• Title/Summary/Keyword: Protective Device

Search Result 273, Processing Time 0.037 seconds

A FPGA Implementation of Digital Protective Relays for Electrical Power Installation (전력설비를 위한 디지털보호계전기의 FPGA 구현)

  • Kim, Jong-Tae;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.131-137
    • /
    • 2005
  • Protective relays provide important features to electrical power systems for protecting against faults and consequent short circuits. This research presents a novel VLSI design of the digital protective relay, which overcomes today's uP/DSP-based relays. This design features good cancellation of DC/k-th harmonic components, noticeable not performance and flexible Protection behavior in the minimized core area The proposed design was successfully implemented by a FPGA(Field Programmable Gate Array) device and can concurrently process over 16KSPS at less $0.03[\%]$ error rate.

Accuracy Analysis of Construction Worker's Protective Equipment Detection Using Computer Vision Technology (컴퓨터 비전 기술을 이용한 건설 작업자 보호구 검출 정확도 분석)

  • Kang, Sungwon;Lee, Kiseok;Yoo, Wi Sung;Shin, Yoonseok;Lee, Myungdo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.81-92
    • /
    • 2023
  • According to the 2020 industrial accident reports of the Ministry of Employment and Labor, the number of fatal accidents in the construction industry over the past 5 years has been higher than in other industries. Of these more than 50% of fatal accidents are initially caused by fall accidents. The central government is intensively managing falling/jamming protection device and the use of personal protective equipment to eradicate the inappropriate factors disrupting safety at construction sites. In addition, although efforts have been made to prevent safety accidents with the proposal of the Special Act on Construction Safety, fatalities on construction sites are constantly occurring. Therefore, this study developed a model that automatically detects the wearing state of the worker's safety helmet and belt using computer vision technology. In considerations of conditions occurring at construction sites, we suggest an optimization method, which has been verified in terms of the accuracy and operation speed of the proposed model. As a result, it is possible to improve the efficiency of inspection and patrol by construction site managers, which is expected to contribute to reinforcing competency of safety management.

Assessment of Equipotential Bonding and Electrical Continuity in Buildings (건축물의 등전위 본딩 및 전기적 연속성 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.385-386
    • /
    • 2009
  • This paper deals with assessment of equipotential bonding and electrical continuity in Buinding by investigation on the spot at construction site. The assessment was carried out for continuity of steelwork in reinforced concrete structure, bonding conductor, protective conductor. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding, use of surge protective device.

  • PDF

Tribology Characteristics on the Atmospheric Pressure of Alumina Ceramics with Different Purity (순도를 달리한 알루미나 세라믹스의 분위기 압력변화에 따른 Tribology 특성)

  • Jin, Dong-Gyu;Park, Heung-Sik;Seo, Yeong-Baek;Ok, Cheol-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.448-454
    • /
    • 2000
  • This study was undertaken to investigate tribological characteristics with atmospheric pressure for three alumina ceramics of different purity, such as, 85 %, 95 % and 99.7 %. The wear test was carried out using the wear test device which was designed for this study in air, $10^-2$ Torr and $10^-4$ Torr. The friction coefficient depends entirely on atmospheric pressure and alumina with lower purity than higher purity has been much affected by heat accumulation. The friction surface of ceramics have been protected in the air by the influence of the oxides transferred from STB2. However, the protective layer can not be formed due to the decrease of oxygen in vacuum.

Monitoring of Retrofitted Reinforced Concrete Beams with Hybrid Fiber Reinforced Polymer (광섬유 센서를 이용한 복합 섬유 재료로 보강된 철근 콘크리트 보의 모니터링)

  • 이옥기;신영수;김기수;김종우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.509-514
    • /
    • 2001
  • The Fibre-optic Bragg grating (FBG) sensor is broadly accepted as a structural health monitoring device for Fibre reinforced plastic (FRP) materials by either embedding into or bonding onto the structures. The accuracy of the strain measured by using the FBG sensor is highly dependent on the bonding characteristics among the bare optical fibre, protective coating, adhesive layer and host material. In general, the signal extracted from the embedded FBG sensor should reflect the straining condition of the host structure. This paper presents a theoretical model to evaluate the differential strains between the bare fibre and host material with different adhesive thickness and modulus of the protective coating of the embedded FBG sensor.

  • PDF

Optimal Operation Methods of Protection Devices in Distribution Systems with PV Systems (태양광전원의 연계에 의한 배전계통 보호기기의 최적 운용방안에 관한 연구)

  • Kim, Byeon-Gi;Park, Jae-Beom;You, Kyeong-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1485-1491
    • /
    • 2011
  • This paper deals with the technical problems for the protection devices, by simulating test facilities of protection coordination for Photovoltaic systems. In order to analyze the operation characteristics for the protection devices in the case that the Photovoltaic systems with bi-directional power supply are located in the feeder, this paper proposes the test facilities composed of model distribution system, protection device and model Photovoltaic systems. By performing the simulation for operation characteristics for the protection devices based on the test facilities, this paper presents the malfunction mechanism for the protection devices. The test results show that this paper is practical and effective for the technical guideline for the Photovoltaic systems.

LAN-Based Protective Relaying for Interconnect Protection of Dispersed Generators (LAN을 이용한 분산전원 연계 계통의 보호)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.491-497
    • /
    • 2007
  • As dispersed generators was driven in condition interconnecting with utility, it could cause a variety of new effects to the original distribution system that was running as considered only the one-way power flow. Therefore, the protection devices that is builted in distribution system should be designed to be able to operate with disposing of not only a fault of the generator, but also utility condition. Especially, the fault of the feeder interconnected with Dispersed Generator can cause the islanding phenomenon of open DG(Dispersed Generators). This phenomenon has many problems such as a machinery damage, electricity qualify degradation and a difficulty of the system recovery. In the fault therefore, we must separate Dispersed Generator from the system quickly. In this paper, for the fault classification of the interconnected DG and the outside feeder we judge the fault of the interconnected DG and the outside feeder in HMI through data provided by IED(Intelligent Electronic Device) on the network and decide whether it operates or not by sending the result to each relay.

A Study on the Deterioration Progress of Railway Arresters (철도용 피뢰기의 열화진전에 관한 연구)

  • Kil Gyung-Suk;Han Ju-Seop;Han Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1393-1395
    • /
    • 2004
  • Arresters are the best protective device on electrical power systems against transient overvoltages generated by lightning and/or switching operation. Nonetheless, arresters will be deteriorated due to absorption of moisture in the environments of its use, repetition in the protective operation to overvoltages, and some defects at manufacturing. It is therefore important to estimate the electrical characteristic changes of ZnO blocks. In this paper, an accelerated deterioration test by a standard lightning impulse current was carried out to extract parameters needed for diagnosing arrester deterioration, and leakage current components were measured. Total energy applied to the ZnO blocks at each time is 1,050[J] in 8/20[${\mu}s$] impulse current. From the experimental results, we proposed electrical parameters and leakage current level to diagnose arrester soundness.

  • PDF

Survey of Damage Cases for Surge Protective Devices Installed Electrical Communication Systems and Analysis of Degradation Diagnosis Method (전자통신설비의 SPD 소손사례 및 열화진단기법 분석)

  • Lim, Jong-Wook;Lee, Jae-Young;Kwon, June-Hyuk
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.15-18
    • /
    • 2009
  • In recent years electric devices and telecommunication facilities were often damaged by surge generated lightning discharge. When the service was interrupted by failure of electrical devices due to surge the social loss is very enormous. Therefore in order to protect electrical systems against lightning, SPDs(Surge protective device) have been used But damaged SPDs often make some troubles like fire and interrupt of service. In this work, 3rd harmonic leakage current defection method was applied as the diagnosis of SPD degradation and the effectiveness of this method was verified by field survey.

  • PDF

A Development of Power System Protection Database Management System for Computerized Integrated Environment (계통 보호 종합 전산화를 위한 데이터베이스 관리 시스템 개발)

  • Jung, B.K.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, H.P.;Lee, W.H.;Choi, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1475-1477
    • /
    • 1999
  • The setting of protective relays, which is critical to the system security, requires a huge volume of data and a lot of repetitive calculations. Therefore computerization of this process, named PROSET2000 is in progress in KEPCO. PROSET2000 is based on a power system protection database. The database must accomodate a variety of protective device data efficiently, which need be viewed and updated with ease. This paper suggests several database management functions for PROSET2000.

  • PDF