• Title/Summary/Keyword: Protection Device

Search Result 780, Processing Time 0.052 seconds

The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy (촬영 및 투시용 X선 장치의 기본안전과 필수 성능에 관한 개별 기준규격의 동향)

  • Roh, Young Hoon;Kim, Jung Min
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.331-336
    • /
    • 2015
  • Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipments.

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

Effects of Temperature and Photoperiod on Male Activity in Laspeyresia pomonella (L.) in New York (온도와 광주기 조건이 코드링나방 수컷의 활동력에 마치는 영향)

  • SONG, YOO HAN;Ridel, Helmut
    • Korean journal of applied entomology
    • /
    • v.24 no.2 s.63
    • /
    • pp.71-77
    • /
    • 1985
  • The male activity in Laspeyresia pomonella (L.) measured by an activity recording device in New York had two distinct peaks, the first peak at lights-off and the second one at ligts-on signal, under the defined conditions of temperature above $23^{\circ}C$ and light:dark (LD) 16:8 regime. The activity initiation of the first activity was observed four to six hours prior to the onset of scotophase and seened to be entraind by lights-off cue. Under the continuous photophase (LL) the activity period freeran with a period slightly greater than 24 hours, indicating that the rhythmicity is circadian The activity pattern was measured in eight different temperature conditions ranging from $11.3^{\circ}\;to\;30^{\circ}C$ under LD 16:8 regime. No activity was observed at $11.3^{\circ}C$ which seems to be temperature threshold for activity. The second peak of activity at lights-on signal disappeared at the temperature below $20^{\circ}C$ and the activity in scotophase was also suppressed at the temperature lower than $18^{\circ}C$. At the temperature range from $20^{\circ}\;to\;30^{\circ}C$, as temperature increased the second peak in the morning became larger and the activty in the scotophase was also increased. Because of the activity increase in the scotophase with rising temperature, the mean time of activity shifted towards the scotophase. The shift of the moth male activity period with the change of ambient temperature appears to be due to the suppression of activity under cool temperature (below $20^{\circ}C$) in scotophase.

  • PDF

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

Fall Risk Assessment of the Elderly living in Nursing Home (노인요양시설 거주 노인의 낙상 위험요인 조사 연구)

  • Yang, Sun-Hee;Park, Young-Hae;Cho, Hae-Sook;Baek, Hee-Chong
    • Journal of Home Health Care Nursing
    • /
    • v.12 no.2
    • /
    • pp.1-15
    • /
    • 2005
  • Purpose: This study was conducted to assess the fall risk factors. Method: The subjects were 87 persons who were older than 65 years living at 28 nursing home in Seoul and Gyunggi province. Subjects were interviewed using RAFS II for intrinsic factor and the environmental factor were assessed using a structured questionnaire from Oct. to Dec. in 2004. The data were analyzed by SPSS(ver. 12.0) programs, using descriptive statistics, $x^2$-test, and t-test. Result: The 37.9% of the subjects experienced the fall, and its average number is $1.94\pm1.75$. The Women's experience of the fall was higher than that of the men, but it was no significant difference with gender. There was no significant difference with the age and duration of living. The mean of the intrinsic risk factor was 13.38 in total score 39 points marks on the RAFS II scales. The intrinsic risk factor score of the fallen group 15.71 was significantly higher than the non-fallen group 12.10. The variables of recent fall experience(t=4.72, p=0.000) and urinary dysfunction(t=2.64, p=0.010) was significantly higher than the non-fallen group. The highest variable of the intrinsic factor was the age and the variables of drug intake, balance, chronic disease, recent fall experience, urinary dysfunction were followed in order. The mean of the environmental risk factor was 0.24 points. No significant differences were shown in environmental risk factor between the fallen and the non-fallen groups. To the fallen group, the place of entrance was the highest risky environmental factor. To see in area dimension, the floor surfaces was the highest risky environmental factor and equipment and illumination factor was the following risky elements in order. In the total score of environmental risk factors based on the ares, the fallen group was 0.26 and the non-fallen group was 0.24, but there were no significant differences between the groups. Conclusion: This results suggested that visual protection strategy, set up the safety device in the place of entrance and inner stairway, bathroom and nonskid mat in the nursing home would be contribute to the prevention of the fall for the elderly.

  • PDF

Effects of Passivation Thin Films by Spray Coatings on Properties of Flexible CIGS Solar Cells (스프레이코팅법에 의한 패시베이션 박막이 플렉시블 CIGS 태양전지의 특성에 미치는 영향)

  • Lee, Sang Hee;Park, Byung Min;Kim, Ki Hong;Chang, Young Chul;Pyee, Jaeho;Chang, Ho Jung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.57-61
    • /
    • 2016
  • In order to protect the solar cells from the moisture and oxygen, we evaluated the electrical and optical properties for the $Cu(In,Ga)Se_2$ (CIGS) solar cells which were prepared by the spray coating method. Generally, the EVA (ethylene-vinyl acetate) films are laminated to protect the CIGS flexible solar cells, which results in a high cost process due to complicated devices. In this study, we tried to prepare the protection layers of the flexible CIGS flexible solar cells by using spray coating method instead of conventional laminating films in order to reduce the device weight as well as the process time. The CIGS solar cells with spray coating method showed an enhanced efficiency than the before treated sample (2.77% to 2.93%) and relatively proper water vapor transmission rate of the solar cells about 62.891 gm/[$m^2-day$].

Effect of 840 nm Light-Emitting Diode(LED) Irradiation on Monosodium Iodoacetate-Induced Osteoarthritis in Rats (흰쥐의 MIA 유발 무릎 뼈관절염에 대한 840 nm LED의 효과)

  • Jekal, Seung-Joo;Kwon, Pil-Seung;Kim, Jin-Kyung;Lee, Jae-Hyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.151-159
    • /
    • 2014
  • PURPOSE: The purpose of this study was to evaluate whether light-emitting diodes (LED) irradiation could be effective in a noninvasive, therapeutic device for the treatment of osteoarthritis(OA). METHODS: Twenty-four male Sprague-Dawley rats were divided into four groups: Vehicle control (saline); monosodium iodoacetate-injection (MIA); LED irradiation after MIA injection (MIA-LED); indomethacin-treatment after MIA injection (MIA-IMT). OA was induced by intra-articular injection of 3 mg MIA through the patellar ligament of the right knee. Vehicle control rats were injected with an equivalent volume of saline. The LED was irradiated for 15 min/day for a week after 7 days of MIA treatment. To compare with the effect of LED irradiation, the indomethacin was administrated 20 mg/kg twice a week orally after 7 days of MIA treatment. Knee joints were removed and fixed overnight in 10% neutral buffered formalin and decalcified by EDTA for 2 week before being embedded in paraffin. The assessment of OA induction were monitored by knee movement and radiographic finding. Histologic analysis were performed following staining with hematoxylin and eosin, safranin O-fast green, or toluidine blue, picrosirius red, and histologic changes were scored according to a modified Mankin system. Apoptotic cell in tissue sections was detected using TUNEL method. RESULTS: Radiographic examination could not show the differences between the MIA-treated and the MIA-LED-treated rats. In the histologic analysis, however, LED irradiation prevented cartilage damage and subchondral bone destruction, and significantly reduced mononuclear inflammatory cell infiltration and pannus formation. LED irradiation also reduced apoptosis of cartilage cells, but it prevented apoptosis of infiltrated inflammatory cells in synovium. In addition, LED irradiation showed an increase of collagen production in the meniscus. CONCLUSION: These results suggest that the 840 nm LED irradiation would be a suitable non-thermal phototherapy for the treatment of OA, as a cartilage protection and anti-inflammatory modality.

Effects of Posttraumatic Hypothermia in an Animal Model of Traumatic Brain Injury(TBI) - Immunohistochemical Stain by TUNEL & β-APP - (실험적 외상성 뇌손상모델에서 외상 후 저체온법의 효과 - TUNEL과 β-APP Immunohistochemical Stain -)

  • An, Byeong Kil;Ha, Young Soo;Hyun, Dong Keun;Park, Chong Oon;Kim, Joon Mee
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.461-470
    • /
    • 2000
  • Objective : Many investigators have demonstrated the protective effects of hypothermia following traumatic brain injury(TBI) in both animals and humans. It has long been recognized that mild to moderate hypothermia improves neurologic outcomes as well as reduces histologic and biochemical sequelae after TBI. In this study, two immunohistochemical staining using terminal deoxynucleotidyl-transferase-mediated biotin dUTP nick end labeling(TUNEL), staining of apoptosis, and ${\beta}$-amyloid precursor protein(${\beta}$-APP), a marker of axonal injury, were done and the authors evaluated the protective effects of hypothermia on axonal and neuronal injury after TBI in rats. Material and Method : The animals were prepared for the delivery of impact-acceleration brain injury as described by Marmarou and colleagues. TBI is achieved by allowing of a weight drop of 450gm, 1 m height to fall onto a metallic disc fixed on the intact skull of the rats. Fourty Sprague-Dawley rats weighing 400 to 450g were subjected to experimental TBI induced by an impact-acceleration device. Twenty rats were subjected to hypothermia after injury, with their rectal temperatures maintained at $32^{\circ}C$ for 1 hour. After this 1-hour period of hypothermia, rewarming to normothermic levels was accomplished over 30-minute period. Following 12 hours, 24 hours, 1 week and 2 weeks later the animals were killed and semiserial sagittal sections of the brain were reacted for visualization of the apoptosis and ${\beta}$-APP. Results : The density of ${\beta}$-APP marked damaged axons within the corticospinal tract at the pontomedullary junction and apoptotic cells at the contused cerebral cortex were calculated for each animal. In comparison with the untreated controls, a significant reduction in ${\beta}$-APP marked damaged axonal density and apoptotic cells were found in all hypothermic animals(p<0.05). Conclusion : This study shows that the posttraumatic hypothermia result in substantial protection in TBI, at least in terms of the injured axons and neurons.

  • PDF

A Study on the Usage of Investigation of Google Cloud Data (Smartphone user-oriented) (구글 클라우드 데이터의 수사활용 방안에 관한 연구 (스마트폰 사용자 중심))

  • Kim, Dongho;Lee, Sangjin
    • Journal of Digital Forensics
    • /
    • v.12 no.3
    • /
    • pp.109-120
    • /
    • 2018
  • The smartphone is the communication device that is the most personal to the user, and it keeps a lot of information related to the user and makes information communication with other devices. With these characteristics, forensics on smartphones are one of the most basic methods of investigation in criminal investigations, and have actually contributed to the settlement of the case by providing many clues. However, recently, it is designed to encrypt data stored as a social issue related to the protection of user's personal information, or to delete deleted data or to delete log data together. So, any solutions? In this paper, I try to find the answer from cloud data stored by smartphone user account. Cloud forensics should approach complementary relationships rather than smartphone forensics. There are a lot of data stored in the cloud that can be meaningfully used in the investigation. Online activity information of users, such as Internet usage, YouTube view, and contents purchase information, cloud service such as e-mail, cloud drive, and location information are the most representative data. These data can be unvaluable, but here are some important clues in various types of criminal investigations. In this paper, I propose a method to extract data from the google cloud so that the data can be used for investigation, and to utilize the extracted data for investigation. And it explains the role of the extracted artifacts in the actual investigation business through virtual cases and proves its value.

A Study on Development of Mobile LNG Yard Tractor Refueling Standards (이동식 LNG 야드트랙터 충전 기준 개발 연구)

  • Ryou, Young-don;Yu, Chul-hee;Koo, Bon-deuk;Lee, Dong-won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.59-64
    • /
    • 2018
  • As part of measures to reduce fine dust, the government is promoting a project to convert the fuel of Yard Tractors(YT, tractors operated at ports), from diesel to LNG (Liquefied Natural Gas). While a port having a small number of yard tractors, it is not proper to construct a stationary LNG fueling station and supply LNG to YT due to a problem of BOG (Boil off gas) generation. Therefore, it is necessary to make a regulation and a standard on mobile LNG YT refueling station installation and inspection as an alternative. In this study, we have investigated domestic and foreign mobile LNG refueling cases and refueling standards, including the USA and Europe. In addition, we have suggested the risk reduction method according to the cause after investigation of the cause of LNG accidents. And last, based on the proposed risk reduction measures, we have proposed an amendment to the Regulation of the Urban Gas Business Law in Korea. The proposed mobile LNG YT refueling amendment of the Regulation includes ; maintenance of the safety distance from the protection facility, installation of an interlock device to prevent refueling in places other than the authorized place, installation of the identification system through biometrics, separation of the tank lorry and tow vehicle before refueling, checking the wheel fixed status of tank lorry before refueling, construction of the impounding area, safety measures before, during and after refueling, etc. The safety standards proposed in this study could be used as a reference in establishing standards for mobile LNG vehicle refueling in the near future.