
    • /
    • 제16권4호
    • /
    • pp.217-228
    • /
    • 2014
  • The purpose of this study is to grasp inconveniences and improvements by examining wearing condition and satisfaction of protective clothing targeting 114 Korean farmers and to suggest basic data for enhancement of pattern and wearing satisfaction of protective clothing by understanding problems of pesticide-proof clothing through comparative analysis on the size of its commercial products. Most of male subjects were in charge of spraying pesticide, whereas female were most likely to play an assistant role to hold the hose of pesticide applicator. Both of female and male subjects were very aware of the harmful effect of pesticide on human body and tried to take off the clothes immediately after spraying it to reduce possible damage caused by pesticide. As a result of examining wearing condition, the farmers avoided wearing protective clothing because that it feels hot, stuffy, and uncomfortable to move. This hesitant response of wearing the clothing was not shown significantly in case of female subjects who play an assistant role for spraying. Although the farmers wore protective equipments such as mask or gloves in a proper way as compared to protective clothing, they seemed to choose alternative way rather than best way to block pesticide completely. The satisfaction regarding to the fitting of protective clothing which the subjects showed low in all items of upper-lower clothes except waistline. It is necessary to improve the functionality such as relief from heat stress and convenience for movement rather than design or economic in protective clothing development. As a result of comparing the size of five kinds of commercial protective clothing, the farmers got confused to choose the product since designation method of size across companies showed a significant difference in an identical clothing size. In addition, the sizing system developed on a basis of a well-built man has become a hindering factor in wearing satisfaction of female farmers.

  • PDF