• 제목/요약/키워드: Protection setting

검색결과 248건 처리시간 0.054초

기술기준에 의한 거리계전기 정정시 고려사항 검토 (Considerations Review on Setting of Distance Relay using Technical Standards)

  • 문수철
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1141-1145
    • /
    • 2018
  • Generally, in nuclear plants, distance relay (21R) has adapting to protect and to operate main protective of transmission lines and backup protective of main generator. Operation of 21R was required and based on exactly accurate calculation and criteria. But presently method of 21R setting has applied according to protection devices operation guide of KPX, excepting IEEE and ISA standards, which have a difference review directions, consider parameters and devices, also consideration factors were affected to relay operations by uncertain guides. therefore this paper proposed new protection relay setting method and unvague criteria from IEEE 741 and ANSI/ISA 67.04.01, and reviewed a different results through numerical calculation results for methods and criteria including previous and established 21r setting by IEEE, ANSI/ISA Technical standards.

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

한국전력 송전계통 보호 데어터베이스 구축 (A Development of Power Transmission System Protection Database for Korea Electric Power Company)

  • 안영태;이승재;최면성;강상희;김호표;이운희;최홍석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.847-854
    • /
    • 1999
  • The setting of protective relays, which is critical to the power system security and reliability, requires a huge volume of data processing and repetitive calculation. Since it has been performed by relay engineers manually, it is vulnerable to human errors, its computerization has been pursued, in which the efficient management of the data is the key to the success. The database for power system protection must accommodate not only the power system network data but also a variety of protective devices. Also its information should be able to be viewed and updated with easy by operators and by computer programs. This paper describes several existing database designs for power system protection, their advantages and disadvantages. Also this paper has identified the required function and designed the database for the KEPCO power system data structure for the benefit of the relay setting process, etc..

  • PDF

화력발전소의 발전기 보호계전기의 정정에 관한 연구 (A Study on Generator Protection Relay Setting in Thermal Power Plant)

  • 최순철;이경민;박철원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.569-570
    • /
    • 2015
  • Power plants by coal-fired generators in 00 Thermal Power site Division came the most developed environmental system in the world. This paper examined with respect to the setting of the first grade protection relay.

  • PDF

배전자동화용 보호협조프로그램 개선 (The upgrade of coordination program for distribution automation system)

  • 설일호;하복남;박신열;정영범;이상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.629-631
    • /
    • 2005
  • The DASPRO (Protection Coordination Program for DAS) is one of the application programs for Distribution Automation System (DAS) of the KEPCO. Application programs developed by KEPCO provide optimal operation in distribution network. The DASPRO includes diverse functions to operate network as construction of database using existing information. creation of diagram for protection coordination. calculation of fault current. evaluation network. power quality monitoring, etc. The DASPRO can examine validity of setting values for protective devices by comparing to T-C curves. Unless the protection coordination is correct, the most suitable setting value for protection devices are displayed on the screen. In this paper, I will introduce the contents of the DASPRO.

  • PDF

THE METHOD FOR SETTING DESTINATION BASED ON IDENTIFIER OF MOVING OBJECT

  • Jang, In-Sung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.107-110
    • /
    • 2008
  • In this study, we propose a system for setting a Destination on CNS(Car Navigation System) or PNS(Personal Navigation System). The present Navigation does set the destination by only static method like name search, address search and wire telegraph telephone number search. But, the kind of setting a static destination does not reflect the dynamic moving situation. So we suggest setting the destination of navigation using Identifier of moving terminal. And it includes privacy protection on personal position information

  • PDF

UML(Unified Modeling Language)기법을 이용한 PCM전류차동계전기 정정모듈 개발 (Development of PCM Current Differential Relay Setting Module Using UML)

  • 오태욱;오성민;민병운;이승재;최면송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.329-331
    • /
    • 2003
  • PROSET2000 that is integrated protective management system had developed and used in order to automate the setting process of protective relays in transmission system protection. PROSET2000 have database for relay setting and automated for relay setting program within. This paper proposed PCM current differential relay setting program point of Object Oriented Programming paradigm using Unified Modeling Language about additional relay in PROSET2000. Nevertheless each relay uses same current differential but setting method is different. This paper discribed different thing about setting method of each relay and evaluated more effective and corrective relay setting program using UML.

  • PDF

소수력 발전시스템을 위한 IED의 정정치에 관한 연구 (A Study on Setting of IED for Small Hydro Generation System)

  • 안태풍;박철원
    • 전기학회논문지P
    • /
    • 제66권1호
    • /
    • pp.15-20
    • /
    • 2017
  • In order to advance and improve the performance of domestic aged power plants, IEDs have been developed for power generation systems. For smooth installation and operation of the protection relays, a detail settings study of IED is required. This paper deals with an analysis based on PSCAD and setting investigation of IED for loss of field, reverse power protection in Small Hydro Generation System.

FACTS적용계통에서의 송전용량 평가 알고리즘 (An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device)

  • 윤용범;윤종수;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

효율적인 계통보호 데이터베이스 디자인 방법에 관한 연구 (A Study of an Effective Database Design Method for Power System Protection)

  • 안영태;최면송;이승재;강상희;김호표;최흥석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.905-907
    • /
    • 1998
  • The setting of protective relays, which is critical to the system security, requires a huge volume of data and a lot of repetitive calculations. Since an effective design of a database is essential. The relay setting database must accommodate a variety of protective devices. Also its information can be viewed and updated with easy by humans and by computer programs. This paper describes several existing database designs for power system protection, their advantages and disadvantages. Also this paper develops an effective database for power system protection with their advantages.

  • PDF