• 제목/요약/키워드: Protection Facilities

Search Result 844, Processing Time 0.027 seconds

Damage Evaluation for the Column of Underpass Considering the Collision of a Vehicle (차량의 충돌을 고려한 지하차도 기둥의 손상 평가)

  • Park, Jang Ho;Kim, Young Woong;Park, Jaegyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.169-176
    • /
    • 2015
  • The protection facilities against the collision of the vehicle should be considered in the design of the bridge by the regulations, but there is no regulation against the collision of the vehicle in the design of the column of underpass. Impact analysis for the column of underpass was performed in order to evaluate the damage of the structure by the collision of the vehicle. Impact analysis was performed according to the various parameters such as material properties of the structure and types and velocities of the vehicle. From the numerical results, the structural damage for the column of underpass by the collision of the vehicle was evaluated and considerations in the design for a column of underpass against the collision of the vehicle were examined.

A Study on the Funeral director's working Circumstances and Management Facilities associated Infection Disease on Funeral home (국내 안치실 및 염습실 종사자의 근무환경 및 질병관리시설현황에 대한 연구)

  • Hwang, Kyu-Sung;Chang, Man-Suck;Jin, Sang-Myoung;Kim, Jeong-Lae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • Infection of the disease that are propagated through a dead body of management and transportation must be very careful. Risk of infection that can occur between the deceased body and funeral directors, guideline of the preparation room and infection route of infection source has been studies in Korea. But the funeral director's working circumstances and infection blocking facility of the funeral home has not been studied in Korea. So we are investigated about the state of the working circumstances and Infection blocking facility within Metropolitan, Chungcheong and Gyeongsang regions in Korea. The result is as follows. The funeral directors have shown that there is difficult to get safe protection from infection. The personal hygiene of funeral directors and the infection blocking facility should be strengthened institutionally. We are thought to require more in-depth research about the working circumstances of funeral director and the infection blocking facility.

Flood Inundation Analysis in Urban Area Using XP-SWMM (XP-SWMM 모형을 이용한 도심지역 침수해석)

  • Kim, Jinsu;Lee, Wonho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Current domestic research is to demonstrate the effectiveness and efficiencies of flood prevention measures through one-dimensional numerical analysis and this study's object is to help water managers to make the efficient decisions by applying the two-dimensional urban run off model XP-SWMM model in the flooded area and comparing with the flood prevention measures. Statistics were analyzed, based on the data collected from Cheongju Weather Service from 1967 to 2011 for 45 years. 50 years Flood frequency simulations of water flow capacity analysis of the target area for flooded areas $539,548m^2$, inundation depth 1.0 m, was analyzed by inundation time of 48 minutes. When comparing with the constructions of bypass road and underground storage facilities to increase the water flow capacity of A1 small drainage areas as flood protection, if you install a batching target underground detention basin with a capacity of $13,500m^3$, it is expected that the flood by rainfall with frequency of 50 years will be resolved completely. In preparation for extreme weather in the future flood mitigation measures, underground storage tank installation is considered a better efficient way.

Fabrication of 5,000V, 4-Inch Light Triggered Thyristor using Boron Diffusion Process and its Characterization (Boron 확산공정을 이용한 5,000V, 4인치 광 사이리스터의 제작 및 특성 평가)

  • Park, Kun-Sik;Cho, Doohyung;Won, Jongil;Lee, Byungha;Bae, Youngseok;Koo, Insu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.411-418
    • /
    • 2019
  • Light-triggered thyristors (LTTs) are essential components in high-power applications, such as HVDC transmission and several pulsed-power applications. Generally, LTT fabrication includes a deep diffusion of aluminum as a p-type dopant to form a uniform p-base region, which needs careful concern for contamination and additional facilities in silicon semiconductor manufacturing factories. We fabricated 4-inch 5,000 V LTTs with boron implantation and diffusion process as a p-type dopant. The LTT contains a main cathode region, edge termination designed with a variation of lateral doping, breakover diode, integrated resistor, photosensitive area, and dV/dt protection region. The doping concentration of each region was adjusted with different doses of boron ion implantation. The fabricated LTTs showed good light triggering characteristics for a light pulse of 905 nm and a blocking voltage (VDRM) of 6,500 V. They drove an average on-state current (ITAVM) of 2,270 A, peak nonrepetitive surge current (ITSM) of 61 kA, critical rate of rise of on-state current (di/dt) of 1,010 A/㎲, and limiting load integral (I2T) of 17 MA2s without damage to the device.

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul (서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석)

  • Kim, Sung-Bum;Oh, Byung-Chil;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

Practical use of computational building information modeling in repairing and maintenance of hospital building- case study

  • Akhoundan, Majid Reza;Khademi, Kia;Bahmanoo, Sam;Wakil, Karzan;Mohamad, Edy Tonnizam;Khorami, Majid
    • Smart Structures and Systems
    • /
    • v.22 no.5
    • /
    • pp.575-586
    • /
    • 2018
  • Computational Building Information Modeling (BIM) is an intelligent 3D model-based process that provides architecture, engineering, and construction professionals the insight to plan, design, construct, and manage buildings and infrastructure more efficiently. This paper aims at using BIM in Hospitals configurations protection. Infrastructure projects are classified as huge structural projects taking advantage of many resources such as finance, materials, human labor, facilities and time. Immense expenses in infrastructure programs should be allocated to estimating the expected results of these arrangements in domestic economy. Hence, the significance of feasibility studies is inevitable in project construction, in this way the necessity in promoting the strategies and using global contemporary technologies in the process of construction maintenance cannot be neglected. This paper aims at using the building information modeling in covering Imam Khomeini Hospital's equipment. First, the relationship between hospital constructions maintenance and repairing, using the building information modeling, is demonstrated. Then, using library studies, the effective factors of constructions' repairing and maintenance were collected. Finally, the possibilities of adding these factors in Revit software, as one of the most applicable software within BIM is investigated and have been identified in some items, where either this software can enter or the software for supporting the repairing and maintenance phase lacks them. The results clearly indicated that the required graphical factors in construction information modeling can be identified and applied successfully.

Uncertainty Analysis and Application to Risk Assessment (위해성평가의 불확실도 분석과 활용방안 고찰)

  • Jo, Areum;Kim, Taksoo;Seo, JungKwan;Yoon, Hyojung;Kim, Pilje;Choi, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.425-437
    • /
    • 2015
  • Objectives: Risk assessment is a tool for predicting and reducing uncertainty related to the effects of future activities. Probability approaches are the main elements in risk assessment, but confusion about the interpretation and use of assessment factors often undermines the message of the analyses. The aim of this study is to provide a guideline for systematic reduction plans regarding uncertainty in risk assessment. Methods: Articles and reports were collected online using the key words "uncertainty analysis" on risk assessment. Uncertainty analysis was conducted based on reports focusing on procedures for analysis methods by the World Health Organization (WHO) and U.S. Environmental Protection Agency (USEPA). In addition, case studies were performed in order to verify suggested methods qualitatively and quantitatively with exposure data, including measured data on toluene and styrene in residential spaces and multi-use facilities. Results: Based on an analysis of the data on uncertainty, three major factors including scenario, model, and parameters were identified as the main sources of uncertainty, and tiered approaches were determined. In the case study, the risk of toluene and styrene was evaluated and the most influential factors were also determined. Five reduction plans were presented: providing standard guidelines, using reliable exposure factors, possessing quality controls for analysis and scientific expertise, and introducing a peer review system. Conclusion: In this study, we established a method for reducing uncertainty by taking into account the major factors. Also, we showed a method for uncertainty analysis with tiered approaches. However, uncertainties are difficult to define because they are generated by many factors. Therefore, further studies are needed for the development of technical guidelines based on the representative scenario, model, and parameters developed in this study.

Analysis of Environmental and Social Problems Caused by Photovoltaic Complex and Wind Farm Construction and Countermeasures to Mitigate the Problems (태양광 및 풍력단지의 개발에 따른 환경적·사회적 문제 분석 및 대응방안)

  • Ahn, Sewoong;Lee, Hi Sun
    • Journal of Environmental Policy
    • /
    • v.10 no.3
    • /
    • pp.3-20
    • /
    • 2011
  • Through case studies of photovoltaic complex and wind farm construction and management, the causes of environmental and social conflicts were analyzed. Policies and measures to minimize conflicts and complement the institution were identified by analyzing successful construction and management case studies from both domestic and abroad. The causes of problems were haphazard damages to the regional environment, direct damages from power production facilities, lack of regional benefits from power production businesses, and loose environmental restrictions and management. The countermeasures to mitigate the problems at hand are to improve and strengthen the guidelines for power production businesses, secure residents' acceptability, strengthen regulations for business explanation, increase stakeholder's participation, find alternative sites, and ensure the speedy implementation of on-shore wind farms. Through these countermeasures, specific goals included in the New Renewable Energy Master Plan, such as target goals for photovoltaic and wind energy, preservation and protection of environment, and improvement of residents' acceptability, can be achieved.

  • PDF

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.