• 제목/요약/키워드: Protection facility

검색결과 406건 처리시간 0.025초

공장 및 제조장 난개발 방지를 위한 지구제 적용방안에 관한 연구 -화성시를 사례로- (A Study on the Applied Zoning System for the Preventing Reckless Developments due to Industrial Facility Construction -A Case Study on Hwasung-)

  • 김철홍;이원영;최형석
    • 한국환경복원기술학회지
    • /
    • 제5권5호
    • /
    • pp.45-57
    • /
    • 2002
  • This study aims to suggest the applied zoning system for preventing reckless developments due to individual industrial facility construction. According to the types of reckless developments which has been found in Hwasung, the applied zoning system including 4 kinds of districts can be proposed. Collective Inducement District can be designated to where many industrial facilities have already existed with poor infrastructure, and the other districts such as Residential Area Protection District, Reservoir-Around and Agricultural Area Protection District, or Landscape Protection District may be designated to the sites where reckless developments due to individual industrial facility construction may happen. This zoning system seems to be used as a guideline of new zoning of revised NLUPL(National Land Use and Plan Law) after the execution.

STUDY ON X-RAYS AND NEUTRONS LEAKED FROM A 45 MeV ELECTRON LINAC FACILITY

  • Sawamura, Sadashi;Kitaichi, Masatoshi;Nojiri, Ichiro;Yamada, Takuma;Kaneko, Junichi;Sawamura, Teruko
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.133-137
    • /
    • 2001
  • Spatial and time distributions of x-rays and neutrons from Hokkaido University 45 MeV electron linac facility were measured and compared with the calculation. In the calculation, x-rays in a Pb-target were evaluated using the EGS-code. The x-rays and the neutrons from the target to the facility building boundary and skyshine process outside the facility building were simulated with the EGS and the MCNP respectively.

  • PDF

주요 정보통신기반시설의 평가컨설팅 방법론에 대한 연구 (A Study on the Evaluation Consulting Methodology of Important Information Communication Base Facility)

  • 이영로;조재완
    • 디지털융복합연구
    • /
    • 제5권1호
    • /
    • pp.55-68
    • /
    • 2007
  • It soaks but 2001 July information communication base step law enforcement and the Enforcement Ordinance are published to follow, in order to support the establishment of evaluation and protective measure in order the vulnerability analysis against the facility of the agency which manages an important information communication base hour opinion to designate information protection specialty enterprise. As information protection specialty enterprise being revealed evacuation laboratory back 12 enterprises from information communication department become designation as the consulting enterprise and they do an enterprise activity actively. It follows in diffusion of the IT and information reconciliation level the other side where our country belongs in the world-wide first group, the research against the disfunction plan of preparation comparison the fact that law it is come negligently all actuality. The network as it will give management coat fatal effect even at obstacle occurrence hour of instant for of case and IT facility of the cyber transactions which leads, in the future there to be to corporate management, there is a possibility the stable civil official of information Facilities for communications very seeing in the portion which is important. Present condition and important propulsion contents of information communication base step law enforcement after, against a vulnerability analysis of information protection relation field and evaluation consulting methodological application situation to sleep it researches from the dissertation which it sees consequently and it does.

  • PDF

VIPEX를 이용한 가상 원자력시설의 핵심구역 파악 분석 (Vital Area Identification Analysis of A Hypothetical Nuclear Facility Using VIPEX)

  • 이윤환;정우식;이진홍
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.87-95
    • /
    • 2011
  • The urgent VAI(Vital Area Identification) method development is required since 'The Act of Physical Protection and Radiological Emergency' that is established in 2003 requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The KAERI(Korea Atomic Energy Research Institute) has developed the VAI methodology and VAI software called as VIPEX(Vital area Identification Package EXpert) for identifying the vital areas. This study is to demonstrate the applicability of KAERI's VAI methodology to a hypothetical facility, and to identify the importance of information of cable and piping runs when identifying the vital areas. It is necessarily needed to consider cable and piping runs to determine the accurate and realistic TEPS(Top Event Prevention Set). If the information of cable and piping runs of a nuclear power plant is not considered when determining the TEPSs, it is absolutely impossible to acquire the complete TEPSs, and the results could be distorted by missing it. The VIPEX and FTREX(Fault Tree Reliability Evaluation eXpert) properly calculate MCSs and TEPSs using the fault tree model, and provide the most cost-effective method to save the VAI and physical protection costs.

부산·경남 일부지역의 치과방사선 인식도와 수행도에 따른 치과방사선 방어행위 (The awareness and performance towards the dental radiation protection behaviors in Busan and Gyeongnam)

  • 나현희;진혜정;이민경
    • 한국치위생학회지
    • /
    • 제14권5호
    • /
    • pp.673-680
    • /
    • 2014
  • Objectives : The purpose of this study is to investigate the awareness and performance towards the dental radiation protection behaviors in dental institutions in Busan and Gyeongnam. Methods : Two hundred and one dental medical institutions in Busan and Gyeongnam participated in the survey from March 10 to April 4, 2014. The data were analyzed using SPSS 19.0 for ${\chi}^2$ test, t-test, ANOVA, and multiple regression analysis. Results : There were significant differences in the awareness and performance towards the radiation protection behaviors according to age, monthly income, and type of hospital(p<0.05). Protective equipment influenced on the awareness and performance of dental staff and patients(p<0.001). The important variables on dental radiation protection included protection facility and education of protective equipment. It is found the variable to affect the performance of dental radiation protection was protection facility, wearing of protective device staff and patients, education on RSM. Conclusions : These results can provide the basic data for the effective dental radiation safety management and improvement for the dental institutions.

350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구 (A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line)

  • 이학표;서기범;박재영
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

방화설비계통 설계용 전산소프트웨어 개발에 관한 연구 (A Study on the Development of Computer Software for the Design of Fire Protection System)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.275-284
    • /
    • 1998
  • Standard on the carbon dioxide extinguishing system was prepared by the committed of the national fire protection assocition(NFPA)in USA on 1980. And this code is also applied to the design of a marine fire extinguishing system The most important problem in design is the uniform discharge of $CO_2$ through each nozzle from the high pressure $CO_2$ storage facility. The purpose of this paper is to develop the computer software to design the marine fire protection piping system. By solving the continuity equation energy equation and Bernoulli's equation simulataneously the flowrate in branch pipelines and discharge nozzles can be calculated.

  • PDF

지뢰제거복의 착용실태에 관한 기초조사연구 (A Research on The Actual Condition of Demining Suit Wearing)

  • 최혜선;손부현
    • 한국의류학회지
    • /
    • 제25권2호
    • /
    • pp.259-267
    • /
    • 2001
  • The purpose of this study is to find out the actual condition of demining suit wearing for developing a new demining suit. The existing clothes fro detecting or demining work are lack of security, activity, and comfort. Especially, the lack of protection on the limbs and the head, and the lack of protection of its own fabrics themselves are problems in security. Developing new demining suit should consider security, activity, and facility for putting on and off the clothes with comfort. And first of all, protection from the fragments should be considered. For the improvement of the activity, flexibility, lightness, and simplicity with suitable size with minimum bulk should be considered. In adjustment, the facility is more important than the strength and the newly developed material for protection need lightness, too.

  • PDF

사회복지관 피난모델링을 통한 시나리오 개발의 필요성 (The Need for Developiong Scenarios through Social Welfare Facility Evacuation Modeling)

  • 김진하;김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제25권2호
    • /
    • pp.29-38
    • /
    • 2023
  • Social welfare facilities are used by a wide range of local residents, including vulnerable populations such as the elderly, children, and people with disabilities. During emergencies like fires, confusion can arise as these individuals try to evacuate. Evacuation simulation results have shown that utilizing evacuation systems based on specific evacuation scenarios can significantly decrease the time required for evacuation compared to general evacuation procedures. By anticipating potential fires based on changes in social and facility environments, appropriate evacuation scenarios can be developed and applied to evacuation systems, thus contributing to the safety and security of individuals during emergencies. In conclusion, for social welfare facilities that serve a large number of people, it is necessary to expand the focus on performance-based design depending on the size of the facility, and to continuously develop and train for appropriate evacuation scenarios that align with changing facility environments.