• 제목/요약/키워드: Protection Facilities

검색결과 845건 처리시간 0.31초

노인요양시설 피난계획 제도적 개선방안 연구 (A Study on the Reform of the Evacuation Planning in the Nursing home for the Elderly)

  • 김윤정;김석준;윤명오
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제15권1호
    • /
    • pp.13-22
    • /
    • 2009
  • The nursing home for the elderly has a weak point for evacuation from the fire because most of all the users are suffering from a dementia or paralysis. When it comes to night shift, it is much difficult to get them evacuated due to the lack of staffs. In addition to that, the nursing home for the elderly has such a strict control system for access that does not have a utility for escape opening. That is why they need the differentiated evacuation planning. This study is to consider the point at issues on the present conditions of law, system, and evacuation plans for the nursing home for the elderly that has some difficulties because of impaired functions of residences. This study dealt with the point at facilities and operations of the emergency evacuation system. First of all, for the point at the facilities, I found that it need to be considered on the characteristics of the elderly who has any difficulties of the self evacuation. And the established regulation did not reflect the characteristics of closed area of the nursing home for the elderly. The second, for the point at the operation of the institutions, it is pointed that there seems to be a lack of ways to manage to a emergency situation and educations on the operation staff. And the last, for the point at the operation, the requirement for the managers of fire prevention facilities are similar to that of a normal building. Furthermore there is a lack of corporation with the fire station.

  • PDF

매장문화재에 대한 보존과학의 역할 (Role of the Conservation Science in Excavating Objects)

  • 이상수;강대일
    • 보존과학회지
    • /
    • 제6권2호
    • /
    • pp.119-125
    • /
    • 1997
  • 출토된 매장문화재의 소장관리책임은 문화재보호법 제3644호에 따라 국립박물관에 있다. 이러한 문화재는 연간 10,000여점 씩이나 폭증하고 있고 이 숫자는 앞으로 더욱 증가할 전망이다. 한편 국립박물관의 보관시설은 이미 포화상태를 넘은 상황이며, 따라서 출토문화재는 열악한 시설과 인력이 태부족한 대학박물관 등에 위탁 관리되는 형편이라서 부실보관 등 원초적인 문제가 야기되고 있다. 더 큰 문제점은 이들 문화재가 과학적인 보존처리 및 관리의 보호를 받지 못한다는 점인데 그 이유는 보존과학자가 국립박물관에 5명이며 독립부서조차 없는 실정이고, 전국적으로는 20여명밖에 없기 때문이다. 이러한 출토문화재의 보존관리 문제를 해결하기 위해서는 새로운 제도 및 기구(가칭: 매장문화재 통합보존소)가 시급히 마련되어야 하며, 가장 효과적인 방안으로는 과학적인 수장시설의 설치와 이를 관리할 수 있는 전문인력(보존과학자)으로 구성된 기구의 설립이 절실하므로 이를 제안하는 바이다.

  • PDF

도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정 (Estimation of Storage Capacity for CSOs Storage System in Urban Area)

  • 조덕준;이정호;김명수;김중훈;박무종
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구 (A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility)

  • 박재성
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.93-102
    • /
    • 2009
  • 최근 보육시설의 확충과 보육환경의 개선, 보육서비스 질 향상에 대한 사회적 욕구는 급속히 증가하고 있으며, 특히 화재 등으로부터 안전환경 확보가 범국가적 이슈로 대두되고 있다. 보육시설은 영유아 등 재실자의 대부분이 피난능력이 떨어지는 재해약자로 구성되어 건물 내 설치층수, 피난시설의 설치 적정성 등이 피난안전을 좌우하는 중요한 요소이다. 본 연구에서는 보육시설 설치현황, 국내외 관련 기준의 비교분석, 피난 관련 시설의 실태조사 등을 통하여 보육시설 피난안전성 측면에서의 문제점과 개선요소를 파악하였다. 그 결과 화재안전 관련 법규정의 체계화, 비상재해대비시설의 설치기준 및 관리에 대한 소방기관과의 연계, 스프링클러 등 보다 강화된 소방설비 설치규정의 개선, 화재위험시설과 동일 건물 내 설치금지 등이 필요한 것으로 분석되었다.

회귀분석을 이용한 비상대피시설의 출입구 개수 적정성에 관한 연구 (A Study on the Suitability of the Number of Entrances for Emergency Evacuation Facilities Using Regression Analysis)

  • 노정헌;이정문;김국주;박영준
    • 한국건축시공학회지
    • /
    • 제19권5호
    • /
    • pp.431-438
    • /
    • 2019
  • 본 연구에서는 비상대피시설의 출입구 개수 산정의 적정성을 평가하고자 하였다. 현행 민 관 군 대피시설의 기준은 대피 인원이 대피를 완료한 상황을 가정하여 적정 건축면적을 보유하도록 하는 정태적 기준만을 제시하고 있다. 그러나 실제 대피상황을 감안한다면 건축면적과 같은 정태적 기준보다는 출입구 개수, 대피인원, 대피시간 등과 같은 동태적 기준을 동시에 고려할 필요가 있다. 이를 위해 동태적 기준이 대피시간에 어떠한 영향을 주는지 대피 시뮬레이션을 통해 매개변수 연구와 회귀분석을 실시하였다. 그 결과를 대피시간에 대한 추정 모델을 개발하고 대피인원대비 적정 출입구 개수를 제시하였다.

매장문화재(埋藏文化財)에 대한 보존과학의 역할(役割) (Role of the Conservation Science in Excavating Objects)

  • 이상수
    • 박물관보존과학
    • /
    • 제1권
    • /
    • pp.9-14
    • /
    • 1999
  • 출토된 매장문화재의 소장관리책임은 문화재보호법 제3644에 따라 국립박물관에 있다. 이러한 문화재는 연간 10,000여점 씩이나 폭증하고 있고 이 숫자는 앞으로 더욱 증가될 전망이다. 한편 국립박물관의 보관시설은 이미 포화상태를 넘은 상황이며, 따라서 출토문화재는 열악한 시설과 인력이 태부족한 대학박물관 등에 위탁 관리되는 형편이라서 부실보관 등 원초적인 문제가 야기되고 있다. 더 큰 문제점은 이들 문화재가 과학적인 보존처리 및 관리의 보호를 받지 못한다는 점인데 그 이유는 보존과학자가 국립박물관에 5명이며 독립부서조차 없는 실정이고, 전국적으로는 20여명 밖에 없기 때문이다. 이러한 출토문화재의 보존관리 문제를 해결하기 위해서는 새로운 제도 및 기구(가칭 : 매장문화재 통합보존소)가 시급히 마련되어야 하며, 가장 효과적인 방안으로는 과학적인 수장시설의 설치와 이를 관리할 수 있는 전문인력(보존과학자)으로 구성된 기구의 설립이 절실하므로 이를 제안하는 바이다.

지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발 (Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures)

  • 하윤철;배정효;하태현;이현구;이재덕;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

콘크리트구조물 보수용 방식피복재의 특성 (A Study on the Properties of Anticorrosive for RC Structure)

  • 문한영;신동구;권영진;오상근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.251-258
    • /
    • 2005
  • 지금까지의 대부분의 방수 방식 및 보수 등의 보호마감설계는 외부환경으로부터 콘크리트의 보호차원에서 목표재료성능을 중시 하였으나 시공과정에서 콘크리트바탕자체와의 상응성을 충분히 검토하지 못함으로서 그 요구수명을 다하지 못한 사례가 많다. 따라서 본 연구는 상하수시설 및 항만시설 등과 같은 콘크리트구조물에 있어서 콘크리트를 보호하기 위한 방식피복재의 내구성으로 수밀성, 내화학성 및 내마모성의 평가 결과 방식피복재 A 및 B형 모두 성능이 우수한 것으로 나타났다. 또한 바탕의 건조/습윤 조건, 방식피복재 도포후의 양생조건 및 다양한 온도조건에서 부착성능을 평가한 결과, 모든 경우에 있어서 기준치인 부착강도 $15kgf/cm^2$보다 정도 큰 값을 나타내었다. 또한 현장 적용성 평가로 실구조물 2곳에 대한 시험시공 결과 방식피복재 A 및 B형 모두 기준값 이상으로, 상하수도 및 지하철 시설물과 같은 콘크리트 구조물의 방수 방식 및 보수재료로서 사용이 적합한 것으로 판단된다.

주요 정보통신기반시설의 평가컨설팅 방법론에 대한 연구 (A Study on the Evaluation Consulting Methodology of Important Information Communication Base Facility)

  • 이영로;조재완
    • 디지털융복합연구
    • /
    • 제5권1호
    • /
    • pp.55-68
    • /
    • 2007
  • It soaks but 2001 July information communication base step law enforcement and the Enforcement Ordinance are published to follow, in order to support the establishment of evaluation and protective measure in order the vulnerability analysis against the facility of the agency which manages an important information communication base hour opinion to designate information protection specialty enterprise. As information protection specialty enterprise being revealed evacuation laboratory back 12 enterprises from information communication department become designation as the consulting enterprise and they do an enterprise activity actively. It follows in diffusion of the IT and information reconciliation level the other side where our country belongs in the world-wide first group, the research against the disfunction plan of preparation comparison the fact that law it is come negligently all actuality. The network as it will give management coat fatal effect even at obstacle occurrence hour of instant for of case and IT facility of the cyber transactions which leads, in the future there to be to corporate management, there is a possibility the stable civil official of information Facilities for communications very seeing in the portion which is important. Present condition and important propulsion contents of information communication base step law enforcement after, against a vulnerability analysis of information protection relation field and evaluation consulting methodological application situation to sleep it researches from the dissertation which it sees consequently and it does.

  • PDF

VIPEX를 이용한 가상 원자력시설의 핵심구역 파악 분석 (Vital Area Identification Analysis of A Hypothetical Nuclear Facility Using VIPEX)

  • 이윤환;정우식;이진홍
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.87-95
    • /
    • 2011
  • The urgent VAI(Vital Area Identification) method development is required since 'The Act of Physical Protection and Radiological Emergency' that is established in 2003 requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The KAERI(Korea Atomic Energy Research Institute) has developed the VAI methodology and VAI software called as VIPEX(Vital area Identification Package EXpert) for identifying the vital areas. This study is to demonstrate the applicability of KAERI's VAI methodology to a hypothetical facility, and to identify the importance of information of cable and piping runs when identifying the vital areas. It is necessarily needed to consider cable and piping runs to determine the accurate and realistic TEPS(Top Event Prevention Set). If the information of cable and piping runs of a nuclear power plant is not considered when determining the TEPSs, it is absolutely impossible to acquire the complete TEPSs, and the results could be distorted by missing it. The VIPEX and FTREX(Fault Tree Reliability Evaluation eXpert) properly calculate MCSs and TEPSs using the fault tree model, and provide the most cost-effective method to save the VAI and physical protection costs.