• Title/Summary/Keyword: Protection of equipment

Search Result 762, Processing Time 0.028 seconds

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.

A Efficient Network Security Management Model in Industrial Control System Environments (산업제어시스템 환경에서 효과적인 네트워크 보안 관리 모델)

  • Kim, Il-Yong;Lim, Hee-Teag;Ji, Dae-Bum;Park, Jae-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.664-673
    • /
    • 2018
  • The industrial control system (ICS) has operated as a closed network in the past, but it has recently been linked to information and communications services and has been causing damage due to cyber attacks. As a countermeasure, the Information Communication Infrastructure Protection Act was enacted, but it cannot be applied to various real control environments because there is only a one-way policy-from a control network to a business network. In addition, IEC62443 defines an industrial control system reference model as an international standard, and suggests an area security model using a firewall. However, there is a limit to linking an industrial control network, operating as a closed network, to an external network only through a firewall. In this paper, we analyze the security model and research trends of the industrial control system at home and abroad, and propose an industrial control system security model that can be applied to the actual interworking environments of various domestic industrial control networks. Also, we analyze the security of firewalls, industrial firewalls, network connection equipment, and one-way transmission systems. Through a domestic case and policy comparison, it is confirmed that security is improved. In the era of the fourth industrial revolution, the proposed security model can be applied to security management measures for various industrial control fields, such as smart factories, smart cars, and smart plants.

The Study about Improvement of Neuro Energy Decreased by Energy Saving (에너지절감에 의해 감소되는 뉴로에너지의 증강에 관한 연구)

  • Kim, Myung-Ho;Kang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.715-721
    • /
    • 2018
  • This study examined energy saving and elevating the worker's neuro energy (comfort, concentration, physical, and psychological stability) by compensating for the unpleasant tactile sensation to stimulate auditory and olfactory senses and reduce energy consumption. The experiment was conducted in an environment test room under the test conditions of temperature $25[^{\circ}C]$, relative humidity 50[RH%], illumination 1,000[lux] and air current speed 0.02[m/sec] by stimulating the auditory senses with a 1/f change in rhythm and the olfactory senses with an aroma scent. The experiment utilized the method of EEG, which evaluates human body's psychological status via tactile means, and the method of the vibra image, which evaluates the learning abilities, HRV and human body's psychological status via non-tactile means. The subjects were selected as eight university students (four males and four females) in their 20s, the type that have high relative ${\alpha}$(8~13[Hz]) activation in occipital lobe, which brings the highest level of mind stability and concentration, who had no difficulty in physical activities. The subjects' posture and physical activity was fixed to 1met - when the subjects are seated and relaxing in a comfortable environment - and their clothes condition was standardized as 0.7clo. As a result, the sentimental and psychological stability and concentration were the highest in the multisensory stimulation of jasmine scent and change rhythm of an a=1.106 sound source. In addition, under this condition, the relative $M{\alpha}$ and relative $M{\beta}$ increased by 70.49[%] and 89.72[%], respectively; the HRT decreased by 39.09[%]; and the fatigue and tension/anxiety decreased by 36.85[%] and 15.54[%], respectively.

Experimental Study on the Self-extinguishing Performance of Extruded Polystyrene Insulation for Buildings and Suggestions on Institutional Management (건축용 압출법 단열판(XPS)의 자기소화성에 대한 실험적 연구 및 제도적 관리에 관한 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.141-149
    • /
    • 2020
  • The Korea Industrial Standards (KS) stipulates methods and test procedures for measuring the horizontal combustibility of cellular plastics exposed to small flames (KS M ISO 9772:2018) and recommendations regarding the magnetic digestion of extruded polystyrene insulation (XPS) for measurement results (KS M 3808:2020). Although products that are certified to conform to KS standards must have burning characteristics (self-extinguishing), they are incinerated and spread by welds at construction sites, causing significant human and property damages. In this study, XPS produced by five companies, certified by KS, and sold in the market were purchased and tested for ignition and diffusion caused by a weld bullion at a construction site. The results showed that the five products had differences in performance. Three out of the five products were found to be self-saturated, but the other two were easily ignited and diffused, making it difficult for them to be self-extinguishing. Based on the result of this experimental investigation in line with the KS regulations, all the three types of products, including two types of products that were incinerated through weld defects, were found to be non-self-extinguishing, as specified in KS M 3808.

Analysis of Safety Contents in the High School Science Textbooks Based on the 2015 Revised National Science Curriculum (2015 개정 고등학교 과학 교과 교과서에 제시된 안전 관련 내용 분석)

  • Lee, Seyeon;Lee, Bongwoo
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.4
    • /
    • pp.563-571
    • /
    • 2019
  • The purpose of this study is to analyze the safety contents presented in high school science textbooks of the 2015 revised national science curriculum. For these, we found safety contents in the inquiries and appendices of 63 science textbooks: integrated science, science inquiry experiment, physics I, II, chemistry I, II, biology I, II, and earth science I, II. We analyzed these safety contents using six safety factors based on the seven standards for safety education. The main results are as follows: First, 81(46.0%) inquiries among 176 curriculum inquiries contain safety contents, and these contents are mainly found in chemistry textbooks, and the least in 'science inquiry experiment' textbooks. Second, safety contents are found the most in 'laboratory safety rule', followed by 'safety symbol' and 'usage of protection equipment'. Third, the safety contents of appendices are mainly in 'laboratory safety rule' and 'accident treatment'. Based on these results of this study, it is concluded that these textbooks have problems; that there is a big difference in describing safety contents in each textbook; that these safety contents are not presented in detail and that the educational effect is reduced. Furthermore, the safety symbol is not standardized. We also discussed ways to improve the safety contents of science textbooks.

A study on the application of drone in firefight field (소방분야의 드론 활용방안 연구 경향 분석)

  • Ha, Kang Hun;Kim, Jae Ho;Choi, Jae Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.321-330
    • /
    • 2021
  • By reviewing domestic and international papers, this study examines various fields in which drones are used, and based on the results, fields are suggested in which drones can be used for the work of firefighters. Overall, the research results show that drones are most commonly used for search (51%), disaster and fire monitoring (35%), and delivery (14%). Specifically, in the search field, using a drone is more efficient in terms of manpower, equipment, time, and cost than using people, which is the current practice. Secondly, in disaster and fire monitoring, drones can analyze and identify disasters and fire sites in real time. Therefore, it was confirmed that the use of drones is helpful in securing the safety of firefighters and identifying a disaster site. Third, research in logistics shows that drones can secure the so-called golden time in emergency situations by delivering rescue and relief supplies, emergency medicine, and blood in short order. In a rapidly changing disaster environment, and considering aging in firefighters, this study is meaningful in that it promotes drone utilization in the firefighting field by investigating basic data on drone utilization plans.

Assessment of Fire Risk Rating for Wood Species in Fire Event (화재 발생 시 목재 수종의 화재위험성 등급 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.423-430
    • /
    • 2021
  • In order to evaluate the fire risk and fire risk rating of wood for construction materials, this study focused on fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) according to Chung's equations-III and -IV. Western red cedar, needle fir, ash, and maple were used as the specimens. The fire characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment on the specimen. The FPI-III measured after the combustion reaction was 0.86 to 12.77 based on polymethylmethacrylate (PMMA). The FGI-III was found to be 0.63 to 5.26 based on PMMA. The fire rating according to the FRI-IV, which is the fire rating index, was 0.05 to 6.12, and the western red cedar was 122.4 times higher than that of the maple. The fire risk rating according to the FRI-IV increased in the order of maple, ash, needle fir, PMMA and western red cedar. The CO peak concentration of all specimens was measured as 103 to 162 ppm, and it was 2.1 to 3.2 times higher than 50 ppm, the permissible exposure limits of the US occupational safety and health administration. Materials such as western red cedar, which have a low bulk density and contain a large amount of volatile organic substances, have a low FPI-III and a high FGI-III, so they have a high fire risk rating.

Investigation on CO Adsorption and Catalytic Oxidation of Commercial Impregnated Activated Carbons (상용 첨착활성탄의 일산화탄소 흡착성능 및 촉매산화반응 연구)

  • Ko, Sangwon;Kim, Dae Han;Kim, Young Dok;Park, Duckshin;Jeong, Wootae;Lee, Duck Hee;Lee, Jae-Young;Kwon, Soon-Bark
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.513-517
    • /
    • 2013
  • We investigated the properties of impregnated activated carbons, a commercial adsorbent for the individual protection equipment, and examined CO adsorption and oxidation to $CO_2$. The surface area, pore volume and pore size were measured for four commercial samples using Brunauer-Emmett-Teller/Barrett-Joyner-Halenda (BET/BJH), and atomic compositions of the sample surface were analyzed based on SEM/EDS and XPS. Impregnated activated carbons containing Mn and Cu for fire showed the catalytic CO oxidation to $CO_2$ with a high catalytic activity (up to 99% $CO_2$ yield), followed by the CO adsorption at an initial reaction time. On the other hand, C: for chemical biologial and radiological (CBR) samples, not including Mn, showed a lower CO conversion to $CO_2$ (up to 60% yield) compared to that of fire samples. It was also found that a heat-treated activated carbon has a higher removal capacity both for CO and $CO_2$ at room temperature than that of untreated carbon, which was probably due to the impurity removal in pores resulted in a detection-delay about 30 min.

Infant and Toddler Group Care at the Mother's Work Place (직장내 탁아프로그램 개발을 위한 기초연구 - 영·유아를 중심으로 -)

  • Zi, Heyon
    • Korean Journal of Child Studies
    • /
    • v.7 no.2
    • /
    • pp.1-15
    • /
    • 1986
  • Korea is a rapidly industrializing nation. As a consequence, more mothers are working outside the home. This trend is likely to continue into the future and raises the problem of infant-toddler care during the mother's working hours. Considering that Korea is making such rapid economic advances, quality care for children of working mothers Is not only desirable but affordable as well. Variety in options for child care is recommended by Beck (1982). Some of the alternatives in child care have been discussed elsewhere (KWDI, 1984). This paper, thus, concentrated on center-based, worksite child care. Because the human environment is the most important aspect of the center, qualified staff and a low ratio of children per staff member is Vital. Philosophy of program and its actualization ensures that the children have a worthwhile experience at the center. The physical plant houses the center and includes provision for space, materials, and equipment for staff and child use in carrying out the program. Adequate health protection is a critical factor in infant-toddler group care programs.

  • PDF

Evaluation of Smoke Risk and Smoke Risk Rating for Combustible Substances from Fire (화재로부터 연소성 물질에 대한 연기위험성 및 연기위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui;You, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.197-204
    • /
    • 2021
  • This study investigated the smoke risk assessment of woods and plastics for construction materials, focusing on the smoke performance index-V (SPI-V), smoke growth index-V (SGI-V), and smoke risk index-VI (SRI-VI) according to a newly designed methodology. Spruce, Lauan, polymethylmethacrylate (PMMA), and polycarbonate (PC) were used for test pieces. Smoke characteristics of the materials were measured using a cone calorimeter (ISO 5660-1) equipment. The smoke performance index-V calculated after the combustion reaction was found to be 1.0 to 3.4 based on PMMA. Smoke risk by smoke performance index-V was increased in the order of PC, Spruce, Lauan and PMMA. Lauan and PMMA showed similar values. The smoke growth index-V was found to be 1.0 to 9.2 based on PMMA. Smoke risk by smoke growth index-V increased in the order of PMMA, PC, Spruce, and Lauan. COpeak production rates of all specimens were measured between 0.0021 to 0.0067 g/s. In conclusion, materials with a low smoke performance index-V and a high smoke growth index-V cause a high smoke risk from fire. Therefore, it is understood that the smoke risk from fire is high. It is collectively summarized by the smoke risk index-VI.