• 제목/요약/키워드: Protect coordination

검색결과 45건 처리시간 0.024초

배전계통에 초전도 전류계한기 적용 시 Recloser-Fuse 협조 분석 (Analysis of Recloser-Fuse Coordination in Distribution System with SFCL)

  • 김명후;김진석;유일경;문종필;임성훈;김재철;안재민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.432-435
    • /
    • 2009
  • This paper shows us the basic protective devices to protect against fault current such as recloser and fuse. Also recloser has been coordinated with fuse in distribution system to protect against fault current efficiently. However, in distribution system with SFCL, recloser-fuse coordination could be different to now and fault current couldn't be clear, if occurred. Therefore, this paper analysed recloser-fuse coordination in distribution system with SFCL using PSCAD/EMTDC

  • PDF

배전계통에 초전도 전류제한기 적용 시 Recloser-Fuse 협조 방법 (Method of Recloser-Fuse Coordination in Power Distribution System with SFCL)

  • 김명후;김진석;유일경;문종필;임성훈;김재철;안재민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.8_9
    • /
    • 2009
  • This paper shows us the analysis of the Recloser-Fuse coordination in power distribution system. Recloser has been installed with fuse to coordinate in power distribution system to protect against fault current efficiently. However, in power distribution system with SFCL, fault current couldn't be clear if occurred it as the operation of the Recloser-Fuse coordination couldn't be done. Therefore, this paper analysed the operation of the Recloser-Fuse coordination and found the method of the Recloser-Fuse coordination in power distribution system with SFCL using PSCAD/EMTDC.

  • PDF

배전계통에 연계된 열병합발전 시스템의 개선된 보호협조 방안에 관한 연구 (Advanced Protective Coordination Schemes of Utility Interconnected Cogeneration Systems)

  • 최준호;정성교;추동욱;김낙경;손학식;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.280-288
    • /
    • 2000
  • Recently, there has been growing interest in utilizing cogeneration(COGN) systems with a high-energy efficiency due to the increasing energy consumption and the lacking of energy resource. But an insertion of COGN system to existing power distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power of COGN, especially in protective coordination. A study on a proper coordination with existing one is being required. The existing power distribution system is operated with radial type by one source and protection system is composed based on unidirectional power source. But an Insertion of COGN system to power distribution system change existing unidirectional power source system to bidirectional power source. Therefore, investigation to cover whole field of power distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. In this paper, simulation using PSCAD/EMTDC was accomplished to analyze effect of COGIN on distribution fault current. Also, the existing protection system of 22.9[kV] power distribution system and customers protection system to protect of COGIN was analyzed and the study on protective coordination between of two protection system accomplished.

  • PDF

마이크로그리드 실증사이트의 보호협조 전략 (Protection Coordination Strategy of Microgrid Demonstration Site)

  • 진대근;최원준;원동준;이학주;채우규;박중성
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.966-973
    • /
    • 2012
  • In microgrid demonstration site, distributed generations can make bidirectional power flows on the system. If an accident occurs, the fault current from the inverter based distributed generation is small. However, the conventional protection scheme in distribution network is designed to operate at high fault current. This means that the traditional protection of distribution network is no longer applicable and new protection methods must be developed. In this paper, for two cases, algorithms for protection coordination of demonstration site is proposed and verified through PSCAD/EMTDC simulation. In first case, protection devices are assumed to have the abilities of directional relaying and communication. In second case, protection devices do not have those abilities. Proposed protection coordination algorithms detect the fault locations and protect the microgrid fairly well.

적응진화연산을 이용한 배전계통의 과전류계전기 최적 정정치 결정 (Optimal Setting of Overcurrent Relay in Distribution Systems Using Adaptive Evolutionary Algorithm)

  • 정희명;이화석;박준호
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1521-1526
    • /
    • 2007
  • This paper presents the application of Adaptive Evolutionary Algorithm (AEA) to search an optimal setting of overcurrent relay coordination to protect ring distribution systems. The AEA takes the merits of both a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner to use the global search capability of GA and the local search capability of ES. The overcurrent relay settings and coordination requirements are formulated into a set of constraint equations and an objective function is developed to manage the overcurrent relay settings by the Time Coordination Method. The domain of overcurrent relays coordination for the ring-fed distribution systems is a non-linear system with a lot of local optimum points and a highly constrained optimization problem. Thus conventional methods fail in searching for the global optimum. AEA is employed to search for the optimum relay settings with maximum satisfaction of coordination constraints. The simulation results show that the proposed method can optimize the overcurrent relay settings, reduce relay mis-coordinated operations, and find better optimal overcurrent relay settings than the present available methods.

전력계통에서의 과전류계전기 보호협조에 관한 연구 (A Study on the Overcurrent Relay Coordination in Power Systems)

  • 최홍규;김경철;오정석;김병철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF

연안습지의 효율적 관리를 위한 Mitigation 개념의 한국적 적용방안에 관한 연구 -법제도 개선방안을 중심으로- (A Study on the Application of the Mitigation System for Efficient Management of Coastal Wetlands in Korea -Enhancement of Legal Regime-)

  • 박성욱;권문상;이용희;이미진
    • Ocean and Polar Research
    • /
    • 제25권4호
    • /
    • pp.545-555
    • /
    • 2003
  • It is widely known that compare to many other countries, the U.S.A. has a strong framework for efficient implementation of mitigation policy to protect wetlands. As indicated in many strong mitigation initiatives, mitigation policy primary requires avoidance rule for wetland damage and if a developer inevitability damages wetlands, the development should be minimize, and as a last resort, the policy impose legal duty that a developer should compensate wetland corresponding to the damaged wetlands. However, the legal system fur Korea's mitigation system does not provide any legal duty for the compensatory mitigation, although the possibility of creation of tidal flat is casually expressed in several Korean legal systems. Therefore, without any strong and enforceable legal system, Korean mitigation system cannot efficiently protect Korea's vast and productive wetlands. To introduce mitigation policy similar to the U.S.A. in Korea, we suggest that there (a) should be a strongly policy which regulate legal duty for the compensatory mitigation, (b) should be an improve management system for actively corresponding to special knowledge relating to environment, and lastly, (c) should be a system which consider a class action introduced in environmental regime for a long term protection of tidal wetlands for future generation.

소형 열병합발전 시스템이 연계된 배전계통에 초전도 전류제한기 적용시 리클로져-퓨즈 협조 분석 (Analysis on Recloser-Fuse Coordination in a Power Distribution System linked Small Scale Cogeneration System with Superconducting Fault Current Limiter)

  • 김명후;김진석;문종필;임성훈;김재철;이준규
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.499-505
    • /
    • 2010
  • This paper analyzed that the coordination of recloser-fuse when a superconducting fault current limiter (SFCL) is installed to a power distribution system linked small scale cogeneration system. As a rule, the recloser to properly protect against both permanent and temporary fault is installed to upstream of fuse. Therefore, in a power distribution system linked small scale cogeneration system, the fault current is increased by adding fault current of small scale Cogeneration system when a permanent fault occurs, and the fuse could melt during the first fast operation of the recloser because of more sufficient heat from the increased current. However, when SFCLs are applied into a power distribution system linked small scale cogeneration system, the coordination of recloser-fuse could be accomplished due to decreased fault current as the effect of the impedance value of the SFCL. Therefore, to solve these problems, we analysed the operation of recloser-fuse coordination in a power distribution system linked small scale cogeneration system with SFCL using PSCAD/EMTDC.

발전기 과여자 및 과전압 계전기 보호협조에 관한 연구 (A Study on the Protective Coordination of Generator Overexcitation and Overvoltage Relay)

  • 박지경;김광현;김철환;유영식;양정재
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1187-1194
    • /
    • 2017
  • After North American wide area black out on August 14, 2003, various studies have been conducted to find out the reason of the disaster. One of main reasons was misoperation of generator protection system. Since then, protective coordination between generator protection system and excitation system controls has been hot issue among electrical engineers. Among various generator protection relays, in this paper, we focused on generator overvoltage and overexcitation relay, which protect the over-flux condition of the generator. Thus, at first, we modeled the generator overvoltage, overexcitation relay and detailed power system including excitation system, governor and etc., based on actual field data. And then, we reviewed the protective coordination of generator overvoltage and overexcitation relay using electromagnetic transient program. In addition, we discussed the protective coordination method for redundant protection relays in both automatic voltage regulator and generator side.

배전계통에 초전도 전류제한기 적용 시 Relcoser-Fuse 협조 방법에 관한 연구 (A Study of Re-Fuse Coordination Method of Distribution System with SFCL)

  • 김명후;김진석;유일경;문종필;임성훈;김재철
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1835-1841
    • /
    • 2009
  • We analyze the problem of recloser-fuse coordination when a superconducting fault current limiter (SFCL) is installed to a power distribution system. Generally, The recloser is installed to upstream of fuse to protect against both permanent fault and temporary one appropriately. However, in a power distribution system with SFCL, the fault current is decreased by the effect of the impedance value of the SFCL and when a permanent fault occurs, the fuse may not melt during the last delay operation of the recloser because of the insufficient heat from the decreased current. Therefore, when SFCLs are applied into a power distribution system, the rating of the fuse has to be reselected to coordinate recloser to fuse effectively. To solve these problems, this paper analysed the operation of recloser-fuse coordination and presented the improved recloser-fuse coordination method in a power distribution system with SFCL using PSCAD/EMTDC.