• Title/Summary/Keyword: Protection measure

Search Result 598, Processing Time 0.033 seconds

Environmental Radiation Protection in Medical Institutions

  • Han, Eun-Ok;Dong, Kyung-Rae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.91-95
    • /
    • 2010
  • The study aimed to measure the levels of radiation protection for radiologists in medical institutions in three environmental categories (physical, administrative and social) and to establish a data base which can be used to increase awareness of environmental radiation protection in medical institutions within Korea. The study surveyed 10% of radiologists working in radiology departments in medical institutions which are supervised by the National Dose Registry overseen by the Korean Food and Drug Administration(KFDA). This study found that the level of environmental radiation protection was higher in the capital area and in larger hospitals. On the other hand, the study shows environmental radiation protection was lower in the Youngnam area and in clinics. Results from the questionnaires indicate the level of environmental radiation protection was higher when radiologists were given an individual dosimeter but lowest when the radiation protection apron quality test was conducted. Environmental radiation protection is an important factor for radiologists to conduct activities in a safe and protected environment. However, this study shows there are differences in the level of environmental radiation protection in medical institutions and location within Korea. In particular, the level of environmental radiation protection was lower in clinics, appropriate intervention strategies befitting these conditions are needed based on medical institution classification and location in order to improve the level of environmental protection.

Effect of Protection Motivation Factors on Behavioral Intention to Reduce Sodium Intake among University Students in Gyeongnam and Busan (보호동기요인이 나트륨 저감화 관련 행동 의도에 미치는 영향 - 경남·부산 지역 대학생을 중심으로 -)

  • Jang, Soo-Hyun;Yoon, Eunju
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.1
    • /
    • pp.104-114
    • /
    • 2016
  • In this study, we investigated protection motivation and behavioral intention to prevent serious illnesses related to excessive sodium intake among the university students in Gyeongnam and Busan. Within the protection motivation theory (PMT) framework, a survey questionnaire was developed to measure participants' perceptions on the severity of and the vulnerability to the threat of serious diseases due to the high sodium intake as well as the effectiveness of preventive measures (response efficacy), and the ability to perform them (self-efficacy) along with their willingness to follow recommendations (behavioral intention). Data was collected in June 2015. Study participants were divided into either low (n=117) or high (n=177) sodium intake behavior groups based on their current behaviors. Exploratory factor analysis was performed to measure construct validity and Cronbach's alpha was calculated to check reliability of measurement items. The high sodium intake behavior group perceived higher vulnerability than the low sodium intake behavior group among four PMT factors. Differences of the other three factors were not significant between the two groups. The results of hierarchical regression analysis indicated that self-efficacy and response efficacy affected behavioral intention of high sodium intake behavior among students. Hence, development of strategies to increase self-efficacy and response efficacy are strongly recommended.

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

Power system protection IED design using an embedded processor (임베디드 프로세서를 이용한 계통 보호 IED 설계)

  • Yoon, Ki-Don;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.711-713
    • /
    • 2004
  • In the past time, the protection relay did only a protection function. Currently, its upgraded device i.e. IED(Intelligent Electric Device) has been designed to protect, control, and monitor the whole power system automatically. Also the device is desired to successfully measure important elements of the power system. This paper considers design method of a digital protection IED with a function of measuring various elements and a communication function. The protection IED is composed of the specific function modules that are signal process module, communication module, input/output module and main control module. A signal process module use a DSP processor for analysis of input signal. Main control module use a embedded processor, Xscale, that has an ARM Core. The communication protocol uses IEC61850 protocol that becomes standard in the future. The protection IED is able to process mass information with high-performance processor. As each function module is designed individually, the reliability of the device can be enhanced.

  • PDF

Evaluation of the Impacts of SPD Connecting Lead Lengths and SPD Protection Distance to the Apparatus in Apartments (공동주택에서 SPD의 리드선 길이 및 보호거리에 대한 영향 평가)

  • Lee, Ki-Hong;Kang, Moo-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.94-101
    • /
    • 2011
  • The proper installation of SPD and the evaluation of the SPD protection distance are basic steps for the effective protection measures of apparatus against surges within a structure. A novel method for installing SPD on the conventional distribution board without any modification was proposed and it's effectiveness was evaluated by experiments. Also, the transient overvoltage occurred across the power line from the SPD to the load was simulated with EMTP software to see how different the protection distances affecting the magnitude of the transient overvoltage. As evaluated, the effective protection method of apparatus against surges, coordinated SPD protection system is suggested as a proper measure to protect within the apartment.

Realization of Protection IED for Distributed Power System (분산 전원 계통 연계용 보호 IED의 설계 및 구현)

  • Han, Chul-Wan;Oh, Sung-Nam;Kim, Kab-Il;Son, Young-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.517-519
    • /
    • 2005
  • In this paper, we consider a digital protection IED(Intelligent Electric Device) for a distributed power system. The IED can measure various elements for protection and communicate with another devices through network. The protection IED is composed of specific function modules: signal process module which converts analog signal from PT and CT handle algorithm to digital one; communication module for connection with another IEDs; input/output module for user-interfaces. A general purpose DSP board with TMS320C2812 is used in the IED. In order to verify the proposed IED, experimental researches with the power system simulator DOBLE has been carried out for a phase earth fault. The results show an under-voltage relaying algorithm has been realized sucessfully in the hardware system.

  • PDF

Critical Design Issues on the Cathodic Protection Systems of Ships

  • Lee, Ho Il;Lee, Chul Hwan;Jung, Mong Kyu;Baek, Kwang Ki
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.90-95
    • /
    • 2007
  • Cathodic protection technology has been widely used on ship's outer hull and inner side of ballast water tanks as a supplementary corrosion protection measure in combination with protective organic coatings. Impressed current cathodic protection system is typically opted for the ship's hull and, sacrificial anode system, for ballast water tanks. The anticipation and interest in cathodic protection system for ships has been surprisingly low-eyed to date in comparison with protective coatings. Computational analysis for the verification of cathodic protection design has been tried sometimes for offshore marine structures, however, in commercial shipbuilding section, decades old design practice is still applied, and no systematic or analytical verification work has been done for that. In this respect, over-rotection from un-erified initial design protocol has been also concerned by several experts. Especially, it was frequently reported in sacrificial anode system that even after full design life time, anode was remaining nearly intact. Another issue for impressed current system, for example, is that the anode shield area design for ship's outer hull should be compromised with actual application situation, because the state-of-the-art design equation is quite impractical from the applicator's stand. Besides that, in this study, some other critical design issues for sacrificial anode and impressed current cathodic protection system were discussed.

Experimental Research for Design of Distributed Power System Protection IED (분산 전원 계통 연계용 보호 IED 설계를 위한 실험 연구)

  • Han, Chul-Wan;Oh, Sung-Nam;Yoon, Ki-Don;Kim, Kab-Il;Son, Young-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.90-92
    • /
    • 2005
  • In this paper, we design a digital protection IED(Intelligent Electric Device) for a distributed power system in connection with power grid. The device can measure various elements for protection and communicate with another devices through network. The protection IED is composed of specific function modules: signal process module which converts analog signal from PT and CT handle algorithm to digital one; communication module for connection with another IEDs; input/output module for user-interfaces; main control module for control the whole modules. A general purpose DSP board with TMS320C2812 is used in the IED. Experiments with the power system simulator DOBLE have been made to verily the proposed hardware system.

  • PDF

A Research on Institution's Countermeasure for Personal Information Protection Act Based on the Examples of Performing the Privacy Impact Assessment (개인정보 영향평가 수행 사례에 기반한 기관의 개인정보보호법 대응방안에 관한 연구)

  • Cho, Sung Kyu;Jun, Moon Seog
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.1
    • /
    • pp.89-98
    • /
    • 2012
  • According to the enforcement of Personal Information Protection Act as of September 2011, the laws and regulations for the protection of personal information that were applied only to the certain sectors such as information & communication network, financial institutions, public sector etc. for the time being has been expanded to apply to all public and private sectors to process personal information. In particular, because the public institutions are obliged to be mandatorily conducted of the Privacy Impact Assessment, it will be enforced in earnest for each agency's informationization business that handles personal information. In this paper, I examine the most derived vulnerability and set up the improvement measure to supplement it with the examples of 10 of all the institutions conducting the Privacy Impact Assessment in the year 2011. And, I suggest the measures to be prepared by the institutions to observe the Personal Information Protection Act.

A Probabilistic Approach to the Protection Capability Evaluation of Distance Relay in Transmission Systems

  • Zhang, Wen-Hao;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.407-414
    • /
    • 2010
  • This paper proposes a probability measure for the evaluation of relay performance from two aspects, namely, correct trip and no-unwanted trip. They are developed based on the relationship between relay settings and relay measurements, which follow a Gaussian probability model. The proposed method based on strict mathematical derivation is applied to protection capability evaluation of distance relays under various settings. Considering the specific attributes of each protection zone, the optimal settings are also determined accordingly. The protection capability could demonstrate clearly the relay performance under various settings and the optimal settings could provide good references for engineering applications.