• Title/Summary/Keyword: Protection Rate

Search Result 1,733, Processing Time 0.027 seconds

Dyeing Property and Functionality of Silk Fabrics Dyed with Rhododedron brachycarpum Extracts (만병초 추출물에 의한 견직물의 염색성 및 기능성)

  • Kim, Sangyool
    • Journal of Fashion Business
    • /
    • v.23 no.3
    • /
    • pp.23-34
    • /
    • 2019
  • The aim of this study is to explore the possibility utilizing Rhododedron brachycarpum as a new natural dye resource. It was dyed in silk fabric according to different dyeing conditions such as dye concentration, dye bath temperature, dyeing time and dye bath pH. The effect of the mordanting conditions were estimated as dyeability and color changes. Additionally, the colorfastness, antibacterial property, ultraviolet protection properties of the dyed and mordanted silk fabrics were examined. The water-soluble dye of Rhododedron brachycarpum extracted with distilled water was expressed as Yellow Red color. The dye-abilities of silk generally increased depending on the increasing values of dye concentration, dye bath temperature and dyeing duration. The highest K/S values were obtained at a dye concentration of 100% (v/v), a dye bath temperature of $90^{\circ}C$, a dyeing duration 120 minutes and a dyeing of pH 2. The light fastness of dyed and Cu mordanted silk fabrics were found to be 4 grade while Al, Fe mordanted silk fabrics were found to be 2~3 grade. The dry cleaning and rubbing fastness were excellent or good. The fade of washing fastness was not good, however, the stain of washing fastness was excellent. The dyed and Al, Cu mordanted silk fabrics indicated 99.9% reduction rate. The dyed and the mordanted fabrics showed very good ultraviolet protection factors.

A Study on The Natural Dyeing of Crataegi fructus Extracts (산사 추출물을 이용한 천연염색 연구)

  • Kim, Sangyool
    • Journal of Fashion Business
    • /
    • v.23 no.4
    • /
    • pp.100-111
    • /
    • 2019
  • In this study, the dyeing properties and functionalities of Crataegi fructus extract were investigated for the purpose of application to new natural dye resources. The effects of dyeing conditions(concentration of dye, dye bath temperature, dyeing duration and dye bath pH) and mordanting on dye uptake and color changes were also examined. The study also estimated the colorfastness, antibacterial properties, and ultraviolet protection properties of the dyed and mordanted silk fabrics. The dye uptake increased in tandem with the dye concentration and dye bath temperature. The highest K/S values were obtained at the following conditions: a dye concentration of 100%(v/v), a dyeing period of 60 minutes, a dye bath temperature of $90^{\circ}C$, and a dyeing pH of 3. The colorfastness of the material when dry cleaned or rubbed ranged from good to excellent and fastness to light was rated at grade 2-3. The change in the color grade when exposed to washing was not good; however, the stain of washing fastness was good at a range of 4-5. In regards to the functional property aspects, the dyed and mordanted fabrics exhibited excellent results with a 99.9% reduction rate, and excellent ultraviolet protection factors.

Review about the Lightning Protection System for Ground Facilities of Anti-aircraft Weapons System (뇌 보호시스템의 대공무기체계 지상시설 적용에 대한 고찰)

  • Jung, Kyoungwook;Shim, Donghyouk;Son, Donghyeop
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.339-347
    • /
    • 2021
  • Recently, the incidence of lightning in Korea has been increasing more and more. The damage caused by lightning is also getting worse. Lightning protection system is a prerequisite, not a sufficient condition. Considering the characteristics of lightning, there is a high frequency of lightning strikes in highlands. So, high grades of LPS should be applied to ground facilities of anti-aircraft weapons systems. 4-Level LPS was applied on groung facilities of anti-aircraft weapons system based on lightning incidence rate in past. There are some possibilities of damage from lightning in anti-aircraft weapons system. So, we have to readjust the LPS level with grounding, lightning rods and surge protect device based on lightning incidence rate in now days. Propose 2-level LPS and design with lightning rods, surge protector, separated grounding in this paper.

Effectiveness of Active Hood and Pedestrian Protection Airbag Based on Real Vehicle Impact Test (실차평가시험을 기반으로 한 액티브 후드 및 보행자 보호 에어백 효과)

  • Yun, Yong-Won;Park, Gyung-Jin;Kim, Tai-Kyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.36-45
    • /
    • 2014
  • Pedestrian to vehicle traffic accidents show a very high mortality rate compared to the frequency of occurrence. In order to improve the pedestrian protection performance of the vehicle, the korean government added a "pedestrian safety" entry from the year 2007. The performance for pedestrian protection of current vehicles gradually improved compared to the past, but it is still insufficient. It was found that the pedestrian protection performance was very weak, such as the top of the bonnet, the A-pillar and under the front windshield. A application of an active hood and pedestrian protection airbags can be countermeasures for these weak points of pedestrian safety. The active hood and pedestrian protection airbags are designed and manufactured to apply to the top of the hood and to the bottom of the windshield. The manufactured system is equipped in a test vehicle and evaluated based on the Korea New Car Assessment Program(KNCAP) test procedures for the performance of pedestrian safety. As a result, the outstanding effect of pedestrian protection has been achieved by the active hood and the pedestrian protection airbag. The rates of pedestrian injury are reduced by 82.2% and 95.4%, respectively.

THE SHORT-TERM EFFECTS OF LOW-DOSE-RATE RADIATION ON EL4 LYMPHOMA CELL

  • Bong, Jin-Jong;Kang, Yu-Mi;Shin, Suk-Chul;Choi, Moo-Hyun;Choi, Seung-Jin;Lee, Kyung-Mi;Kim, Hee-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.56-62
    • /
    • 2012
  • To determine the biological effects of low-dose-rate radiation ($^{137}Cs$, 2.95 mGy/h) on EL4 lymphoma cells during 24 h, we investigated the expression of genes related to apoptosis, cell cycle arrest, DNA repair, iron transport, and ribonucleotide reductase. EL4 cells were continuously exposed to low-dose-rate radiation (total dose: 70.8 mGy) for 24 h. We analyzed cell proliferation and apoptosis by trypan blue exclusion and flow cytometry, gene expression by real-time PCR, and protein levels with the apoptosis ELISA kit. Apoptosis increased in the Low-dose-rate irradiated cells, but cell number did not differ between non- (Non-IR) and Low-dose-rate irradiated (LDR-IR) cells. In concordance with apoptotic rate, the transcriptional activity of ATM, p53, p21, and Parp was upregulated in the LDR-IR cells. Similarly, Phospho-p53 (Ser15), cleaved caspase 3 (Asp175), and cleaved Parp (Asp214) expression was upregulated in the LDR-IR cells. No difference was observed in the mRNA expression of DNA repair-related genes (Msh2, Msh3, Wrn, Lig4, Neil3, ERCC8, and ERCC6) between Non-IR and LDR-IR cells. Interestingly, the mRNA of Trfc was upregulated in the LDR-IR cells. Therefore, we suggest that short-term Low-dose-rate radiation activates apoptosis in EL4 lymphoma cells.

Radiation Monitoring in the Residential Environment: Time Dependencies of Air Dose Rate and 137Cs Inventory

  • Yoshimura, Kazuya;Nakama, Shigeo;Fujiwara, Kenso
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.30-38
    • /
    • 2022
  • Background: Residential areas have some factors on the external exposure of residents, who usually spend a long time in these areas. Although various survey has been carried out by the government or the research institutions after the Fukushima Daiichi Nuclear Power Plant accident, the mechanism of radiocesium inventory in the terrestrial zone has not been cleared. To better evaluate the radiation environment, this study investigated the temporal changes in air dose rate and 137Cs inventories (Bq/m2) in residential areas and agricultural fields. Materials and Methods: Air dose rate and 137Cs inventories were investigated in residential areas located in an evacuation zone at 5-8 km from the Fukushima Daiichi Nuclear Power Plant. From December 2014 to September 2018, the air dose rate distribution was investigated through a walking survey (backpack survey), which was conducted by operators carrying a γ-ray detector on their backs. Additionally, from December 2014 to January 2021, the 137Cs inventories on paved and permeable grounds were also measured using a portable γ-ray detector. Results and Discussion: In the areas where decontamination was not performed, the air dose rate decreased faster in residential areas than in agricultural fields. Moreover, the 137Cs inventory on paved surfaces decreased with time owing to the horizontal wash-off, while the 137Cs inventory on permeable surfaces decreased dramatically owing to the decontamination activities. Conclusion: These findings suggest that the horizontal wash-off of 137Cs on paved surfaces facilitated the air dose rate decrease in residential areas to a greater extent compared with agricultural fields, in which the air dose rate decreased because of the vertical migration of 137Cs. Results of this study can explain the faster environmental restoration in a residential environment reported by previous studies.

An Analysis of Bed Change Characteristics by Bed Protection Work (바닥보호공 설치에 따른 하상변동 특성 분석)

  • Son, Ah Long;Kim, Byung Hyun;Moon, Bo Ram;Han, Kun Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.821-834
    • /
    • 2015
  • This study presents the analysis of flow and bed change characteristics considering bed protection work built on the immediate downstream of weir to protect river bed from scouring. The study area is 37km reach from Hyunpoong station to Masuwon station including Hapcheon- Changryoung multi-function weir in the Nakdong river. CCHE2D model is calibrated and validated for evaluating the flow and bed change characteristics during Typhoon Kompasu in 2010. Three simulation conditions are set up: Case 1 is a natural channel without installation of weir. Case 2 involves an installation of weir in the natural channel. Case 3 involves an installation of weir with bed protection in the natural channel. Flood frequency (50, 100 and 200yr) is applied to each scenario to analyze the effects of bed protection work. While the sediment rate is increased in the downstream of fixed gate and sluice-type gate, river bed scouring rate is increased in the downstream of lift-type gate in Case 2 comparing with the results of Case 1. The river bed scouring is not occurred in the immediate downstream of weir (~30m) due to the effect of bed protection, but larger amount of sediment is occurred in the downstream of weir (60m~) which the bed protection is not installed comparing with the results Case 1. Through the results of simulation considering bed protection work, this study would be helpful to expect bed change and operate the weir as well as manage.

Estimation of Corrosion Protection of Inhibitor for Concrete by Electrochemical Techniques (전기화학적 기법을 이용한 콘크리트용 방청제의 성능평가)

  • 문한영;김성수;김홍삼;안기용;안재우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.207-210
    • /
    • 1998
  • Recently it has become general to use the inhibitor with a view to protecting corrosion of rebars in concrete. So, it needs to study effect of protection and reasonable dosage of inhibitor to reduce corrosion of rebar in concrete containing chlorides. In this study, we estimate the corrosion rate of rebar in mortar by Tafel extrapolation method, one of electrochemical techniques, and the reasonable dosage of inhibitor for different chlorides environments.

  • PDF

Numerical Analysis Methods for Heat Flow in Fire Compartment (화재실의 열유동 해석을 위한 수치 해석 방법)

  • Kim, Gwang-Seon;Son, Bong-Se
    • Fire Protection Technology
    • /
    • s.16
    • /
    • pp.20-23
    • /
    • 1994
  • This article investigates the different numerical methods, which are widely used for purpose of simulating a fire compartment the particular numerical methods such as finite difference, finite element, control Volume, and finite analysis are discribed in order to understand basic concepts and their applications. The fire simulations using fferent methods for the different physical geometrics have been reported in many recent literatures The convergence rate, the accuracy, and the stability are no simply dependent upon the specific method, The study of popular nu-merical methods by being compared among those is therefore significant to understand the nu-merical simulation of fire compartment.

  • PDF

Precision analysis on the ISO 13784-1's Round Robin scenarios (ISO 13784-1 RRT 결과의 정밀도 분석)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.333-336
    • /
    • 2012
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equlity of distribution also analyzed on the point of statistical view based on ISO.

  • PDF