• Title/Summary/Keyword: Prosthesis type

Search Result 250, Processing Time 0.027 seconds

Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption (임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료)

  • Choi, Yu-Sung
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

Design of the Speech Signal Processores for Cochlear Prosthesis (청각 보철용 음성신호 처리기의 설계)

  • Park, Sang-Hui;Choi, Doo-Il;Beack, Seung-Wha
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.285-294
    • /
    • 1991
  • Two types of the speech signal processores (SSP) for the cochlear a prosthesis are designed. One is designed using the cochlear model and the other is designed using the information (formant, pitch, intensity) extraction method. For these, some cochlear model and acoustic information extraction method are proposed. The result shows the SSP of the cochlear model type contain more acoustic cues than that of information extraction type. On the other hand, stimulus signal is clear and algorithm is simple in the SSP of the information ex traction type.

  • PDF

Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot (설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향)

  • Kim, Tae-Kyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.206-211
    • /
    • 2018
  • Purpose: Recently, a method of forming a slot in the prosthesis lingual has been introduced to solve the occlusal and aesthetic disadvantages of screw-retained prosthesis in the manufacture of implant-fixed prosthesis and to ensure retrievability in cement retained prostheses. The purpose of this study is to investigate the effect of the internal gap on the removal of the prosthesis in the preparation of cement-retained implant prostheses with lingual slots. Materials and methods: Titanium abutment and internal gap of the zirconia prosthesis to be attached to the upper part were set to 30, 35, and $50{\mu}m$, respectively. Three for each type total 15 were produced for each type. The zirconia prosthesis formed a retrievable cement-type slot with a space of 1 mm at the location where the titanium abutment meets the shelf area. Autocatalytic resin cement was used for bonding of abutment and zirconia prosthesis, and the maximum removal stress value was measured in units of Ncm by using the customized equipment of the cemented specimen. The Kruskal-Wallis test was used to compare the three groups by statistical analysis (${\alpha}=.05$), modified by post hoc test the Mann-Whitney U-test and the Bonferroni correction method were used to compare the two methods (${\alpha}=.017$). Results: There was no statistically significant difference in removal stress between the $30{\mu}m$ group and the $35{\mu}m$ group in the internal gap (P = .032), and there was a significant difference between the $30{\mu}m$ group and the $50{\mu}m$ group, between the $35{\mu}m$ group and the $50{\mu}m$ group (P < .017). Conclusion: Thus, the internal gap of computer-aided design affected the retention between the zirconia prosthesis and the titanium abutment.

Mechanical versus Tissue Aortic Prosthesis in Sexagenarians: Comparison of Hemodynamic and Clinical Outcomes

  • Son, Jongbae;Cho, Yang Hyun;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.100-108
    • /
    • 2018
  • Background: The question of which type of prosthetic aortic valve leads to the best outcomes in patients in their 60s remains controversial. We examined the hemodynamic and clinical outcomes of aortic valve replacement in sexagenarians according to the type of prosthesis. Methods: We retrospectively reviewed 270 patients in their 60s who underwent first-time aortic valve replacement from 1995 to 2011. Early and late mortality, major adverse valve-related events, anticoagulation-related events, and hemodynamic outcomes were assessed. The mean follow-up duration was $58.7{\pm}44.0$ months. Results: Of the 270 patients, 93 had a mechanical prosthesis (mechanical group), and 177 had a bioprosthesis (tissue group). The tissue group had a higher mean age and prevalence of preoperative stroke than the mechanical group. The groups had no differences in the aortic valve mean pressure gradient (AVMPG) or the left ventricular mass index (LVMI) at 5 years after surgery. In a sub-analysis limited to prostheses in the supra-annular position, the AVMPG was higher in the tissue group, but the LVMI was still not significantly different. There was no early mortality. The 10-year survival rate was 83% in the mechanical group and 90% in the tissue group. The type of aortic prosthesis did not influence overall mortality, cardiac mortality, or major adverse valve-related events. Anticoagulation-related events were more common in the mechanical group than in the tissue group (p=0.034; hazard ratio, 4.100; 95% confidence interval, 1.111-15.132). Conclusion: The type of aortic prosthesis was not associated with hemodynamic or clinical outcomes, except for anticoagulation-related events.

Grip Force Control of Myoelectric Signal Driving Type Myoelectric Hand Prosthesis (근전위 신호구동형 전동의수의 파지력 제어)

  • Choi, Gi-Won;Choe, Gyu-Ha;Shin, Woo-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.340-342
    • /
    • 2007
  • This paper presents the grip force control of myoelectric hand prosthesis according to myoelectric signal generated in the human muscle. The control system consist of a controller for driving DC motor, torque sensor for measuring out torque of motor, slip sensor for detecting slip of torque. The experimental results proved the reliability of proposed control system.

  • PDF

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

Tracheoesophageal Shunt Voice in Total Laryngectomee (후두 전 절제 환자에서 음성재활을 위한 기관식도발성)

  • Wang, Soo-Geun;Jang, Sun-Mi
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • Total laryngectomy is the most useful procedure tor advanced laryngopharyngeal cancer, but it remains the major problem such as loss of voice. Voice restoration is essential for every patients who undergo a total laryngectomy. Ideal voice rehabilitation methods can resolve three factors. First, every laryngectomee can produce voice sufficient for communication, second every patient should be allowed to use both hands freely during phonation, and last, the voice restoration methods should be easy and safe without complication during and after treatment. Among various voice rehabilitation procedures during or after total laryngectomy, it can be divided electronic and pneumatic methods. In pneumatic methods, there are also divided both pulmonary air and non-pulmonary air methods. The non-pulmonary air methods include esophageal speech, buccal speech, and pharyngeal speech. Pulmonary air methods are divided into surgical and non-surgical such as pneumatic speech aid. In the surgical methods, there are neoglottic operation, tracheopharyngeal shunt, and tracheopharyngeal shunt operations. Recently, tracheoesophageal shunt with or without prosthesis are being recognized the most effective method. Blom-Singer low pressure prosthesis, Panje button, and Provox are well known types of prosthesis in the tracheoesophageal shunt operation. Amatsu method is a kind of famous tracheoesophageal shunt method without using prosthesis. Authors tried to review the published articles for evaluation of effectiveness and problems of tracheoesophageal shunt operation with or without prosthesis. In conclusion, indwelling type of prosthesis and pharyngeal myotomy and plexus neurectomy are recommended for higher success rate during tracheoesophageal puncture procedure. More over, Amatsu method is also one of the recommended voice rehabilitation procedure during total laryngectomy. In this situation, pharyngeal myotomy and plexus neurectomy may be helpful for better fluent communication.

  • PDF

Effects of cementless fixation of implant prosthesis: A finite element study

  • Lee, Hyeonjong;Park, Soyeon;Kwon, Kung-Rock;Noh, Gunwoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.341-349
    • /
    • 2019
  • PURPOSE. A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS. The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS. Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 ㎛ at the abutment-resin interface and 24.4 to 24.7 ㎛ at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION. CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis.

Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report (완전 무치악 환자에서 자유 착탈가능 임플란트 지대주를 이용한 임플란트 융합 국소의치 수복증례)

  • Oh, You-Kyoung;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeon-Jong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.