• Title/Summary/Keyword: Protection system

Search Result 5,910, Processing Time 0.039 seconds

Measures and Proposal for Korean Solar Water Heating System (한국형 태양열 온수급탕 시스템의 대책과 제안)

  • Kim, Sung-Soo;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.631-636
    • /
    • 2008
  • Solar thermal systems are recently refocused by higher oil prices, but did not completely restore the people's confidence owing to the past bad systems. Several types of solar water heating systems were analyzed in characteristics and some proper systems were proposed under Korean climates and system scale. As a small system, natural circulation system should be installed only in a southern region of Korea, with a freeze protection valve instead of heating coil for freeze protection. In most area of Korea, the forced circulation type with a heat exchange coil inside a thermal storage tank or with a spiral-jacketed storage tank, proposed and verified by the authors, has a merit of stable performance and freeze protection.

Determination of Low-temperature Electrochemical Properties of Selected Cation-exchange Membranes for Cathodic Protection Analysis

  • Ko, Moon-Young;Kwon, Byeong-Min;Hong, Byung-Pyo;Byun, Hong-Sik
    • Korean Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.8-12
    • /
    • 2008
  • The electrochemical properties of Nafion type membranes as a function of temperature to examine the key factors affecting the cathodic protection process at low temperatures was investigated in this study. Variable temperature experiments for AC impedance, DC resistance were conducted. The resistances of 3 Nafion membranes (N 324, N 450, N MAC) were measured in 30% KOH (aq) for a range of temperatures between $-30^{\circ}C$ and room temperature. Membrane resistance increases exponentially with decreasing temperature. This behaviour is most significant at operational temperatures below $0^{\circ}C$. These membranes are stable under the low temperature and caustic conditions of the heat exchange system, but they place a much higher restriction on the cathodic protection of the stainless heat exchange stack. N 450 has the lowest AC impedence and DC resistance at temperatures below $0^{\circ}C$ and consequently is most suitable membrane of the three, for low temperature applications.

Cybersecurity Risk Assessment of a Diverse Protection System Using Attack Trees (공격 트리를 이용한 다양성보호계통 사이버보안 위험 평가)

  • Jung Sungmin;Kim Taekyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.3
    • /
    • pp.25-38
    • /
    • 2023
  • Instrumentation and control systems measure and control various variables of nuclear facilities to operate nuclear power plants safely. A diverse protection system, a representative instrumentation and control system, generates a reactor trip and turbine trip signal by high pressure in a pressurizer and containment to satisfy the design requirements 10CFR50.62. Also, it generates an auxiliary feedwater actuation signal by low water levels in steam generators. Cybersecurity has become more critical as digital technology is gradually applied to solve problems such as performance degradation due to aging of analog equipment, increased maintenance costs, and product discontinuation. This paper analyzed possible cybersecurity threat scenarios in the diverse protection system using attack trees. Based on the analyzed cybersecurity threat scenario, we calculated the probability of attack occurrence and confirmed the cybersecurity risk in connection with the asset value.

A Study on Shortcircuit Fault Protection Method Using Rogowski Coil (Rogowski 코일을 이용한 과전류 폴트 차단 기법에 관한 연구)

  • Yoon, Hanjong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.108-110
    • /
    • 2018
  • This paper proposes shortcircuit fault protection method in a synchronous buck converter using the PCB pattern Rogowski coil. The PCB pattern Rogowski coils are embedded in the gate driver to measure the device currents of the top and bottom side. When shortcircuit occurs in the system, the gate signal is blocked by the proposed fault protection method using the device current. The simulation and experimental results show that the proposed fault protection method is verified in the shortcircuit system.

  • PDF

The Practice and Effect of Water Conservation Legislation in China

  • Liu, Dingxiang;Li, Jianguo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.19-19
    • /
    • 2012
  • After more 60 years' legislative practice of water resources protection, the Chinese government has initially established a legislative system of water resources protection, based on Water Law. From the development course of water resources protection legislation, the paper mainly analyzes the legal framework, main content & management system of water resources protection, and pointed out the improved direction of water resources conservation legislation in China in the future.

  • PDF

Design of SPS in the Korean Power System Against Faults on 765 KV Lines

  • Park Jong-Young;Park Jong-Keun;Jang Byung-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.132-137
    • /
    • 2005
  • In Korea, the protection systems against the instability of the nation's power system are insufficient in contrast with many other countries. In addition, there have just been studies carried out on detecting power system instability, while only a few studies pertaining to protection plans against instability exist. This paper focuses on systems to protect against the instability phenomena in the Korean power system. In this paper, we survey possible contingencies in the Korean power system and suggest outline and specs of the SPS (System Protection Scheme) against faults on the 765 kV line, based on simulations. It is concluded that event-based SPS for transient stability is appropriate for the Korean power system. In the simulations, the most severe contingency on the Korean power system is the fault on 765 kV transmission lines. If one of these lines is tripped by a fault, synchronism may be lost on the power plants near this line because of heavy power flow carried by them. In addition, undervoltage in the Metropolitan region is a serious problem in this case since this region receives about half its total power flow through these lines. In order to prevent a synchronism loss, some power plants have to be rejected according to the situations in the simulations.

Rapid Corrosion Test on Marine Reinforcing Steel (부식촉진에 의한 해양.항만 철근 콘크리트 구조물의 철근 방식에 관한 실험적 연구)

  • 정근성;문홍식;송호진;이상국;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.537-542
    • /
    • 2001
  • Recently long-span bridges, such as Kwang-Ahn Grand bridge, Seo-Hae Grand Bridge, Young-Jong Grand Bridge, etc, have been designed and constructed near the shore. It needs to maintain the durability of marine concrete structures which are exposed to severe chloride environments. It is well known that corrosion of reinforcement steels in concrete structure is the most important cause for the durability of concrete structure which can be controlled by systematic preparatory corrosion protection works for economic and safe infrastructures. Various corrosion protection systems have been used for the corrosion protection of reinforcement steels from detrimental chemical components such as chloride, sulphate and etc. Since chloride can be penetrated into concrete in a variety way, an effective method has to be adopted by taking into full economical aspects and technical data of each protection system. The objective of this experimental study is to investigate the corrosion behavior of reinforcing steel in laboratory concrete specimens which are exposed to cyclic wet and dry saltwater, and then to develop pertinent corrosion protection system, such as corrosion inhibitors and cathodic protection for reinforced concrete bridges exposed to chloride environment. Resistance of various corrosion inhibitors and impressed current system have been experimentally evaluated under severe environmental conditions, and thus effective corrosion protection systems could have been Practically developed for future concrete construction.

  • PDF

Current Status of Internal Dosimetry Methods and Radiological Regulations in Korea, Ukraine and European Community

  • Lee, Tae-Young;Lee, Jong-Il;Berkovski, Vladimir
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.65-73
    • /
    • 2003
  • The paper discusses results of recent international intercomparison exercises on internal dose assessments, status of up to date internal dosimetry methods and the radiological legislation developed and implemented in Korea, European Union and Ukraine. The system of radiation protection in Korea is based on the Korean Atomic Energy Regulatory Enforcement on Safety Standards (Ministry Notice No. 2001-2). The notice is based on the recommendations in ICRP Publication 60 (1990) and IAEA Basic Safety Standards (1996). But the full implementation of the notice by the end of the year 2002 is not required because of the socio-economic situation and inexperience in internal radiation dosimetry Regulatory framework for internal radiation dosimetry is under development toward the full implementation of the notice from January 1, 2003. The system of radiation protection in Ukraine is based on the National radiation protection regulatory code NRBU-97. The code was developed and adopted in 1998 and replaced the Regulations of Former Soviet Union. The document is based on the ICRP Publication 60, Euratom Directive 96/29 and IAEA Basic Safety Standards (1996). The transitional period of 5 years (effected till January 2003) is established for implementation of all requirements of this new regulation. The system of radiation protection in the European Community is based on the Council Directive 96/29/Euratom, adopted in 1996 and enforced from 13 May 2000. Directive 96/29/Euratom has the status of the European law.

Flexible Barrier System for Rockfall Protection (유연성 방호책을 이용한 철도변 낙석방호사례)

  • 최승일;유병옥;김경석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.103-116
    • /
    • 2003
  • Rockfall Protection fence is one of the most common rockfall Protection methods in Korea. If rockfall protection fences are required along the road or railway, their location, height and capacity, in terms of the maximum kinetic energy that they can absorb, should be specified. Within this paper, the best practice of rockfall barrier is introduced. Modern rockfall simulations as a means to define risks, protection requirements, dynamic loading and height of potential structures and selection of appropriate placement is presented. Technical possibilities of rockfall barriers and their actual limits are presented. Safety concepts based on probabilistic approaches are proposed. Recent studies peformed in other countries show that Flexible Barriers are also a feasible system to stop and retain debris flows. Finally an outlook onto further development is given.

  • PDF

Evaluation of Corrosion Protection for Epoxy and Urethane Coating by EIS under Various Cyclic Corrosion Tests

  • Hyun, Jonghun;Shon, Minyoung
    • Corrosion Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.95-100
    • /
    • 2011
  • Protective coatings play an important role in the protection of metallic structures against corrosive environment. The main function of anticorrosive coating is to prevent the materials from corrosive agents, such as water, oxygen and ions. In the study, the corrosion protection properties of urethane and epoxy coating systems were evaluated using EIS methods exposed to the corrosion acceleration test such as Norsok M501, Prohesion and hygrothermal cyclic test. AFM analysis of the coating systems was carried out to monitor the change of roughness of coatings. Urethane coating system was more stable than the epoxy coating under given cyclic conditions. Water uptake into the urethane coatings was less than that into the epoxy coating. The urethane coating system showed better corrosion protection than epoxy coating system based on the changes of the impedance modulus at low frequency region with exposure time. Consequently, the corrosion protection properties of the epoxy and urethane coatings was well correspond with their surface roughness changes and water uptakes.