• 제목/요약/키워드: Protecting concrete

검색결과 101건 처리시간 0.024초

Activating Temperature of Kaolin As a Cement Admixture

  • Park, Hee-Yong;Hwang, Hey-Zoo;Kim, Moo-Han;Kim, Moon-Han
    • KCI Concrete Journal
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 2001
  • This research concerns the effect of kaolin as material of cement admixture. which has the advantage of low price and high adaptability. Kaolin, a kind of soil, is well known as a raw material of pottery. which is widely scat-tered on the earth (especially in Korea). This research shows the method and process for activating kaolin to have the properties of a cement admixture through experiment. In the experiments, kaolin is baked in high temperature and then cooled suddenly to be activated. The temperature zone and time span, on which kaolin is activated are examined. The research looks over the effect of the activated kaolin based on several criteria regarding to chemical and physical characteristic of general admixtures. The results of this research are as follows; kaolin start activation at the temperature above 50$0^{\circ}C$ and make ends of activation at the temperature below 95$0^{\circ}C$ and there was little effect by the change of duration. It is concluded that compressive strength can be increased by putting activated kaolin in the concrete and the activated kaolin is good for water resistance and anti-chemical , and that it is effective for protecting the leakage of hazardous article like Cl- and for protecting damage by an organic salt like acid. The activated kaolin of proper temperature and time is effective in compressive strength, salt resistance and acid resistance. The adaptability of activated kaolin as a cement admixture was shown through this research.

  • PDF

철근의 영향과 앵커 충돌각도를 고려한 유연콘크리트 매트리스의 손상평가 (Damage Evaluation of Flexible Concrete Mattress Considering Steel Reinforcement Modeling and Collision Angle of Anchor)

  • 류연선;조현만;김서현
    • 한국해양공학회지
    • /
    • 제30권2호
    • /
    • pp.109-116
    • /
    • 2016
  • A flexible concrete mattress (FCM) is a structural system for protecting submarine power or communication cables under various load types. To evaluate its of protection performance, a numerical analysis of an FCM under an anchor collision was performed. The explicit dynamics of the finite element analysis program ANSYS were used for the collision analysis. The influences of the steel reinforcement modeling and collision angle of the anchor on the collision behavior of the FCM were estimated. The FCM damage was evaluated based on the results of the numerical analysis considering the numerical modeling and collision environment.

PE 도막철근의 휨거동에 대한 실험적 연구 (Experimental Investigations on the Flexural Behavior Using PE-Coated Rebars)

  • 김영진;강영종
    • 한국방재학회 논문집
    • /
    • 제3권3호
    • /
    • pp.143-150
    • /
    • 2003
  • 최근의 철근콘크리트 구조물의 부식현상은 경제 사회적인 문제를 야기시키고 있다. 콘크리트내 철근의 부식을 방지하고 내구성을 향상시키고자 PE도막철근을 이용하여 구조적 성능을 실험적으로 검증 하였다. 에폭시도막, 무도막과 PE도막철근의 세가지 재료에 대하여 휨실험을 수행하였고 그 결과치를 비교 검증하였다. 하중-변위간의 관계를 통하여 무도막철근과 에폭시도막철근보다는 PE도막철근의 성능이 다소 우수함을 보였다. 이러한 결과를 통하여 도막재료에 시멘트를 살포하였던 것이 부착성능을 향상 시켰을 것으로 사료된다.

단면복구용 폴리머 모르타르의 염소이온 투과성 평가 (Performance Evalution of Chloride Ion Penetration of Polymer Mortar for Section Restoration)

  • 박성우;강동수;한복규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.285-288
    • /
    • 2006
  • Recently, polymer mortar has been developed not only more improving the performance of modified mortar with polymer, but also protecting and repairing materials of structures, especially in marine environment because of their excellent performance to improve compressive strength, flexural strength, and adhesive strength. however, in fact, these rehabilitation techniques in marine environment, which consist of removing delaminated areas of concrete, cleaning affected steel and patching with polymer mortar, have proven to be ineffective for marine structures. Also, repairs are often repeated every several years. Therefore, it is neccessary to research performance evalution of chloride ion penetration of polymar mortar for section restoration.

  • PDF

라텍스 모르타르를 이용한 콘크리트 교면 방수층 보호 공법 개발 및 적용에 관한 연구 (Application and Development of Protect Technique for waterproofing Reinforced Concrete Bridge Decks by Latex-Modified Mortar)

  • 한상일;이원영;김재원;강승희;차동화;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.175-178
    • /
    • 2009
  • This study is thing for construction properties that protect about damage of waterproofing course that is problem in asphalt pavement and latex modification concrete pavement. It is thing about new method of construction and develop protecting material of waterproofing. Did performance test item first at, as a result, drew by suitable thing in all KS items, This is considered to have more effective spot construction work because if means that have stability by material as well as method construction.

  • PDF

콘크리트 구조물용 유황폴리머 표면보호재의 내구성능 및 생물독성 (Durability and Bioassay of a Sulfur Polymer Surface Protecting Agent for Concrete Structures)

  • 석병윤;이병재;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.29-36
    • /
    • 2015
  • 본 연구에서는 유황을 폴리머화하여 콘크리트 표면보호재로 활용가능성을 검토하기 위하여 내구성능 및 생물독성 평가를 실시하였다. 평가 결과, 콘크리트 표면보호재의 내화학성능은 산, 알칼리 용액에 대하여 화학저항성이 우수한 것으로 나타났다. 배합조건별 촉진내후성 실험 후 부착강도평가 결과 규사분말 및 플라이애시를 동시에 혼합한 배합에서 가장 우수한 강도특성을 나타내었다. 콘크리트용 표면보호재 시험체의 온냉반복 후에도 모든 배합조건에서 부착강도 1 MPa을 상회하였고, SFS배합에서 가장 높은 부착강도를 나타내었다. 표면보호재를 도포한 콘크리트의 촉진탄산화 및 염소이온침투저항성을 검토한 결과, 규사분말을 채움재로 사용한 표면보호재를 도포한 시험체에서 가장 우수한 내구성능을 나타내었다. 유황폴리머를 콘크리트 표면보호재로 사용시 생물독성 검토를 위해 어독성 실험을 수행한 결과, 유황폴리머는 생물에 미치는 영향은 없는 것으로 나타났다. 표면보호재의 내화학성, 동결융해저항성, 탄산화, 염소이온침투저항성 등을 모두 고려하여 볼 때, 본 연구범위에서는 유황폴리머에 채움재로서 규사분말과 플라이애시를 각각 20%씩 대체하는 것이 적절한 수준인 것으로 판단된다.

고강도 철근콘크리트 기둥의 폭열제어를 위한 최적의 PP섬유함유량 산정 (Estimation of Optimum PP Fiber Content for the Spalling Control of High Strength Reinforced Concrete Columns)

  • 김인기;유석형;신성우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.155-163
    • /
    • 2007
  • 고강도 콘크리트(HSC)는 화재 시 폭렬현상과 함께 부재가 취성적인 거동을 하게 되는 단점을 지니고 있다. 폭렬현상은 화재 시 $100{^{\circ}C}$이상에서 부재내부의 수분 증발로 인하여 발생한 수증기가 수밀한 콘크리트에 갇혀 발생한다. 따라서 콘크리트 강도가 증가 할수록 수밀성이 높아져 폭렬의 정도가 심해진다. 콘크리트의 폭렬을 제어할 수 있는 방안으로는 폴리프로필렌 섬유(PP섬유)를 혼입하는 방법이 가장 효율적인 것으로 보고 되었다. 본 연구에서는 콘크리트 강도와 PP섬유 함유량을 변수로 하는 기둥 실험체에 대한 내화실험과 잔존강도실험을 수행하여 폭렬현상을 관찰하고 잔존강도를 측정하였다. 그 결과 콘크리트 강도가 60MPa에서 85MPa로 증가할 때 기둥 실험체의 잔존 축 강도는 10%증가하였다. 또한, PP섬유 함유량이 0%에서 0.2%까지 증가 할수록 잔존 축강도비는 68%에서 85%까지 증가하였으나, PP섬유 함유량이 0.2%이상에서는 잔존강도의 증가가 거의 나타나지 않았다.

도막재료에 따른 철근의 부착성능에 관한 실험적 고찰 (Experimental Study of Bond Properties Using Coated Bars)

  • 김영진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.211-216
    • /
    • 2003
  • Coated bars are protecting reinforcing bars from corrosion and enhancing durabilities of reinforced concrete structures are tested to evaluate corrosion protection properties. Tests are performed based on the relevant standards of ACI and ASTM, such as chemical resistance, salt water spray, salt crack test and chloride permeability test with the main variable of the coating thickness. Three type materials are tested by Polyethylene, epoxy and bare bar. Test results show good chemical protection property and chloride permeability. Polyethylene coated bar is good coating material than any other materials.

  • PDF

에폭시 도막 철근의 내부식 성능에 관한 실험적 연구 (Perforrmance Tests of Epoxy-coated Reinforcing Bars : Corrosion Protection Properties)

  • 신영수;홍기섭;최완철
    • 콘크리트학회지
    • /
    • 제6권6호
    • /
    • pp.173-179
    • /
    • 1994
  • 콘크리트내 철근의 부식을 방지하여 내구성을 증대시키기 위해 국내에서 시험 생산한 에폭시도막 철근의 내부식성능을 실험, 평가하였다. 본 연구에서는 국내 산업규격(KS)과 미국재료시험기준 시험결과로부터 에폭시도막 철근을 내약품성능, 염화물 투과성은 양호하였다. 그러나, 에폭시도막 철근표면의 결함부에서 부식이 발생되었으며 도막두계 $200{\mu}m$ 미만의 시험체에서 부식발생률이 높았다. 4mm 정도의 부분에폭시 도막손상은 전체적인 부식에 영향을 미치지는 않았다. 도막의 결함이 생기지 않도록 에폭시도막 과정에서 철근의 표면처리에 주의가 특별히 필요하다.

프리캐스트 콘크리트 교량바닥판 female-female이음부의 전단실험 (shear Tests on female-to-female Type Joint between Precast Concrete Bridge Decks)

  • 김영진;김영진;김종희
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.161-168
    • /
    • 1998
  • 본 연구는 수직전단하중에 대한 프리캐스트 바닥판간 이음부거동을 규명하고 수직전단력 전달에 유리한 이음부 구조도출을 위해 female-female 형식의 이음부를 제안하고, 실험 및 유한요소해석을 수행한 것이다. 경사각, 이음부깊이/높이 및 구속응력을 변수로 총 18개의 실험체에 대한 실험 및 유한요소해석결과 ,이음부의균열저항성 개선을 위해서는 경사각이 60。, D/H가 1/4일 경우가 유리하며 측방향구속으로 이음부를 압축상태로 유지하는 것이 이음부 균열방지에 효과적임을 알았다.