• 제목/요약/키워드: Protective Device

Search Result 273, Processing Time 0.041 seconds

Protection of MOV Thermal Runaway and Safety Improvement of SPD using Built-in Instantaneous Trip Device (내장 순시 트립장치를 이용한 MOV의 열폭주 보호와 SPD의 안전성 개선)

  • Kim, Ju-Chul;Jeon, Joo-Sool;Ki, Che-Ouk;Choi, Gyung-Ray;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.120-125
    • /
    • 2011
  • SPDs are increasingly being used against lightning and switching surge according to the applicable revised standard and equipotential grounding system. SPDs are equipped usually with a MOV voltage regulating element. The MOV, however, always is exposed to the danger of thermal runaway resulting from inrushing temporary overvoltage and deterioration. In this paper, the authors made two prototype SPDs built-in Instantaneous trip device and analyzed their limiting voltage through test of the MOV breakdown. As the result of the analysis, the SPDs built-in Instantaneous trip device was proven to be effective for protecting MOV against thermal runaway and Instantaneous trip device react for limiting voltage is considered that is applicable to SPD.

A Wearable Safety Device for the Body Protection of Motorcyclists (모터사이클 운전자 신체보호용 안전장치 개발 프로세스)

  • Jang, Dong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.25-33
    • /
    • 2021
  • This paper presents the development process for airbag safety devices fitted in motorcyclists' garments. Motorcycle riders often sustain multiple injuries in crashes since rider post-impact kinematics depend on several variables. This study proposes a newly inflatable safety system connected to the motorcycle by a cable. An airbag device with a mechanical triggering system is deployed when the cable detaches from its mounting clip. Airbag filling tests are performed to determine the mixing ratio of compressed gases with the severance of temperature. To estimate the airbag effectiveness to reduce riders' injuries, numerical analysis is performed using the finite element method. A comparative analysis (i.e., with and without the chosen device) was conducted to evaluate its protective efficacy. Prototype garments based on the proposed design have been created and have undergone sled tests. The proposed safety device could also be beneficial in accidents during other sports activities.

Design and Fabrication of a Surge Protective Device for Electrical Mains on Shipboard (전원회로용 서지방호장치의 설계 및 제작)

  • Moon, Seung-Bo;Park, Dae-Won;Song, Jae-Yong;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1035-1040
    • /
    • 2005
  • This paper deals with the design rule and performance results of the surge protective devices (SPDs) for low-voltage mains on shipboard. The proposed SPDs consists of a metal oxide varistors (MOV) and a L-C filter to improve noise-elimination performance. Three kinds of SPDs are fabricated and tested by using a combination surge generator which produce the standard impulse current of 8/20${\mu}s$ 2.1kA. As a results, the proposed SPDs with series L-C filter have more excellent transient blocking and noise reduction performance than the conventional ones.

  • PDF

Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller (UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템)

  • Suh, Jung-Nam;Jung, Chang-Ho;Cho, Jong-Man;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

A Study on the Diagnosis Method considering Harmonics Flow (유입, 유출에 따른 고조파 전류 해석 방법 연구)

  • Jung, Hae-Sung;You, Sang-Bong;Lee, Il-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1461-1462
    • /
    • 2015
  • Based on the Kepco's standard supply terms, the customer should pay for installation the regulating device or protective device which are granted by Kepco in case the customer hinder other customer's electricity usage or it may cause the interruption because of harmonics or waveform distortion. It is necessary to consider the phase angle of voltage, current for harmonics so we can set up the measure of harmonic damages.

  • PDF

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

Realtime Digital Monitoring and Controller Development for Power Systems (전력시스템의 실시간 디지털 중앙감시 및 제어장치 개발)

  • Jong-Dug Cho;Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1517-1522
    • /
    • 2001
  • In this paper, We propose digital protective relay which monitors the status of distribution line and controls power apparatus with real time operation. Digital protective relay improves the performance of basic functions which are measurement, display and communication. The Int one we consider is that the protective device has the standard method for protecting the distribution systems which are circuit brakers, switch and emergency generators. These are Protected by analog type Protective relay and devices. The security requirements should be activated within a few seconds, and with real time operation. The second one is an efficient method for adapting the one chip micro-processor(PIC16F84) which is enable to digital control system. The proposed methods are implemented with experimental results and have an high fidelity characteristics in local experiment tests.

  • PDF

Evaluation of Thermal Comfort on Protective Clothing Worn in an Radiation Power Plant

  • Kim, Eun-Joo;Han, Myung-Sook;Lee, Won-Ja
    • The International Journal of Costume Culture
    • /
    • v.3 no.1
    • /
    • pp.30-40
    • /
    • 2000
  • The purpose of this research was to device thermal comfort model for radiation power plant workers in protective clothing. Three fabrics commonly used in protective workwear were made into coveralls of identical design and were evaluated by adult healthy males in four simulated work environment. It was investigated between the physiological response and subjects comfort according to environmental variance and clothing types. The of simulated work enviro mensent was controlled under four different humidity and temperature of each type. (Temperature 20±1℃, RH 40∼70%±5%, Temperature 30±1℃, RH 40∼70%±5%) An index of physiological response was connected with the thermal comfort designed. Mean skin temperature, skim temperature, Axillasy temperature ear canal temperature, clothing climate, total sweat, blood pressure, and R-R interval were be evaluated. Skin temperature difference ocurring during exercise and rest were significant only with respect to time and regions of the body, This despite physical differences in the three coveralls, particulary mass statistically experiment. Also, an index of subject wearing sensation was designed for thermal comfort after investigation determined the kind of clothes and the type of environment. As a result of this research, two types of multiple regressions was deviced to estimate thermal comfort of the protective clothing.

  • PDF

A study of coordination under short-circuit conditions between circuit-breakers (저압차단기의 차단보호협조 특성연구)

  • Oh, J.S.;Na, C.B.;Ham, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.476-478
    • /
    • 2001
  • Coordination under short-circuit conditions is a systematic application of protective devices in the electrical power system, which, in response to a fault, will remove only a minimum amount of equipment from service. The objective is not only to minimize the equipment damage and process outage costs, but also to protect personnel from the effects of these failures. The coordination study of an electric power system consists of an organizes time-current study of all devices in series from the utilization device to the source. This study is a comparison of the time it takes the individual devices to operate when certain levels of normal or abnormal current pass through the protective devices. The objective of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices that will ensure that the minimum unfaulted load is interrupted when the protective devices isolate a fault or overload anywhere in the system. At the same time, the devices and settings selected should provide satisfactory protection against overloads on the equipment and interrupt short-circuit as rapidly as possible.

  • PDF

Surge Protective Device(1) (서지보호장치(1))

  • Lee, Gi-Hong
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.68-71
    • /
    • 2012
  • 금년부터 SPD가 KS제품으로 인정받을 수 있게 됩니다. 이러한 기술적 환경변화에 따라 SPD 기술에 대한 이해를 돕고자, 금번 호부터는 SPD에 대해서 연재하도록 하겠습니다.

  • PDF