• 제목/요약/키워드: Protection Facilities

검색결과 839건 처리시간 0.027초

소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구 (A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System)

  • 진승현;김혜원;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

대규모건축물적용 특수방재설비

  • 이성모
    • 한국화재소방학회논문지
    • /
    • 제10권4호
    • /
    • pp.37-42
    • /
    • 1996
  • The "Intelligent Fire detecting and Extinguishing System" is an up-to-date fire protection system for modern high-rise buildings, international airports, enormous industrial facilities, dome stadiums such as specific areas in which the application of our local fire protection regulation could not be satisfied. The state-of-the art initiating devices communicated with sophisticated network control panels enable peoples to get reliable and powerful suppressions using water or gas, providing absolute protection. The Intelligent Water Cannon System, the Low Pressure $CO_2$ System and the MXL Networking Fire Alarm System introduced in this paper accomplish the dynamic protection for the special hazards.

  • PDF

Radiological Dose Assessment Due to the Operation of Nuclear Facilities at KAERI Nuclear Site

  • Han, M.H.;Kim, E.H.;Hwang, W.T;Yeom, J.M.;Han, J.T.;Lee, Y.B.;Han, W.J.
    • Journal of Radiation Protection and Research
    • /
    • 제28권3호
    • /
    • pp.247-254
    • /
    • 2003
  • To prevent the potential health detriment to the public from radioactive effluents, radiological dose assessments due to the operation of nuclear facilities located at Korea Atomic Energy Research Institute (KAERI) site has been performed semiannually in compliance with the Minister of Science and Technology (MOST)'s Notice in Korea. Radiological dose assessment based on the new recommendation of the International Committee on Radiation Protection (ICRP-60) has been conducted since 1998. In this manuscript, a serial activities at KAERI site to meet the regulatory standards for routine releases of radioactive effluents are introduced and discussed including technical approaches. It is clear that each nuclear facility has been operated in compliance with regulatory standards. Furthermore, it is identified that the radiation induced health effects for residents around the site are neglectable.

지하철 역사의 안정적 전원공급을 위한 보호시스템 검토 (A study on present status and improvement of protection relay system in subway station for stable power supply)

  • 나종우;조원강;박동선;유연성;문화수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

정보통신기기용 과도전압 차단장치의 개발에 관한 연구 (A Study on the Development of a Transient Voltage Blocking Device for Info-communication Facilities)

  • 한주순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.159-167
    • /
    • 1999
  • This paper presents a new transient voltage blocking device(TOBD)which low power and high frequency bandwidth to protect info-communication facilities from transient voltages. Conventional protection devices have some problems such as low frequency bandwidth low ener-gy capacity and high remnant voltage. in order to improve these limitations a hybrid type TOBD which consists of a gas tube avalanche diodes and junction type field effect transistor (JFETs) is developed. The TOBD differs from the conventional protection devices in configuration and JFETs are used as an active non-linear element and a high speed switching diode with low capacitance limited high current. Therefore the avalanche diode with low energy capacity are protected from the high current and the TOBD has a very small input capacitance. From the performance test using combination surge generator which can produce $1.2/50{\mu}m$ 4.2 kV/max, $8/20{\mu}m$ 2.1 kAmax it is confirmed that the proposed TOBD has an excellent protection per-formance in tight clamping voltage and limiting current characteristics.

  • PDF

Impacts of sea-level rise on port facilities

  • Son, Chang-Bae;Kim, Chang-Je;Jang, Won-Yil;Matsubara, Yuhei;Noda, Hedeaki;Kim, Mi-Kum
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.2
    • /
    • pp.173-177
    • /
    • 2006
  • From the viewpoint of coastal hydrodynamics, one of the most important effects of global warming is a sea-level rise in coastal areas. In the present study, impacts on port facilities against sea-level rise were investigated. The sea-level rise causes the increase of the water depth, and it generates variations on the wave height, buoyancy, tidal system and nearshore current system and so on. The increase of water depth gives rise to the decrease of crown height of the structure and it causes increase of wave overtopping quantity. It may flood the port zone and its facilities, and may decrease harbor tranquility. It also leads to difficulties on navigation, mooring and loading/unloading at the port. Increase in water depth also causes increase of wave height in surf zone. This high wave makes structures unstable and may cause them to collapse during storm. In addition, increase in buoyant force due to sea-level rise also makes the gravity type structures unstable. Consequently, theses variations due to sea-level rise will cause functional deterioration of port facilities. In order to protect port facilities from the functional deterioration, reinforcement plan is required such as raising the crown height and increase in block weight and so on. Hence proper estimation method for the protection cost is necessary in order to protect port facilities efficiently. Moreover response strategies and integrated coastal zone management plan is required to maintain the function of port facilities. A simple estimation of cost for breakwaters in Korea was performed in the present study.

  • PDF

방사선안전관리를 위한 Process Mapping 개발 (Development of the Process Mapping for the Radiation Safety Management)

  • 이용식;이진우;이윤종
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.149-156
    • /
    • 2013
  • 최근 국내 방사선이용기관 수의 증가와 시설의 다양한 투자로 운영 및 안전관리가 복잡해지고 있다. 그러나 작업종사자 수와 방사선 시설증가에도 불구하고 방사선안전관리자 인력은 증가되지 않고 있는 실정이며, 소수의 방사선안전관리자에 의해 방사선작업종사자 등록 및 관리, 선원관리, 방사선량 감시, 배기 및 배수 등의 많은 업무가 관리되고 있다. 이러한 문제점은 방사선 사고발생의 직 간접적인 사고의 원인이 되고 있다. 본 연구에서는 방사선을 이용하는 시설의 효율적인 안전관리와 사고예방을 위한 방사선안전관리 업무절차를 도식화(Process Mapping)하였다. Process Mapping 개발을 위해 방사선안전관리 현안요건을 분석하고, 개별 절차상의 업무분석을 통해 방사선안전관리 체계를 정비하였다. 개발한 Process Mapping을 바탕으로 각 기관에 적합한 업무절차의 흐름을 명확히 구성함으로써 방사선을 이용하는 시설의 안전 위해 요인을 줄이고 방사선안전관리 체계를 개선할 수 있으며, 필요에 따라 Process Mapping을 수정보완하여 방사선안전관리에 효과적으로 사용할 수 있다.

Neutron Dosimetry and Monitoring in the Radiation Environment

  • Nakamura, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.51-62
    • /
    • 1989
  • The high efficiency moderated-type neutron spectrometer and doseequivalent counter were developed for the measurement of low level environmental neutrons. By using these detectors, the neutron energy spectra and dose equivalent rates due to skyshine effect were measured in the environment surrounding the accelerator facilities and also the altitude variation of cosmic ray neutrons in the aircraft flying over Japan.

  • PDF

긴급서어비스 시설의 적정소요 및 배분 (A Study on an Optimal Requirement and Allocation Planning of Emergency Service Facilities)

  • 황학;황흥석;정호원
    • 한국경영과학회지
    • /
    • 제6권1호
    • /
    • pp.75-82
    • /
    • 1981
  • This paper considers urban emergency service systems that dispatch vehicles (facilities) from fixed bases with the objective of finding an optimum allocation of emergency facilities. A case study of fire station problem of Seoul city is conducted to analyze the deployment of fire-fighting resources and develop a class of improved deployment strategies with Parameteric Allocation Model (P.A.M.). The study shows a long term plan leading to balanced fire protection for most fire hazardous districts as well as low alarm districts.

  • PDF

직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구 (A study of Protection for electrical corrosion by stray current in DC railway system)

  • 이재영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF