• 제목/요약/키워드: Protection Function

검색결과 1,145건 처리시간 0.024초

임베디드 프로세서를 이용한 계통 보호 IED 설계 (Power system protection IED design using an embedded processor)

  • 윤기돈;손영익;김갑일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.711-713
    • /
    • 2004
  • In the past time, the protection relay did only a protection function. Currently, its upgraded device i.e. IED(Intelligent Electric Device) has been designed to protect, control, and monitor the whole power system automatically. Also the device is desired to successfully measure important elements of the power system. This paper considers design method of a digital protection IED with a function of measuring various elements and a communication function. The protection IED is composed of the specific function modules that are signal process module, communication module, input/output module and main control module. A signal process module use a DSP processor for analysis of input signal. Main control module use a embedded processor, Xscale, that has an ARM Core. The communication protocol uses IEC61850 protocol that becomes standard in the future. The protection IED is able to process mass information with high-performance processor. As each function module is designed individually, the reliability of the device can be enhanced.

  • PDF

송전선로 보호용 디지털 지능형 거리계전기 (Digital Adaptive Distance Relay for Transmission Line Protection)

  • 정창호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.411-416
    • /
    • 2001
  • Distance relay is the most widely used in transmission line protection because it is applicable not only as main protection but also as back-up protection. However, the protection range of the distance relay is always fixed in the unchangeable operating range while the power system varies, and therefore the distance relay is the device that is the highly influenced by the power system changes. In this regard, this paper describes an approach to minimize the mal-operation of the distance relay due to the power system changes through changing protection range of the distance relay into optimal condition in response to the load variation and power system condition. Also mal-function of the distance repay in case of high resistance ground faults could be minimized through modeling the protection range into quadratic function.

  • PDF

발전기 보호용 다기능 IED 시제품 H/W 구현에 관한 연구 (A Study on Implementation of Multi-Function Prototype IED H/W for Generator Protection)

  • 김윤상;안태풍;박철원
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.74-80
    • /
    • 2013
  • Generator faults does not happen more often than the transmission and substation facility faults. However, impacts on the power system by generator faults are very large. In order to minimize the impact of generator faults, generator protection and control system with high reliability is required. Most of the generator relay in generator protection and control system of large power plant of Korea is operated by imports from abroad. Accordingly, in order to accumulate source technology and increase the import substitution effect, localization of multi-function generator protection IED is being developed. This paper deals with the implementation of a multi-function prototype IED H/W, which can be command and data exchange through communication for measuring, monitoring, protection and control. And the IED specification, various relay elements, measurement elements, communication functions, module function, and test system for the prototype IED H/W are described.

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

공공안전을 위한 국가기반체계 보호제도의 핵심기능연속성에 관한 연구 (A Study on the Continuity Essential Function of Critical Infrastructure Protection System for Public Safety)

  • 강희조
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권4호
    • /
    • pp.795-802
    • /
    • 2017
  • 자연재난 및 사회재난 등으로 인해 국가기반시설의 기능이 정지되어 국가기반체계가 마비된다면 국민의 생명 신체 및 재산피해는 물론 국가안보에 심각한 위협요인으로 작용할 수 있다. 본 논문에서는 국가기반체계 보호제도에 대한 국내외 동향을 살펴보고 국가운영연속성인 핵심기능연속성의 세부구성 요소인 필수기능, 승계 순서, 권한의 위임, 연속성 시설, 연속성 통신, 중요 기록 관리, 인적 자본, 테스트, 교육 및 훈련, 통제 및 지시 권한이양, 복원에 대하여 구체적으로 알아보고 국가기반 체계 보호계획 관련제도의 분석을 실시하여 구체적인 문제를 살펴보고 효율적인 국가기반체계 보호제도 개선안을 제시하였다.

스포츠 참여 동기에 따른 고기능성 스포츠웨어의 요구 및 구매의도 (Consumers' needs and purchase intention of high functional sportswear according to sport participation motivations)

  • 김용숙
    • 한국생활과학회지
    • /
    • 제22권1호
    • /
    • pp.141-155
    • /
    • 2013
  • The purpose of this study is to identify consumers' needs and purchase intention of high-functional sportswear according to sports participation motivations. Internet survey was done for data collection and the subjects were 300 consumers in their 20-39's who participated in sport activities at least once a week. Factors of sport participation motivations were ostentation, social interaction, self development, mental health, and physical health. Consumers were segmented into the motivation retard group, the multi-purpose pursuit group, the health pursuit group, and the extrinsic motivation pursuit group. And factors of consumers' needs for high-functional sportswear were practicality and comfort function, body protection and physical function, and skin protection and health function. The multi-purpose pursuit group showed strong needs for active and comfort, body protection and physical function, and skin protection and health function but the motivation retard group showed the lowest needs for high functional sportswear. Purchase experiences of high-functional sportswear, accomplishment, and duration period of sport activity affected positively on the purchase intention of high-functional sportswear.

Arm Short 보호 기능을 포함한 다기능 IGBT GATE DRIVER (Multi Function IGBT Gate Driver Including Arm Short Protection)

  • 이경복;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.202-209
    • /
    • 2000
  • This paper introduces the main function and protection method of IGBT gate driver that designed by KOROS. Recently, the applications of insulated gate bipolar transistors(IGBTs) have expanded widely, particularly in the area of railway converters. This driver is suitable for railway traction applications, so they are designed for circumstance of railway vehicle such as vibration. The input control power for this driver is supplied from battery charger of railway. it is no necessary an isolated power supply board or auxiliary power supply, with substantial savings in cost and space in railway applications. This gate driver can be used wide range of input voltage. So, performance of the driver has no relation with the battery voltage(70V∼110V). The protection methods of IGBT gate driver have many kind of ways, but this gate driver it designed to apply to converter for railway system, so this gate driver includes protection for arm short current and low control power voltage, etc. And the process of protection method and protection reference value are optimized by means of sufficient test with our own facilities.

  • PDF

Sequential Estimation with $\beta$-Protection of the Difference of Two Normal Means When an Imprecision Function Is Variable

  • Kim, Sung-Lai;Kim, Sung-Kyun
    • Journal of the Korean Statistical Society
    • /
    • 제31권3호
    • /
    • pp.379-389
    • /
    • 2002
  • For two normal distribution with unknown means and unknown variances, a sequential procedure for estimating the difference of two normal means which satisfies both the coverage probability condition and the $\beta$-protection is proposed under some smoothness of variable imprecision function, and the asymptotic normality of the proposed stopping time after some centering and scaling is given.

멀티 에이전트 시스템 (Multi-Agent System)을 이용한 배전계통의 적응 과전류보호 (Multi-Agent System having Adaptive Over Current Protection Function for Power Distribution Systems)

  • 장중구;이승재;임동진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.365-372
    • /
    • 2001
  • This paper presents a new protection concept to achieve the adaptive optimal function by introducing the multi-agent system technology. Making each relay an agent which consists of relay agent module and coordinator module, each agent works autonomously to improve protection capability by cooperating with other agents. It is applied to the overcurrent protection system of the industrial power system in order to show the feasibility of the proposed methodology.

  • PDF

전력조절분배기 저전압 컨버터 모듈의 고장 방지에 대한 연구 (Study on the Failure Protection Mechanism for the Low Voltage Converter Module of Power Control and Distribution Unit)

  • 박성우;박희성;장진백;장성수;이상곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.285-288
    • /
    • 2008
  • Even though many modular converters have several internal protection circuit blocks for various abnormal operation conditions, there are many failure cases on modular converters at real applications. In this paper, the control strategy for failure protection of converters with internal 'In-Hibit' function is investigated. As an example, for the MDl modular converters the in-hibit function application is realized and the test results shows that adopting in-hibit function while converter switching reduces the voltage and current stress. And the reduction of switching stress on converter will decrease failure rate on converters.

  • PDF