• Title/Summary/Keyword: Protection of equipment

Search Result 762, Processing Time 0.029 seconds

Collision Hazards Detection for Construction Workers Safety Using Equipment Sound Data

  • Elelu, Kehinde;Le, Tuyen;Le, Chau
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.736-743
    • /
    • 2022
  • Construction workers experience a high rate of fatal incidents from mobile equipment in the industry. One of the major causes is the decline in the acoustic condition of workers due to the constant exposure to construction noise. Previous studies have proposed various ways in which audio sensing and machine learning techniques can be used to track equipment's movement on the construction site but not on the audibility of safety signals. This study develops a novel framework to help automate safety surveillance in the construction site. This is done by detecting the audio sound at a different signal-to-noise ratio of -10db, -5db, 0db, 5db, and 10db to notify the worker of imminent dangers of mobile equipment. The scope of this study is focused on developing a signal processing model to help improve the audible sense of mobile equipment for workers. This study includes three-phase: (a) collect audio data of construction equipment, (b) develop a novel audio-based machine learning model for automated detection of collision hazards to be integrated into intelligent hearing protection devices, and (c) conduct field experiments to investigate the system' efficiency and latency. The outcomes showed that the proposed model detects equipment correctly and can timely notify the workers of hazardous situations.

  • PDF

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

A theoretical study on the shock-absorbing characteristic of safety helmet (안전모의 충격전달에 관한 이론적 고찰)

  • 김연우;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.29-33
    • /
    • 1990
  • The need for the protection of workers in many industrial workstations has long been recognized, and many type of protective equipment have been devised. In many protective equipment designs, this study set limits to the safety helmet. The direct closed head impact problem was idealized as a linear-damped spring model. This study concerns what properties of helment should afford optimal protection in a direct closed head impact problem. The solution to the problem was achieved through analytic method and numerical computation. The answer was found in terms of 4 parameters : 1) rigidity of shell, 2) viscosity of shell, 3)rigidity of harness, 4) viscosity of harness. The choices are as follows 1) to reduce the rigidity value of harness as small as possible 2) to increase the viscosity value of harness as large as possible. 3) to select the rigidity value of shell sufficient for preventing a breakage.

  • PDF

Electrical Machines and Drives for Potentially Explosive Atmospheres

  • Grantham, Colin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • This paper gives an overview of the requirements for electrical equipment in potentially explosive atmospheres and describes how these are applied to electrical machines and drives in hazardous areas. The method by which equipment can be shown to be safe in a whole range of gases, by testing in a single test gas, is covered. It is shown how the more recently introduced methods of protection for hazardous areas, increased safety and nonsparking, are ideally suited to AC machines and drives. A novel method of measuring the fullload temperature rise of electrical machines for hazardous, and other areas, without the need to connect a mechanical load to the machine's drive shaft is explained.

Protecting electronic equipment against lightning surge (옥외용 전자장비의 낙뢰 서지 대책)

  • 임순재;이주광;이완규;최만용
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 1997
  • Precision electronic equipments for outdoor use are composed of sophisticated microcircuits that are extremely vulnerable to lightning-caused voltage spike. This transient voltage spike may cause upset, latent failure or Interference on electronic equipments. In order to develop efficient lightning protection measures on AC power lines of a road traffic controller as a electronic equipment for outdoor use, experimental surge immunity tests were conducted according to IEC standard 801-5. The combination of gas tube arrester and metal-oxide varistor was installed at the input of AC power lines and the silicon avalanche suppressor installed at the output of DC power supply for the lightning protection measures.

  • PDF

A Study on the Transient Phenomenon Protection System Development for Fire Alarm System Control Unit (화재 수신기용 과도현상 보호시스템 개발에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.55-61
    • /
    • 2009
  • This study has been carried on the transient phenomenon protection system to become fire alarm system control unit of high reliance which can be protected from transient phenomena for surge or transient overvoltage, and constructed engineering base that can develop transient phenomenon protection system by proving performance of protection system in a experimental. This study developed 1 step and 2 step protection system that can be protected from transient phenomenon with process thesis and theory for development of transient phenomenon protection system. It established engineering data construction and a source technology that can develop transient phenomenon protection system as gets satisfied result and test with all performance condition that present in fire protection law and connection regulation.

A Study on Installation of Monitoring System of Wireless Power Transmission System (무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

Personal Protective Equipment Availability and Utilization Among Interventionalists

  • Rose, Andre;Rae, William Ian Duncombe
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.166-171
    • /
    • 2019
  • Objective: This study explored personal protective equipment (PPE) availability and PPE utilization among interventionalists in the catheterization laboratory, which is a highly contextualized workplace. Methods: This is a cross-sectional study using mixed methods. Participants (108) completed a survey. A hyperlink was sent to the participants, or they were asked to complete a paper-based survey. Purposively selected participants (54) were selected for individual (30) or group (six) interviews. The interviews were conducted at conferences, or appointments were made to see the participants. Logistic regression analysis was performed. The qualitative data were analyzed thematically. Results: Lead glasses were consistently used 10.2% and never used 61.1% of the time. All forms of PPE were inconsistently used by 92.6% of participants. Women were 4.3 times more likely to report that PPE was not available. PPE compliance was related to fit and availability. Conclusions: PPE use was inconsistent and not always available. Improving the culture of radiation protection in catheterization laboratories is essential to improve PPE compliance with the aim of protecting patients and operators. This culture of radiation protection must include all those involved including the users of PPE and the administrators and managers who are responsible for supplying sufficient, appropriate, fitting PPE for all workers requiring such protection.

A Study on the Grounding Resistance Effects of Lightning Arrester for Lightning Stroke Protection in Electric Distribution Systems (배전계통에서 낙뢰보호용 피뢰기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.107-114
    • /
    • 2010
  • Lightning is the discharging of high-voltage charged cells within clouds to earth other or to the earth. Lightning protection grounding is essential for the protection of buildings, distribution lines, and electrical equipment from lightning surges. Equipment grounding is for the purpose of controlling the voltage to earth within predictable limits. This paper investigates the effects of lightning arrester grounding resistance by analysing the neutral to earth voltages and arrester break down voltages when the lightning strike hits the distribution line. The case study was simulated numerically and graphically through the use of the EDSA software program.

Development and Application of Digital D.C Protection Relay for the test line of Light Rail Transit (경량전철 시험선로의 디지털 직류보호제어장치 개발 및 적용)

  • JEON Y.J.;KIM S.N.;KIM J.H.;BAEK B.S.;LEE H.D.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1373-1375
    • /
    • 2004
  • This paper presents the design of DC protection Relay for Light Rail Transit system, which is very beginning product in domestic. Protection Function characteristic, principle and I/O interface including interlock signal has been introduced. The protection algorithm and EMC characteristics have been certified by official organization and Type test report has been introduced. Up to date in domestic, the test procedure for DC Protection relay hasn't been established so the new method and test equipment based on IEC regulations are proposed. Finally the product will be proved based on field test.

  • PDF