• 제목/요약/키워드: Prosthesis type

검색결과 252건 처리시간 0.029초

A retrospective study on related factors affecting the survival rate of dental implants

  • Jang, Hee-Won;Kang, Jeong-Kyung;Lee, Ki;Lee, Yong-Sang;Park, Pil-Kyoo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.204-215
    • /
    • 2011
  • PURPOSE. The aim of this retrospective study is to analyze the relationship between local factors and survival rate of dental implant which had been installed and restored in Seoul Veterans Hospital dental center for past 10 years. And when the relationship is found out, it could be helpful to predict the prognosis of dental implants. MATERIALS AND METHODS. A retrospective study of patients receiving root-shaped screw-type dental implants placed from January 2000 to December 2009 was conducted. 6385 implants were placed in 3755 patients. The following data were collected from the dental records and radiographs: patient's age, gender, implant type and surface, length, diameter, location of implant placement, bone quality, prosthesis type. The correlations between these data and survival rate were analyzed. Statistical analysis was performed with the use of Kaplan-Meier analysis, Chi-square test and odds ratio. RESULTS. In all, 6385 implants were placed in 3755 patients (3120 male, 635 female; mean age $65{\pm}10.58$ years). 108 implants failed and the cumulative survival rate was 96.33%. There were significant differences in age, implant type and surface, length, location and prosthesis type (P<.05). No significant differences were found in relation to the following factors: gender, diameter and bone quality (P>.05). CONCLUSION. Related factors such as age, implant type, length, location and prosthesis type had a significant effect on the implant survival.

PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화 (Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image)

  • 한상현
    • 한국융합학회논문지
    • /
    • 제9권9호
    • /
    • pp.117-122
    • /
    • 2018
  • 본 연구는 PET-CT 검사를 시행할 때 치과보철물에 의해 발생되는 CT의 HU(Hounsfield Unit) 값을 금속의 종류에 따라 측정하고, PET 영상의 왜곡정도와 표준섭취계수(SUV)의 변화를 확인하여 영상 판독 시 오류의 감소방안을 제시하고자 하였다. 실험방법은 실제 치아와 메탈 크라운, 골드크라운, 티타늄, 지르코니아의 치과보철물을 이용하여 PET-CT 검사를 실시하였다. 일반 치아와 비교한 결과 HU 값이 증가함에 따라 SUV 값이 증가되는 것을 확인하였고, 메탈 크라운, 티타늄, 지르코니아의 SUV 값은 37% 정도 증가되었고, 골드 크라운에서는 45.4%로 가장 많이 증가했다. 그리고 일반치아, 메탈크라운, 티타늄, 지르코니아에서 영상 왜곡은 미미했지만, 골드 크라운에서는 선속경화현상이 심하게 발생하였고, 영상 왜곡이 나타났다. 따라서 치과보철물의 금속종류는 SUV 값에 영향을 미치기 때문에 치과 보철물 중에서 골드 재질을 사용한 환자를 진단할 때에는 영상 판독 시 보정된 PET 영상보다는 NAC(무보정) PET 영상을 확인한다면 판독에 도움을 줄 수 있을 것으로 생각된다.

고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례 (Full mouth rehabilitation of edentulous patient with fixed implant prosthesis)

  • 신희현;김종진;백진;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제37권3호
    • /
    • pp.147-156
    • /
    • 2021
  • 완전 무치악 환자의 구강 회복은 통상적 총의치, 하이브리드 보철물, 임플란트 지지 고정성 보철물 등 다양한 치료 옵션을 통해 이루어질 수 있다. 전악 임플란트 고정성 보철 수복의 경우 가철성 수복과 비교해 최종적인 보철물의 형태를 고려하여 정확한 위치에 임플란트를 식립해야 한다는 어려움이 따른다. 본 증례에서는 치아우식과 만성 치주염으로 전악 발거를 요하는 환자의 전악 임플란트 고정성 수복을 진행하였다. 임플란트 식립 단계에서 최종 보철물 형태를 고려하여 제작된 수술용 가이드를 이용하여 원하는 위치에 임플란트를 식립 하였으며 고정성 임시 수복물 단계에서 수정 및 재제작을 통해 기능과 심미를 평가하였다. 이렇게 제작된 임시 수복물을 바탕으로 금속 도재관의 최종 수복물을 장착하였다. 나사 풀림 및 도재 파절 등의 합병증에 대처하기 위해 구치부의 경우 나사 유지형 보철물, 전치부는 나사 시멘트 유지형 보철물로 제작하였다. 그 결과 환자는 최종 보철물 장착 후 기능적 심미적 측면에서 개선된 예후를 보였다.

개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례 (Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system))

  • 홍태영;김만용;윤준호
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.423-430
    • /
    • 2016
  • 임플란트 보철물은 나사 유지형 보철물과 시멘트 유지형 보철물로 나눌 수 있다. 각 방법은 장점과 함께 임플란트를 유지 관리하는데 불리한 단점을 가지고 있다. 이러한 단점을 극복하기 위해 개선된 설측 고정 나사 시스템(T-screw system)이 개발되었다. T-screw system은 설측 방향의 나사를 이용하여 임플란트 보철물을 유지하는 방법으로, 보철물의 탈부착이 쉽고, 수동적 적합이 가능하며, 심미적이고 기능적인 교합면을 형성할 수 있다는 장점이 있다. 기존의 수평 나사를 이용한 보철은 기공 과정이 어려워 다수 유닛의 보철물의 경우 제작이 쉽지 않았고, 완전 도재를 이용한 보철물에서는 사용할 수 없다는 한계를 가지고 있었다. 본 증례에서 T-screw system을 이용하여 임플란트 보철물을 제작함으로써 유지 관리가 용이하고 심미적, 기능적으로 우수한 결과를 얻었다. 또한 다수 유닛의 임플란트 보철 및 완전 도재를 이용한 임플란트 보철에서 T-screw system을 이용하는 방법을 보고하고자 한다.

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

혀절제술을 시행한 환자의 보철적 수복 증례 (Prosthetic rehabilitation for a glossectomy patient - a clinical report)

  • 윤지영;이시호;이지연;오남식
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.347-352
    • /
    • 2013
  • 혀는 정확한 근신경계의 조화에 의해 저작, 연하, 발음과 같은 복잡한 기능을 수행하는 데 중요한 역할을 한다. 악성종양으로 인해 구강 내 혀를 절제해야 하는 경우에 환자는 발음 및 연하에 큰 어려움을 겪게 된다. 이러한 환자에 있어 보철적 치료 목표는 저작, 연하 및 발음을 증진시키는 것이다. 보철적 수복 방법은 수술의 종류 및 범위에 의해 결정된다. 완전 혀 절제술(Total glossectomy)을 시행한 경우에는 하악-혀장치(mandibular tongue prosthesis)를 선택하며 악-혀장치(Mandibular tongue prosthesis)는 혀 보철물로 구강저를 채우는 것이다. 이렇게 형성한 혀 보철물은 음식이 식도로 넘어가는 입구(platform)를 형성해주고 발음을 향상시키며 하방의 연약한 이식 조직을 보호하고 외형 및 심리사회적으로 우수하다는 장점을 가진다. 본 증례에서는 완전 혀 절제술(total glossectomy)를 시행한 환자를 위해 보철적으로 수복하는 임상과정을 논의하고자 한다.

인체 중이 임플란트 개발에 관한 연구 (A Study on the Development of a Human Middle Ear Implant)

  • 유승현;김학균;김종범;송준호;오대진
    • 한국CDE학회논문집
    • /
    • 제14권2호
    • /
    • pp.87-95
    • /
    • 2009
  • This paper describes the design of the ossicular replacement prosthesis for the people who have problem of hearing because of middle ear disease. Also the simulation results of the designed product for verification by finite element analysis software (ABAQUS) are presented. New model is applied to middle ear FE analysis which was generated in previous study. The full replacements of ossicular prosthesis for ossicles (malleus, incus and stapes) are made of Hydroxyapatite and Titanium. Although other existing prosthesis models consider only sound amplification effect, current type has damper system which is operating on the audible frequencies. High frequency sound transmitted to inner ear can be reduced and the prosthesis and inner ear can be prevented from damage.

치과보철물 재료의 마멸특성 (Wear Characteristics of Dental Prosthesis)

  • 최원식;김원구
    • 한국기계가공학회지
    • /
    • 제7권3호
    • /
    • pp.110-114
    • /
    • 2008
  • In this study, to examine the friction coefficient and wear amount of dental prosthesis, pin-on-disk type wear test were at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by SEM. The friction coefficient of dental material was investigated according to weight and slinging velocity. dental material have investigated composed to nature teeth.

  • PDF

'The design concepts of Kudo Total Elbow Prosthesis, and some of the technical considerations for its use'

  • Kudo Hiroshi
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2002년도 아시아견관절학술대회
    • /
    • pp.177-179
    • /
    • 2002
  • Total elbow prostheses which are now available in clinical use can generally be classified into two major categories ; one bing linked prostheses, another being unlinked prostheses. Of those two categories I am dealing here only with the problems of the unlinked type prosthesis, particularly with those of non-constrained, surface-replacement prostheses. Furthermore, my presentations this time may have to be narrowed down only to the topics regrading the particular features and some of the technical problems with Kudo Elbow Prosthesis, due to the time limit assigned for this presentation.

  • PDF