• 제목/요약/키워드: Protection system

검색결과 5,936건 처리시간 0.036초

A Protection Ratio with Composite Fade Margin for Detailed Frequency Coordination in Microwave Relay System Network

  • Suh, Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • 제7권2호
    • /
    • pp.83-90
    • /
    • 2007
  • In this paper, the formulation of the protection ratio based upon a composite fade margin and availability is newly presented for the detailed planning of frequency coordination in the microwave relay system network, and computed results for co-channel and adjacent channel protection ratios are illustrated over an actual system with 6.2 GHz. It is shown that the protection ratio to assure a quality of service can be expressed in terms of the composite fade margin, noise-to-interference ratio, net filter discrimination, and system parameters. In addition, the net filter discrimination, depending upon the transmitter spectrum mask and the overall receiver filter characteristic, has been examined to investigate the effect of the adjacent channel protection ratio caused by the adjacent channel interference. Regarding simulated results for 6.2 GHz, 60 km, 64-QAM, and N/I=6 dB at the bit error rate of $10^{-6}$, composite fade margin and co-channel protection ratio yield 25.14 and 50.3 dB, respectively. Also, the net filter discrimination of 26.5 dB and the adjacent channel protection ratio of 23.8 dB are obtained at the first adjacent channel of 30 MHz. The proposed method provides some merits in view of a comprehensive and practical application with more detailed and various system parameters needed to access the criteria for making the proper frequency coordination.

소방전문자격사제도의 개선에 관한 연구 - 소방시설관리사를 중심으로 - (A Study on the Reformation of Certified Fire Fighting Specialists - Focused on Fire Protection System Managers -)

  • 오형근
    • 한국방재학회 논문집
    • /
    • 제6권4호통권23호
    • /
    • pp.21-28
    • /
    • 2006
  • 이 연구는 특정소방대상물의 소방시설에 대한 자체점검을 수행하는 소방시설관리사의 운용실태를 분석하고 개선방안을 제시하였다. 도시 공설소방서비스로 소방검사를 보완하는 자체점검을 수행하는 소방시설관리사를 대상으로 직무환경, 제도환경, 운용환경 등에 대해 설문조사를 실시하여 소방시설관리사제도의 운용실태에 대한 문제점을 실증적으로 파악하였다. 연구에 나타난 결과는 자체점검에 대한 법적 제도적 장치미비로 건물주와 소방검사원 그리고 소방시설관리사 상호간에 갈등이 있는 것으로 나타나 제도정착을 위해서는 상호보완 협력적 관계를 정립해야 할 것으로 나타났다.

350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구 (A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line)

  • 이학표;서기범;박재영
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

Numerical analysis results of the cathodic protection for the underground steel pipe by anode installation method

  • Jeong, Jin-A;Choo, Yeon-Gil;Jin, Chung-Kuk;Park, Kyeong-Wan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1212-1216
    • /
    • 2014
  • This study aims to find out the best anode location for buried pipelines. Numerical simulation program known as CATPRO (Elsyca, Belgium) were used for confirming the best location of anodes and the effects of impressed current cathodic protection system. Applied conditions for numerical simulation were similar to on-site environmental conditions for optimal application of cathodic protection system. Used criterion of cathodic protection was NACE SP 0169, which describes that minimum requirement for cathodic protection is -850mV vs. CSE. Various layouts for anodes' installation were applied, which were distance between anodes, anode installation location, and applied current. The areas where cathodic protection potential was lower than -850mV vs. CSE was limited up to 50m from anode installation locations. It was founded numerical analysis obtain cost-effective and efficient cathodic protection methods before design and application the impressed cathodic protection system to on-site environment.

경호기법에 입각한 경호무도의 학문적 접근 (A study on approach thesis of protection martial arts)

  • 박준석
    • 시큐리티연구
    • /
    • 제6호
    • /
    • pp.103-122
    • /
    • 2003
  • Protection sciences are new science. therefore, protection martial arts sciences are will studied be based on study of protection in order to supply high level by request. Moreover, It is reconstruction that protection martial arts masters education, systematic manage, certificate system, protection martial arts recognition certificate, protection martial arts equipment, practice of protection martial arts. Protection martial arts occurs on the unforeseen accident and body guarding, therefore martial arts concept of protection martial arts different general martial arts and sport. In order to develope of protection martial arts First, scientific thesis need of protection martial arts learning. Especially, aims of present protection martial arts is not protect oneself, protect the VIP to safely from all dangers is different thing with aims of general martial arts. Instinct that VIP protect rather than oneself should study and develop. Second, techniques and model of protection martial arts spread to who in connection with security service by systematic and organized. Preferentially, study of protection martial arts Techniques and model possible the protection martial arts learned society, found laboratory and endowed protection martial arts society organize and prevention for random of protection martial arts and must make the original protection martial arts. Third, protection martial arts official certificate and license system must organize in order to training and manage of protection martial art master, Match director(First Second), life physical director(First, Second, Third) is systematically manage by Ministry of Culture & Tourism Republic of Korea. Like this protection martial arts also classify the certificate by scholarship and experience. Fourth, In union to university, private security service company, public institution, police and system that possible leaning to protection martial arts certificate course important. In addition, destroy the commercial character of present martial arts and cultivate the pure martial arts mind, should develop to martial arts in order to improve the humanism and temperament of right body guard.

  • PDF

대규모건축물적용 특수방재설비

  • 이성모
    • 한국화재소방학회논문지
    • /
    • 제10권4호
    • /
    • pp.37-42
    • /
    • 1996
  • The "Intelligent Fire detecting and Extinguishing System" is an up-to-date fire protection system for modern high-rise buildings, international airports, enormous industrial facilities, dome stadiums such as specific areas in which the application of our local fire protection regulation could not be satisfied. The state-of-the art initiating devices communicated with sophisticated network control panels enable peoples to get reliable and powerful suppressions using water or gas, providing absolute protection. The Intelligent Water Cannon System, the Low Pressure $CO_2$ System and the MXL Networking Fire Alarm System introduced in this paper accomplish the dynamic protection for the special hazards.

  • PDF

The Performance of Cathodic Protection with ICCP

  • Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1286-1290
    • /
    • 2004
  • This paper describes the anti-corrosion system on underwater structures of ships. Metals and alloys have several positions in the series such as immunity, corrosion and passivity. The iron potential has to change from the corrosion position to the anodic protection or cathodic protection for preventing corrosion by providing corrosion protection system such as ICCP(Impressed Current Cathodic Protection). The purpose of ICCP system is to eliminate the rusting or corrosion, which occurs on metal immersed in water. The system includes a power supply unit, which consists of a transformer, a converter. a controller, etc. This paper presents the protection performance of ICCP under dynamic condition such as velocity. The variation of potential and current density with time and environment factors are also described Finally, the experimental results will be explained and analysed.

초전도케이블이 병입된 계통의 고장에 대한 보호협조 검토기법 (A study result on coordinative protection method of HTS cable implemented distribution system)

  • 이현철;양병모;이근준
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.700-704
    • /
    • 2011
  • This paper proposes a coordinative protection study results of 22.9kV HTS(High-Temperature Superconducting) cable implemented distribution system. HTS cable can provide about 5 times larger transfer capacability compare to conventional XLPE cable, however, it has different heat characteristic so called quench. This paper presents the simulation results on Ichun substation HTS cable which connects main transformer and 22.9kV bus. Various expected fault cases are considered and discussed to examine whether conventional protection scheme is effective to protect both of existing facilities and HTS cable. With the results of simulation, conventional protection scheme can be used if instantaneous element and time inverse elements could be adjusted with proper time coordination. Internal temperatures of HTS cable conductor in safe region with proper protection without quench. This results are to be demonstrated by the field test and will be implemented in Ichon substation HTS cable protection and control system.

낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구 (A Study on the Effective Surge Protection Method from Induced Lightning Surgeto Improve Isolate Grounding to Common Grounding)

  • 전형구;우제욱;서용준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1459-1467
    • /
    • 2011
  • 본 논문은 낙뢰 Surge 방호를 위하여 독립접지를 공통접지로 개선하는 효율적인 방법을 제안하였다. 낙뢰 Surge 방호를 위해서는 등전위 이론에 근거하는 공통접지방식이 적합하고, 중성선이 있는 전원계통에서는 공통접지방식을 사용하는 것이 국제적으로 통용되는 기술규격이다. 따라서 낙뢰 Surge에 취약한 문제점을 갖고 있는 기존의 중성선이 없는 전원계통과 독립접지방식을 중성선이 있는 전원계통과 공통접지방식으로 개선을 하고, 정전압소자를 이용하여 낙뢰 Surge를 방호하는 효율적인 등전위 시스템 구축 방법을 제안한다.

  • PDF

우주비행기 열보호 시스템의 설계 및 개발 현황 (Design and Development Status of a Thermal Protection System for a Spaceplane)

  • 윤용식;최기혁
    • 항공우주시스템공학회지
    • /
    • 제12권3호
    • /
    • pp.79-85
    • /
    • 2018
  • 지구 재진입 비행체와 태양계 행성의 대기권 진입 비행체의 개발 요구가 증가하고 있다. 일반적으로 대기권 진입에는 대기 항력과 가열 환경이 동반하여 이에 따른 열보호 자재의 선정과 열보호 시스템의 설계와 적용이 매우 중요하다. 본 논문에서는 대기권 진입 환경과 우주 비행기의 열보호 자재의 종류와 특징을 고찰하였다. 그리고 우주비행기에 사용하는 열보호 시스템의 설계 및 활용 현황 등에 대하여 기술하였다.