• Title/Summary/Keyword: Prosthesis failure

Search Result 162, Processing Time 0.038 seconds

A STUDY OF THE MICROLEAKAGE AT THE POST AND CORE AND TOOTH INTERFACE (포스트 코아와 치근 계면에서의 미세누출에 관한 연구)

  • Shin, Ji-Cheol;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.366-378
    • /
    • 1998
  • Post and core is used to restore endodontically treated teeth, and it is a very important part which supplies retention and support to the prosthesis. But occasionally, caries occured due to the microleakage at the post and core and tooth interface, the failure of prosthesis has happened. In this study, the microleakage of cast gold post and core, amalgam core, and composite resin core was investigated and compared. The coronal part of the extracted upper anterior teeth were removed and endodontically treated with conventional method. The teeth were divided into three groups. In group 1, cast gold post and core was cemented with resin cement and in group 2, ready-made post was cemented with resin cement and amalgam core was built. In group 3, ready-made post was cemented with resin cement and composite resin core was built. All specimens were thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ with dwell time of 15 seconds, and immersed in 0.5% aqueous solution of basic fuchsin dye for 24 hours. After embedded in the epoxy resin, the specimens were sectioned longitudinally and observed with stereomicroscope with the magnification of 25. From the findings of this study, the following conclusions were obtained. 1. There was microleakage at the core/tooth interface of all specimens. 2. The microleakage of gold post and core was significantly less than those of the other two groups. 3. There was no significant difference between the microleakage of amalgam core and that of composite resin core.

  • PDF

Implant-assisted removable partial denture for severely atrophied mandible (심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례)

  • Choi, Bada;Kim, Yeun Ju;Lee, Jae Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.171-175
    • /
    • 2019
  • Mandible with severe alveolar bone atrophy poses a significant challenge in terms of reproducing clinically acceptable anatomy for a removable prosthesis. To overcome this potential complication, altered cast impression technique is often recommended to capture accurate and functional gingiva tissues. It becomes possible to get proper anchors functional impression by placing 2 implants crowns which were impossible in previous implant overdenture impression technique. In this case, an 80-year old female patient with severe mandibular ridge atrophy was treated with an implant-assisted removable partial denture with two implant crowns on the canine area. An altered cast impression was taken with an individual tray on a metal framework of removable partial denture on both posterior edentulous areas. The patient was satisfied with the final prosthesis after failure of 2 previous prostheses. Clinician had a difficult time to manage disabled patient and patient were suffered with ill-fitting denture due to inaccurate impression in conventional overdenture condition. The oral rehabilitation was completed with placing 2 implants as proper anchor.

Definitive Closure of the Tracheoesophageal Puncture Site after Oncologic Laryngectomy: A Systematic Review and Meta-Analysis

  • Escandon, Joseph M.;Mohammad, Arbab;Mathews, Saumya;Bustos, Valeria P.;Santamaria, Eric;Ciudad, Pedro;Chen, Hung-Chi;Langstein, Howard N.;Manrique, Oscar J.
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.617-632
    • /
    • 2022
  • Tracheoesophageal puncture (TEP) and voice prosthesis insertion following laryngectomy may fail to form an adequate seal. When spontaneous closure of the fistula tract does not occur after conservative measures, surgical closure is required. The purpose of this study was to summarize the available evidence on surgical methods for TEP site closure. A comprehensive search across PubMed, Web of Science, SCOPUS, and Cochrane was performed to identify studies describing surgical techniques, outcomes, and complications for TEP closure. We evaluated the rate of unsuccessful TEP closure after surgical management. A meta-analysis with a random-effect method was performed. Thirty-four studies reporting on 144 patients satisfied inclusion criteria. The overall incidence of an unsuccessful TEP surgical closure was 6% (95% confidence interval [CI] 1-13%). Subgroup analysis showed an unsuccessful TEP closure rate for silicone button of 8% (95% CI < 1-43%), 7% (95% CI < 1-34%) for dermal graft interposition, < 1% (95% CI < 1-37%) for radial forearm free flap, < 1% (95% CI < 1-52%) for ligation of the fistula, 17% (95% CI < 1-64%) for interposition of a deltopectoral flap, 9% (95% CI < 1-28%) for primary closure, and 2% (95% CI < 1-20%) for interposition of a sternocleidomastoid muscle flap. Critical assessment of the reconstructive modality should take into consideration previous history of surgery or radiotherapy. Nonirradiated fields and small defects may benefit from fistula excision and tracheal and esophageal multilayer closure. In cases of previous radiotherapy, local flaps or free tissue transfer yield high successful TEP closure rates. Depending on the defect size, sternocleidomastoid muscle flap or fasciocutaneous free flaps are optimal alternatives.

Clinical and Functional Outcomes of the Exeter V40 Short Stem in Primary and Revision Arthroplasty: Does the Indication Affect Outcomes in the Short Term?

  • Nemandra Amir Sandiford;Scott M. Bolam;Irrum Afzal;Sarkhell Radha
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.40-46
    • /
    • 2023
  • Purpose: A variety of short Exeter stems designed specifically for use in performance of total hip arthroplasty (THA) in primary and revision settings have recently been introduced. Some have been used 'off label' for hip reconstruction. The aim of this study is to report clinical and radiological results from the Exeter V40 125 mm stem in performance of primary THA and revision THA. Materials and Methods: This study had a retrospective design. Insertion of 58 (24 primary, 34 revision) Exeter V40 125 mm stems was performed between 2015 and 2017. The minimum follow-up period was two years. Assessment of the Oxford hip score (OHS), EuroQol-5 Dimension (EQ-5D), and radiological follow-up was performed at one and two years. Results: In the primary group, the preoperative, mean OHS was 13.29. The mean OHS was 32.86 and 23.39 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were at 0.14, 0.59, and 0.35, preoperatively, at one-year follow-up and two-year follow-up, respectively. In the revision group, the mean preoperative OHS was 19.41. The mean OHS was 30.55 and 26.05 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were 0.33, 0.61, and 0.48 preoperatively, at one-year follow-up and two-year follow-up, respectively. No progressive or new radiolucent lines were observed around any stem at the time of the final follow-up in all patients in both groups. Conclusion: Encouraging results regarding use of Exeter V40 125 mm stems have been reported up to two years following surgery in primary and revision THA settings.

Central Vein Occlusion Secondary to Hemodialysis Catheterization in Chronic Renal Failure Patient -One Case Report- (만성 신부전 환자에서 혈액투석 도관에 의한 중심정맥 폐쇄증의 수술치험 -1례 보고-)

  • Lee, Seock-Yeol;Lee, Jun-Bock;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.619-623
    • /
    • 1998
  • A 51-year-old male with chronic renal failure had marked swelling and tenderness of the right arm. Venography revealed central vein occlusion involving stenosis of right proximal subclavian vein, right internal jugular vein, and left distal innominate vein, and obstruction of right brachiocephalic vein. Multiple obstruction of these veins was thought to have resulted from repeated subclavian catheterization. Right subclavian-superior vena cava was bypassed with 10 mm Gore-tex vascular graft and then left subclavian vein with 8 mm Gore-tex vascular graft was bypassed to the 10 mm Gore-tex vascular graft. The results were excellent.

  • PDF

Early Failure of the Shelhigh Pulmonary Valve Conduit in Ross Operation - Two case reports- (Ross 수술시 사용한 Shelhigh 폐동맥판 도관의 조기 실패 -2예 보고-)

  • Jang Woo Sung;Kim Dong Jung;Kim Jin Hyun;Han Kook Nam;Choi Chang Hyu;Kim Woong Han
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.382-384
    • /
    • 2005
  • Background: It is very difficult to choose the ideal valved conduit used in right ventricle outflow reconstruction in child. We can use the cryopreserved homograft but there is a limit of application because of its difficulties in the size matching and supply capacity. The $Shelhigh^{(R)}$porcine-valved conduit is commercially available and used as an alternative choice in these days. We report two cases of early Shelhigh conduit failure in right ventricular outflow tract after Ross operation in congenital aortic stenosis.

The Dome Technique for Managing Massive Anterosuperior Medial Acetabular Bone Loss in Revision Total Hip Arthroplasty: Short-Term Outcomes

  • Tyler J. Humphrey;Colin M. Baker;Paul M. Courtney;Wayne G. Paprosky;Hany S. Bedair;Neil P. Sheth;Christopher M. Melnic
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.122-132
    • /
    • 2023
  • Purpose: The dome technique is a technique used in performance of revision total hip arthroplasty (THA) involving intraoperative joining of two porous metal acetabular augments to fill a massive anterosuperior medial acetabular bone defect. While excellent outcomes were achieved using this surgical technique in a series of three cases, short-term results have not been reported. We hypothesized that excellent short-term clinical and patient reported outcomes could be achieved with use of the dome technique. Materials and Methods: A multicenter case series was conducted for evaluation of patients who underwent revision THA using the dome technique for management of Paprosky 3B anterosuperior medial acetabular bone loss from 2013-2019 with a minimum clinical follow-up period of two years. Twelve cases in 12 patients were identified. Baseline demographics, intraoperative variables, surgical outcomes, and patient reported outcomes were acquired. Results: The implant survivorship was 91% with component failure requiring re-revision in only one patient at a mean follow-up period of 36.2 months (range, 24-72 months). Three patients (25.0%) experienced complications, including re-revision for component failure, inter-prosthetic dual-mobility dissociation, and periprosthetic joint infection. Of seven patients who completed the HOOS, JR (hip disability and osteoarthritis outcome score, joint replacement) survey, five patients showed improvement. Conclusion: Excellent outcomes can be achieved using the dome technique for management of massive anterosuperior medial acetabular defects in revision THA with survivorship of 91% at a mean follow-up period of three years. Conduct of future studies will be required in order to evaluate mid- to long-term outcomes for this technique.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Reverse Total Shoulder Arthroplasty: Where we are? "Principles" (견관절 역행성 인공관절 치환술의 원칙)

  • Noh, Kyu-Cheol;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2011
  • Purpose: The purpose of this article is to identify and understand the complications of RTSA and to review the current methods of preventing and treating this malady. Materials and Methods: Previous constrained prostheses (ball-and-socket or reverse ball-and-socket designs) have failed because their center of rotation remained lateral to the scapula, which has limited of the motion of the prostheses and produced excessive torque on the glenoid component, and this leads to early loosening. The Grammont reverse prosthesis imposes a new biomechanical environment for the deltoid muscle to act, thus allowing it to compensate for the deficient rotator cuff muscles. Results: The clinical experience does live up to the lofty biomechanical concept and expectations: the reverse prosthesis restores active elevation above $90^{\circ}$ in patients with a cuff-deficient shoulder. However, external rotation often remains limited and particularly in patients with an absent or fat-infiltrated teres minor. Internal rotation is also rarely restored after a reverse prosthesis. Failure to restore sufficient tension in the deltoid may result in prosthetic instability. Conclusion: Finally, surgeons must be aware that the results are less predictable and the complication/revision rates are higher in revision surgery than that in the first surgery. A standardized monitoring tool that has clear definitions and assessment instructions is surely needed to document and then prevent complications after revision surgery.