• Title/Summary/Keyword: Protection facility

Search Result 406, Processing Time 0.021 seconds

Spatial Configuration Analysis of the Elderly Care Facilities Based on Visibility - Visibility Analysis and Agent-Based Simulation Using Space Syntax - (가시성에 기반한 노인요양시설의 공간계획에 관한 분석 - 공간구문론을 활용한 가시성 분석과 에이전트 시뮬레이션을 중심으로 -)

  • Lee, Jisun;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.14-23
    • /
    • 2018
  • The spatial planning of the elderly care facility plans is analyzed using space syntax in terms of encouraging the social interaction of the residents in this study. First, through the visibility graph analysis, openness and accessibility of space is analysed. Second, the walking behavior of residents through agent analysis model is simulated. Third, the space planning methods for the elderly care facilities are proposed based on the results. The results are as follows. According to the visibility graph analysis, the main corridor has high visual openness and high accessibility. The visual openness and accessibility of the unit living room, where social interaction among residents is possible in each unit, is low. Space planning is needed to increase direct protection and observation of employees to the unit living room. The location of the nurse station that manages the entire floor needs to be located where the openness and accessibility is most high. The nursing station should have a high degree of connectivity to the entire space, so that any accidents can be managed and contact is accessible. Through the agent simulation the flow from the center to each unit space is highest in the corridor space and the inflow to the private rooms and the living room are similar. Therefore, it is necessary to plan the accessibility of the unit living room more for the natural inflow of residents.

A Study on the behavior of the Elderly and the optimum scale of the Necessary space in Daycare Center (주간보호센터의 이용자 행동과 소요공간의 적정규모에 관한 연구)

  • Kil, Jong-Won;So, Kab-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.6
    • /
    • pp.152-160
    • /
    • 2008
  • The Cases of advanced nations which have advanced welfare policy, they have headed for the deinstitutionalization and the protection of the local society. So they have expanded and improved the various policies and welfare facilities to be able to keep daily life on the base of local area. Many problems have been caused by rising the average life span of the elderly in Korea now. Under the tendency, there have been many alternative proposals to solve the problems. One of those proposals, the deinstitutionalization theory that is rated the ideal way, is the community-based care than the care in facilities for the elderly. It shows that the most ideal facility for the care is Daycare center and that it matters the system of spatial construction and standard of the facilities. Under the undetailed Korean standard of facility design, it is very important that system of spatial construction to correspond to the needs of the users and standard of the facilities are prepared from the point of view of the standard design of the domestic facilities for the elderly. The study of the book grasps the regional present situation of the domestic Daycare center and surveys the tendency of the stay and features of occupation of the user there through some case, and aims to have a thorough grip of the spatial scale by the user's behavior. It is to utilize for a proposal for preparation of the space scale, and an institution standard corresponding to user's needs in a Daycare center.

A Study on Characteristics of Building, Outdoor Playground & Equipment in Child Care Center (어린이집 건물, 실외놀이터 및 설비 특성에 관한 실태조사)

  • Byun, Hea-Ryung;Choi, Mock-Wha;So, Kab-Soo
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.9-18
    • /
    • 2013
  • Recently, interest and social expectation for children's environment are on the rise. The needs for construction of safe and pleasant child care environment has bees agreed with. Especially, as the number of children who are wanted to go center jumped with additional support the government for child care business, centers have also seen a boost. But as number of child care centers increases rapidly in short period, the quality of centers is more inferior to before. and the space and facility level of many centers don't reach in legal minimum standard. In addition to, when child care centers are reviewed, it tend to be judged by one standard without considering connection with sense of values about child care or philosophy, child's traits, surrounding environment etc. Therefore, it is important to construct environment that can consider children's physical development and behavioral characteristic as well as basic element such thing as protection and support activity for current child care centers. This study presupposes that physical environment of child care centers makes important effect on teacher's motion and child's development, then it is to investigate it's characteristics in physically space, facilities, outdoor playground. And It is to identify space and accommodations, outdoors facilities which can support activity smoothly inside and outside. As a result, it is try to offer appliable basic information about the child-friendly environment of child care centers.

Building Control Box Attached Monitor based Color Grid Recognition Methods for User Access Authentication

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Khudaybergenov, Timur;Kim, Min Soo;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • The secure access the lighting, Heating, ventilation, and air conditioning (HVAC), fire safety, and security control boxes of building facilities is the primary objective of future smart buildings. This paper proposes an authorized user access to the electrical, lighting, fire safety, and security control boxes in the smart building, by using color grid coded optical camera communication (OCC) with face recognition Technologies. The existing CCTV subsystem can be used as the face recognition security subsystem for the proposed approach. At the same time a smart device attached camera can used as an OCC receiver of color grid code for user access authentication data sent by the control boxes to proceed authorization. This proposed approach allows increasing an authorization control reliability and highly secured authentication on accessing building facility infrastructure. The result of color grid code sequence received by the unauthorized person and his face identification allows getting good results in security and gaining effectiveness of accessing building facility infrastructure. The proposed concept uses the encoded user access authentication information through control box monitor and the smart device application which detect and decode the color grid coded informations combinations and then send user through the smart building network to building management system for authentication verification in combination with the facial features that gives a high protection level. The proposed concept is implemented on testbed model and experiment results verified for the secured user authentication in real-time.

Family Resilience in Divorced Female Single-Parent Families : In Case of Residents in the Institutional Facility for Female Single-Parent Families (이혼한 여성 한부모가족의 가족레질리언스(Family Resilience) 연구 : 모자보호시설 입소자를 중심으로)

  • Kim, Kyung-Soon;Lee, Mi-Sook
    • Journal of Families and Better Life
    • /
    • v.27 no.1
    • /
    • pp.89-105
    • /
    • 2009
  • A family resilience approach aims to identify and fortify key interactional processes that enable families to withstand and rebound from disruptive life challenges. Walsh(1998) described family belief systems, organizational patterns, and communication processes as the three main keys of family resilience. The purpose of this study was to identify the three key factors of family resilience in case of divorced female single-parent families in Korea. The study participants were seven divorced mothers who were living in the institutional facility for female single-parent families. Using a qualitative approach, in-depth interviews were audiotaped and transcribed verbatim for analysis. The study findings were as follows. First, the participants showed positive thinking rather than fear about the adversity induced by the divorce. They also showed the senses of competence, control, and self-esteem. However, the senses of transcendence and spirituality were barely evident. Second, emotional and economic supports from parents, brothers and sisters, and community networks (i.e., mother-child protection institution, healthy family support center) enhanced the family resilience of the participants. Third, the participants showed clear communication, open emotional expression, and shared decision making. This study suggests that more counseling services and parent education be provided by healthy family support center and institutional facilities as important family resilience factors for divorced female single-parent families who are below the poverty line.

A Study on the Improvement of Methodologies for Establishing a Vulnerability Classification of Chemical Terrorism in Public Facilities (다중이용시설 화학테러 취약등급설정 방법론 개선에 대한 연구)

  • Joo, Sun Ho;Kim, Si-Kuk;Hong, Sungchul
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.89-102
    • /
    • 2020
  • Chemical terrorism using toxic and flammable gases, which could be fatal to the health of the human body, poses a serious threat to the security of most advanced countries, as well as those that are suffering from local disputes, due to the asymmetric information that exists between terrorist actors and victims. The countermeasures against chemical terrorism can be roughly divided into three stages: prevention, response, and probation. The critical factors for each professional response agency, and the personnel that determine the degree and range of chemical terrorism damage, are performing missions successfully in the process of the prevention and the response stage against chemical terrorism. To do this, conducting objective and systematical assessments on facilities that could potentially be the subject of chemical terrorism is more important than anything. In this study, we compared the existing domestic and foreign vulnerable classification systems for chemical terrorism, reviewed the current direction of improvement in domestic classification systems, and suggested more scientific and systematic methodologies through the vulnerability assessment on an actual public facility sample.

A Study for Protocol for Heterogeneous Interface in Sensor Networks within Water Restore Facilities (수질복원시설물 내 센서 네트워크 이기종간 인터페이스용 프로토콜에 관한 연구)

  • Kim, Chan;Shin, Jaekwon;Cha, Jaesang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.255-260
    • /
    • 2012
  • Currently, the management system of wastewater treatment facility has magnified due to the stringent regulations for the protection of the environment. However, wastewater treatment system is insufficient in wastewater quality monitoring technology in specialized. Above all it aim one-to-one data transmission instead of one-to-n data transmission through sensor and network. And then, it lack compatibility toward communication system between different. Mainly it has observed detecting system of manual system. In this paper, we studied protocol technology about efficient data transmission between sensor and integration interface of water quality detecting interface for automated sensor network integration interface in water restoration facility. Therefore, we proved the possibility of efficient data transmission from communication system of different type through monitoring implementation of sensor network integration interface.

Using AHP to Develop a Rehabilitation Room Management Model for Fire Officers at Disaster Sites (재난현장 소방공무원의 회복실 운영모델 개발)

  • Yim, Dong-Kyun;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.115-124
    • /
    • 2020
  • The purpose of this study was to provide an operational model of the rehabilitation room for fire officers at disaster sites to improve the safety and resilience of fire officers. Therefore, we analyzed the operation related elements of the rehabilitation room-such as overseas rehabilitation room operation cases and previous studies- and managed different factors including, but not limited to, management and human resources, equipment and facility, and accessibility and convenience factors; afterward, the relative importance and importance of sub-layers in each field were measured. The priority of items for the operation of the rehabilitation room for fire officers at disaster sites was elucidated; after expert analysis, it was found that human resources were the most crucial factor. Finally, it was found that, in descending order, accessibility and convenience, administrative, equipment, and facility factors were also essential. Based on this, we proposed a rehabilitation room operation guideline for disaster sites.

A Study on the Institutional Improvement Plan through Consumer Survey of Financial Support Programs for Industrial Accident Prevention (산업재해 예방을 위한 재정지원사업의 수요자 설문조사를 통한 제도적 개선방안 연구)

  • Bae, Dong Chul
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.62-71
    • /
    • 2018
  • The purpose of this study is to conduct surveys on demanders using financial aid projects to prevent industrial accidents and to improve them. It is divided into clean business and loan support business through the structured questionnaire. In the case of clean business, the following results were obtained. Most of the applications were received within three months after application. The most important factor considered by the consumer is the amount of support, which is considered to consider the substantial improvement as follows.The expectation for the reduction of industrial accidents after the project was 96.1% and compared to before and after the actual business, it showed a 46.8% decrease from the previous year. In addition, the cost decreased by 21.8%, the facility utilization rate increased by 24.4%, the sales increased by 15.9%, and the average number of workers increased by 6.0. As for the sustainability of the business, 86.6% of the respondents said that they should continue to do so. The following results were obtained in the case of loan support projects. Industrial accidents decreased by 45.2% from the previous year. Costs decreased by 19.4%, facility utilization rose by 26.7%, sales increased by 14.9%, and the number of workers increased by an average of 2.8. In the case of suppliers, prevention of industrial accidents at the business sites participating in the clean business was the highest factor (67.0%). 89% of respondents were aware of the disposal criteria for ineligible suppliers. 50.6% of the respondents answered that it is appropriate to maintain the current level, and 39.4% of respondents answered that they should strengthen. The prices for the support items were more than 15% higher than the market prices.

Study on the Introduction of EMC Engineering System in Korea (전자파 엔지니어링 제도 도입 방안에 관한 연구)

  • Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.942-949
    • /
    • 2012
  • In order to ensure the safety of the large-scale public facilities, the analysis of EMC(ElectroMagnetic Compatibility) of electronic systems included in the facilities is very necessary. The reason is that the system-level EMC of the facility could be not guaranteed, even if individual equipments included in the facility are satisfied with their EMC requirements. As a result, the system-level evaluation and analysis of EMC should be carried out in order to establish the reliable operations of safety and mission-critical electronic systems. This paper analyze the relevant legal systems of domestic and other countries, and furthermore case studies of system-level EMC approaches were analyzed in the specific applications of electric railways, building, automobile, petroleum refinery systems. And the introduction of related systems in Korea is proposed, and main parts and problems to be looked at each proposed measures are discussed. The results are expected to be utilized in the introduction of the system-level EMC engineering, and contributed in national security and the protection of people's life, body and their properties.