• Title/Summary/Keyword: Proportional resonant

Search Result 109, Processing Time 0.034 seconds

Control Strategy of MMC-HVDC under Unbalanced Grid Voltage Conditions

  • Zhang, Jianpo;Zhao, Chengyong
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1499-1507
    • /
    • 2015
  • High voltage direct current transmission based on modular multilevel converter (MMC-HVDC) is one of the most promising power transmission technologies. In this study, the mathematical characteristics of MMC-HVDC are analyzed in a synchronous rotational reference frame. A hybrid current vector controller based on proportional integer plus resonant is used to uniformly control the DC and double-base frequency AC currents under unbalanced grid voltage conditions. A corresponding voltage dependent current order limiter is then designed to solve the overcurrent problems that may occur. Moreover, the circulating current sequence components are thoroughly examined and controlled using a developed circulating current suppressor. Simulation results verify the correctness and effectiveness of the proposed control schemes.

Electromagnetic Modeling of Quasi-Square Open Metallic Ring Frequency Selective Surface Using Wave Concept Iterative Procedure

  • Titaouine, Mohammed;Raveu, Nathalie;Neto, Alfredo Gomes;Baudrand, Henri
    • ETRI Journal
    • /
    • v.31 no.1
    • /
    • pp.77-79
    • /
    • 2009
  • The wave concept iterative procedure (WCIP) is used to analyze a quasi-square open metallic ring frequency selective surface (FSS). The quasi-square open metallic ring FSS is dual-polarized. When the incident plane wave is polarized in a direction parallel to the FSS' coupled parallel strips, it shows two rejecting bands. Moreover, another rejecting band can be obtained if the source plane wave is perpendicularly polarized with respect to the FSS' coupled parallel strips. The three resonant frequencies are inversely proportional to the length of the FSS' coupled strips to provide an easy fine tuning of the FSS structure. The simulated results obtained using WCIP are compared to the measured results, and a good agreement is reported.

  • PDF

A Study on the Measurement of Dynamic Properties of the Rubber Mount in the Impeller Fan Motor of the Air-conditioner (에어컨 실내기 팬 모터용 방진고무의 동특성 측정에 관한 연구)

  • Choi, Hyun;Kim, Jun-Woo;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.185-190
    • /
    • 2001
  • The structure borne noise of the air-conditioner, which degrades the noise quality, is hardly reduced by the general noise treatments. It can be effectively reduced by eliminating the structural vibration which the noise originates from. The rubber vibration isolator prevents the dynamic force induced by the fan driving motor from exciting the chassis structure, which finally reduces the structure borne noise. The dynamic properties of the vibration isolation system such as the natural frequency of the vibration isolation and loss factor of the rubber isolator, need to be experimentally evaluated. In this paper, these dynamic properties were obtained by the resonant method using the impact hammer for 3 types of the isolator specimens. It is known that the isolation natural frequency of the axial direction of the rubber isolator is two times higher than that of the radial direction, and is proportional to the hardness of the rubber specimen.

  • PDF

Analysis of Current Controllers of Grid-connected PCS for Distributed Resource (분산전원용 계통연계형 PCS의 전류제어기 해석)

  • Jo, Teak-Hyun;Park, Jong-Hyeong;Kim, Heung-Geun;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.393-394
    • /
    • 2010
  • 본 논문은 LCL필터를 이용한 분산전원용 계통연계형 PCS의 전류제어기를 비교 분석하였다. 주요 비교대상은 PI(Proporional-intergral)제어기, PR(Proportional-Resonant), 제어기, DeadBeat (DB)제어기 등의 선형 제어기 이며, 각 제어기의 과도상태 응답특성과 정상상태 응답특성을 시뮬레이션으로 비교하였다. 또한 DSP의 특성에 의한 1 주기 지연, 리액턴스와 저항 변화 등에 강인한 DB제어기 관하여 논의 하겠다.

  • PDF

The Proportional Resonant Controller for Improving the Current Distortion of the Dual buck inverter in DCM Section Connected grid system with harmonic voltage (고조파 전압이 포함된 계통과 연계된 듀얼벅 인버터의 DCM 구간에서 전류 왜곡 개선을 위한 비례공진 제어기)

  • Choi, Minjae;Cho, Younghoon;Choi, Jinuk;Moon, Youngmin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.286-287
    • /
    • 2018
  • Recently, the development of renewable energy using solar energy is drawing attention. One of these PV systems, the Dual buck Inverter, is one of the topologies used in conjunction with the system, characterized by high efficiency and shoot-through reduction. However, current distortion appears severely in grid connection. So, in this paper, the method of compensation through PR controller was verified through simulation as an analysis of current distortion components and a control method to improve them.

  • PDF

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.

Design of Multiloop Control of Stand-alone Inverter for Power Quality Improvement under Unbalanced Load (불평형부하 시 전력품질 향상을 위한 독립형 인버터의 다중루프 제어기 설계)

  • Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.327-328
    • /
    • 2015
  • 본 논문은 불평형부하 조건에서 전력품질 향상을 위한 독립형 인버터의 다중루프 제어기를 설계하고 실험적으로 검증하였다. CVCF(Constant Voltage Constant Frequency) 제어를 수행하는 독립형 인버터에 정지좌표계 상에서 다중루프 특성을 갖는 전압-전류 제어기를 설계하여 불평형 부하에 안정적인 전력공급을 수행하도록 구현하였다. 전압 제어기는 기본파 및 선택적 고조파 제어특성을 갖는 PR(Proportional-Resonant, 비례-공진)제어기를, 전류제어기는 P제어기를 적용하였다. 50kW 독립형 인버터 프로토타입을 구현하였으며, 불평형부하 조건에서 기존 동기좌표계 PI 제어와 비교할 때, 선간전압 THD는 4.3%에서 0.9%, 불평형률은 4.3%에서 0.35%로 개선됨으로써 제안된 기법의 타당성을 검증하였다.

  • PDF

New Control Strategy for Conventional VSI in Islanded Microgrid to Enhance Voltage Quality under Nonlinear Loads

  • Dam, Duy-Hung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.351-352
    • /
    • 2015
  • This paper proposed a new control strategy for voltage source inverter (VSI) of effective fifth and seventh harmonic reduction in the point of common coupling (PCC) in islanded microgrid under nonlinear load without any additional hardware devices. The non-linear load regularly causes such harmonic distortion, which harmfully affect the performance of other loads or other distributed generation (DG) sources connect to the PCC. In order to improve the quality of delivered output voltage, these harmonic must be rejected. The proposed control strategy is developed based on the current controller formed by resonant controller parallel with a proportional integral controller, which perform on the fundamental reference frame. The reference current is estimated based on the voltage harmonic and the injecting power. The simulation and experimental results are shown to verify the effectiveness of proposed control method.

  • PDF

A New Control Strategy for Distributed Generation under Nonlinear loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.256-257
    • /
    • 2012
  • This paper presents a new control strategy to improve voltage performance of distributed generation (DG) under nonlinear loads. The proposed voltage controller consists of a proportional-integral and a repetitive controller where the repetitive controller behaves as a bank of resonant controllers to compensate harmonic voltage drop on system impedance due to nonlinear load current. As a result, the voltage at the point of common coupling (PCC) of the DG is regulated to be sinusoidal waveform regardless of the presence of nonlinear loads. In order to validate the effectiveness of the proposed voltage controller, simulations are carried out using PSIM software and results are compared with those with the conventional PI controller.

  • PDF

A Fuzzy Self-Tuning PID Controller with a Derivative Filter for Power Control in Induction Heating Systems

  • Chakrabarti, Arijit;Chakraborty, Avijit;Sadhu, Pradip Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1577-1586
    • /
    • 2017
  • The Proportional-Integral-Derivative (PID) controller is still the most widespread control strategy in the industry. PID controllers have gained popularity due to their simplicity, better control performance and excellent robustness to uncertainties. This paper presents the optimal tuning of a PID controller for domestic induction heating systems with a series resonant inverter for controlling the induction heating power. The objective is to design a stable and superior control system by tuning the PID controller with a derivative filter (PIDF) through Fuzzy logic. The paper also compares the performance of the Fuzzy PIDF controller with that of a Ziegler-Nichols PID controller and a fine-tuned PID controller with a derivative filter. The system modeling and controllers are simulated in MATLAB/SIMULINK. The results obtained show the effectiveness and superiority of the proposed Fuzzy PID controller with a derivative filter.