• 제목/요약/키워드: Protected facility

검색결과 58건 처리시간 0.021초

초등학교 복합화시설 모니터링 평가연구 - 서울시 초등학교를 중심으로 - (A Study on the Monitoring Evaluation of Elementary School Complex Facilities - Focusing on Elementary Schools in Seoul -)

  • 목정훈
    • 교육시설
    • /
    • 제16권5호
    • /
    • pp.3-10
    • /
    • 2009
  • The purpose of this study is to provide an remodification method for elementary school complex facilities in Seoul Metropolitan city. This study analyzes the questionnaire survey for 568 entire elementary schools and the questionnaire survey for school facility complex project operated 44 elementary schools. Then the result of this study was deduced from the comparison between the 568 entire survey data and 44 survey data in terms of the cognition of school facility complex project, the required type of facility and the problems of complex facility maintenance and operation. Four major findings were revealed as the result of research. First, there is a very high agreement with the school facility complex projects. Second, it was need that the process of planning and design was remodified to enhance participation of parents of students and local residents for selecting an appropriate complex facility. Third, education environment and student safety should be protected from any other school facility complex environments. Fourth, an agreement and regulation is needed for more effective maintenance and operation of school complex facilities.

Influences of Coatings and Solution Corrosivity on Cathodic Protection of Metallic Materials

  • Yoo, Y.R.;Chang, H.Y.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.106-111
    • /
    • 2006
  • Painting has protected metallic stack but the paint films may be degraded and corrosion problem can be arisen. To protect the painted metal stack, cathodic protection can be applied. If cathodic protection is applied to bare metal, only small area may be protected. However, if cathodic protection is applied to painted metal surface, large area can be protected and the lifetime of paint films can be extended. High corrosion resistant alloys were corroded at a Flue Gas Desulfurization (FGD) facility of power plant within a short period and thus cathodic protection can be used to protect these metals. On the base of computer simulation, if cathodic protection is applied to bare metal in a FGD environment, it was estimated that applied current could almost be spent to protect area near the anode. However, if cathodic protection is applied to high resistant-coated metal, the much larger area from the anode could be effectively protected.

충남지방의 시설채소 재배동향과 앞으로의 방향 (Suggestion for the Future of Protected Vegetable Crops Culture in Chungnam)

  • 이영복;강재철
    • 농업과학연구
    • /
    • 제17권1호
    • /
    • pp.18-25
    • /
    • 1990
  • The above results indicate that vegetable crop production using vinyl houses continously increases. However, technical support and facility improvement are still insufficent to establish a full production system. In order to improve the cultural environment in facilities for better vegetable culture, several facters should be considered. 1. Facility design and arrangement should be made to improve micro-environments for crop growth and development because direction of facility and covering materials can affect the amount of light trasmitted into vinyl houses. 2. Cultivation of several leading varieties in each crop may not provide stable production and profit especially under undesirable environmental conditions. Thus, it is required to grow not only leading varieties but also other cultivars to decrease the economic losses. 3. Crops should be carefully managed when planted in early season not to experience low temperatures which induce growth retards. Early season cultivation requires proper selection of cultivars which are resistant to low temperture. 4. Active control of micro-environment in facilities should be made via improving the ventilation and irrigation systems.

  • PDF

Development of Environmental Control System for High-Quality Shiitake Mushroom (Lentinus edodes (Berk.) Sing.) Production

  • Kwon, Jin-Kyung;Kim, Seung-Hee;Jeon, Jong-Gil;Kang, Youn-Ku;Jang, Kab-Yeol
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.342-351
    • /
    • 2018
  • Purpose: Recently, an increasing number of farms have been cultivating shiitake mushrooms using a sawdust substrate and a cooler/heater. In this study, an attempt was made to develop an environmental control system using a heat pump for cultivating high-quality shiitake mushrooms. Methods: An environmental control system, consisting of an air-to-water type heat pump, a thermal storage tank, and a radiator in a variable opening chamber, was designed and fabricated. The system was also installed in the cultivation facility of a farm cultivating shiitake mushrooms so as to compare the proposed control system with a conventional environmental control system using a cooler-condensing unit and an electric hot water boiler. Results: The uniformity of the environment was analyzed through environment measurements taken at several positions inside the cultivation facility. It was determined that the developed environmental control system is able to control the variations in temperature and relative humidity to within 1% and 3%, respectively. In addition, a maximum temperature difference of $30^{\circ}C$ (maximum of $35^{\circ}C$, minimum of $5^{\circ}C$) and a maximum relative humidity difference of 30% (maximum of 90%, minimum of 60%) can be attained within 30 min inside the cultivation facility through the cooling of the heat pump and heating of the radiator in a variable opening chamber. Thus, the developed control system can be used to cultivate high-quality shiitake mushrooms more effectively than a conventional cooler and heater. Conclusions: In comparison with a conventional environmental control system, the developed system decreased the yield of ordinary mushrooms by 65%, and increased that of high-quality mushrooms by 217%. This corresponds to a 16% increase in gross farm income. Consequently, the developed system is expected to improve the income of shiitake mushroom cultivating farms.

시설원예 배출 배액의 수질환경 평가 및 정화 부하량 산정 (The Water Quality and Purification Load Assessment of Drain Water of Facility Horticulture Areas)

  • 손진관;최덕규;공민재;윤성욱;박민정;강동현
    • 한국환경과학회지
    • /
    • 제28권12호
    • /
    • pp.1199-1208
    • /
    • 2019
  • Korea's protected horticulture is rapidly increasing in scale due to various advantages such as year-round harvesting, labor savings through automation and shortened culture period, and greater income generation. This study was conducted to investigate the impact of protected horticulture on water quality. The results of this study are expected to provide basic data contributing to improvements towards sustainable agriculture and eco-friendly design of protected horticulture complex. The average T-N and T-P loads from vinyl greenhouses were 286.55± 143.98 mg/L and 59.14±13.77 mg/L, respectively and those from glass greenhouses 380.68 ± 150.41 mg/L and 61.85±20.72 mg/L. The annual discharge of wastewater derived from the monthly discharge from the horticulture greenhouses were estimated at 2597 ton/ha, with the annual phosphorus load amounting to 155.3 kg/ha. The average T-N and T-P loads in the tested greenhouse effluents were in excess of 8.3- and 13.5-fold the standards for the Korean wastewater plant effluent. The waste nutrient solution discharged from a protected horticulture complex can cause water contamination. Therefore, there is a need to conduct follow-up research using a water purification system or a trench method to develop a eco-friendly protected horticulture complex for sustainable agriculture.

보호계전기 정보를 이용한 피보호 설비의 고장진단에 관한 연구 (A Study on the Fault Diagnoais of Protected Facility using Relay Information)

  • 이태영;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.151-153
    • /
    • 2002
  • This paper proposes a concept for fault diagnosis system based on the relay coordination to deal with unavoidable uncertainties imposed on fault dignosis of substation. This system uses information on the relay setting values and tripped data to identify the faulted element of power system. The proposed concept will be very useful and efficient for substation and control center operator.

  • PDF

단거리 지대공 미사일의 최적배치에 관한 연구 (A Study on Optimal Allocation of Short Surface-to-Air Missile)

  • 이영해;남상억
    • 한국국방경영분석학회지
    • /
    • 제26권1호
    • /
    • pp.34-46
    • /
    • 2000
  • The object of this study is to construct a model for an optimal allocation of short surface to air missile defending our targets most efficiently from hostile aircraft´s attack. For the purpose of this, we analyze and establish facility allocation concept of existing models, apply set covering theory appropriate to problem´s properties, present the process of calculating the probability of target being protected, apply Sherali-Kim´s branching variable selection strategy, and then construct the model. As constructed model apply the reducing problem with application, we confirm that we can apply the large scale, real problem.

  • PDF

독일 산업·기술문화재 한자 코크스 제조소 재생사례 분석 (Analysis on the Characteristics of the Precedents for Industrial/Technological Cultural Properties of the Hansa Coking Plant)

  • 김홍기;박창호
    • 한국가구학회지
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2016
  • The Industrial/Technological Cultural Properties are being protected, the rest facing with demolition and damages. In order to better cope with such situation, Korea has officially introduced the Registered Cultural Properties System since 2001 and began acknowledging the historical values of industrial buildings as modern cultural properties. In the Nordrhein-Westfalen, Germany, there are approximately 3,500 industrial buildings under the cultural asset protection and management not only in the Ruhr-region but also state-wide. Among these, this case study focuses on the Hansa Coking Plant, a large-scale Revitalization project to rehabilitate the old industrial complexes and facility buildings that have been shut down on December 15, 1992. Purpose of this study is to analyze main project plans of each facility in the Hansa Coking Plant and to bring out the main features of the plans, so that they can be utilized to find suggestions for Industrial/Technological Cultural Properties Revitalization in Korea.

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF