• Title/Summary/Keyword: Protection performance

Search Result 2,157, Processing Time 0.029 seconds

A Report on Test Results of Pressure Operated Switch (압력스위치 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

Characteristics of N-Type Extended Drain Silicon Controlled Rectifier ESD Protection Device (NED-SCR 정전기보호소자의 특성)

  • Seo, Y.J.;Kim, K.H.;Lee, W.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1370-1371
    • /
    • 2006
  • An electrostatic discharge (ESD) protection device, so called, N-type extended drain silicon controlled rectifier (NEDSCR) device, was analyzed for high voltage I/O applications. A conventional NEDSCR device shows typical SCR-like characteristics with extremely low snapback holding voltage. This may cause latchup problem during normal operation. However, a modified NEDSCR device with proper junction / channel engineering demonstrates itself with both the excellent ESD protection performance and the high latchup immunity.

  • PDF

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

Effects of Replacement of Soybean Meal by Fermented Cottonseed Meal on Growth Performance, Serum Biochemical Parameters and Immune Function of Yellow-feathered Broilers

  • Tang, J.W.;Sun, H.;Yao, X.H.;Wu, Y.F.;Wang, X.;Feng, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.3
    • /
    • pp.393-400
    • /
    • 2012
  • The study was conducted to examine the effects of partially replacing soybean meal (SBM) by solid-state fermented cottonseed meal (FCSM) on growth performance, serum biochemical parameters and immune function of broilers. After inoculated with Bacillus subtilis BJ-1 for 48 h, the content of free gossypol in cottonseed meal was decreased from 0.82 to 0.21 g/kg. A total of 600, day-old male yellow-feathered broilers were randomly divided into four groups with three replicates of 50 chicks each. A corn-SBM based control diet was formulated and the experimental diets included 4, 8 or 12% FCSM, replacing SBM. Throughout the experiment, broilers fed 8% FCSM had higher (p<0.05) body weight gain than those fed 0, 4 and 12% FCSM. The feed intake in 8% FCSM group was superior (p<0.05) to other treatments from d 21 to 42. On d 21, the concentration of serum immunoglobin M in the 4% and 8% FCSM groups, as well as the content of complements (C3, C4) in 8% FCSM group were greater (p<0.05) than those in the SBM group. Besides, birds fed 8% FCSM had increased (p<0.05) serum immunoglobin M, immunoglobulin G and complement C4 levels on d 42 compared with bird fed control diet. No differences (p>0.05) were found between treatments regarding the serum biochemical parameters and the relative weights of immune organs. In conclusion, FCSM can be used in broiler diets at up to 12% of the total diet and an appropriate replacement of SBM with FCSM may improve growth performance and immunity in broilers.

The effect of levels of open innovation activity on innovation performance: Focusing on the mediating effect of technology protection (개방형 혁신활동의 수준이 혁신성과에 미치는 영향: 기술보호의 매개효과를 중심으로)

  • Park, Yuan;Lee, DaYoung;Cho, KeunTae
    • Journal of Technology Innovation
    • /
    • v.29 no.4
    • /
    • pp.31-57
    • /
    • 2021
  • This study explores the effect of open innovation activities on innovation performance by dividing into two dimensions of breadth and depth of open innovation activity, and it also verifies the mediating effect of technical protection between open innovation activities and innovation performance. In order to examine the hypothesis, it has surveyed 1,403 companies of manufacturing and service with experience in producing innovative results. The results find that the breadth of open innovation activities has a positive effect on the achievement of radical innovation, and the depth of open innovation activities brings a positive effect on the achievement of incremental innovation. The verification result of the mediating effect of technology protection indicates that partially mediated between the breadth of innovation activities and radical innovation activities, and in the case of the depth, it is completely mediated. The results of this study provide the crucial implications not only for the company promoting open innovation, but especially also for the companies promoting product innovation by acquiring technology.

Evaluation of the Protection Performance of SB4 Class Concrete Barrier with Anti-Glare Function (SB4 등급 방현기능 콘크리트 방호울타리의 방호성능 평가)

  • Joo, Bongchul;Hong, Kinam;Yun, Junghyun;Lee, Jaeha;Kim, Jungho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.93-102
    • /
    • 2021
  • This paper describes the process of developing a concrete median barrier of SB4 grade with anti-glare function. The development section has a height and width of 1,270mm and 560mm, respectively. A wire mesh is placed in the center of the cross section to improve the protection performance. Collision analysis predicted that this section satisfies the strength and occupant protection performance, and that no damage to the barrier occurs. In the actual collision test, it was confirmed that this section satisfies the strength and occupant protection performance. However, damage was observed on two concrete barrier when the truck crashed. In order to improve the accuracy of the collision analysis of the concrete barrier in the future, it is considered that a study on the model development and continuous collision analysis method for domestic commercial vehicles should be carried out.

Practical suggestions for development of 『manned & unmanned complex combat performance plan』 (drone operation) (『유·무인복합전투수행방안』 발전을 위한 현실적 제언(드론 운용))

  • Cheol-jung Kim;Bo-Ram, Kim;Min-Youn Kim;Jae-Seok Lim
    • Journal of Internet Computing and Services
    • /
    • v.25 no.1
    • /
    • pp.137-146
    • /
    • 2024
  • drones are used in a variety of fields, including business, leisure, lifesaving, and war. Various research using drones is being conducted in the military. In particular, the use of drones in 『Manned-Unmanned Complex combat performance plan』, powered by various unmanned vehicles deployed in the Army TIGER system, is expected to be a major factor realizing the Army's future combat performance that minimizes damage to ally combat troops while causing maximum damage to the enemy. As the deployment of various systems progresses, combat performance methods utilizing each system are evolving, but there is a lack of research to identify and resolve limitations in the perspective of unmanned vehicle operators. Based on the Ukrainian military's FPV drone combat case, we would like to make suggestions from the operator's perspective on overcoming perspective limitations through the introduction of FPV and the designation of military drone frequency.

Convergence Study on Perception and Performance of Patient Private Information Protection in Nursing Students with Clinical Practice (임상실습 경험 간호학생의 환자 개인정보보호 인식과 실천에 대한 융합적 연구)

  • Lee, Hyun-Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • The purpose of this study was to research the perception and performance of patient private information protection(PPIP) of 76 nursing students with clinical practice of 18 weeks. The mean score of perception on PPIP (4.62 points/5 points) was significantly higher than the performance(3.84 points/5 points). There was a statistically significant positive correlation between perception and performance. In the future, it is necessary to study the interdisciplinary convergence study to understand the factors affecting the perception and performance of PPIP of nursing students and to Develope and apply of PPIP education program for nursing students. Also it is necessary to seek joint plans between medical institutions and universities to improve the perception and performance of PPIP.