• 제목/요약/키워드: Proportional resonant

검색결과 109건 처리시간 0.044초

냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구 (DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator)

  • 김호진;김형진;김동윤;김장목
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

공진주 시험기를 이용한 국내 노상토의 동적 물성치 (Dynamic Properties of Korean Subgrade Soils Using Resonant Column Test)

  • 김동수;정충기;홍성영
    • 한국지반공학회지:지반
    • /
    • 제10권2호
    • /
    • pp.85-96
    • /
    • 1994
  • 공진주 실험기는 전단탄성계수, 영계수 및 감쇠비로 표현되는 지반의 동적물성치를 연구하기 위한 중요한 실내 실험법으로 널리 사용되어 왔다. 본 연구에서는 Stokoe식 공진주 실험기를 이용하여 전단 변형률 10-4%-10-1% 범위에서 대표적인 국내 노상토의 동적 물성치를 연구하였다. 전단탄성계수와 감쇠비는 한계변형률 Ix10-3%부근에서 부터 변형률의 영향을 받기 시작 하였다. 한계 변형률 이하에서 최대 전단탄성계수(Gmin)는 구속압 (Qc)에 따라 (Qc)0.61에 비례하여 증가하였고 최소감쇠 비(Dmin)는 1%-5.7% 범위에 분포하였다. 한계 변형률 이상에서 정규화 탄성계수 감소곡선은 Ramberg-Osgood식으로 잘 나타낼 수 있으며 Seed와 Idriss가 사질토 를 이용하여 얻은 감소곡선과 거의 일치하였다.

  • PDF

고성능 DCM-ZVS 스텝 업-다운 AC-DC 컨버터에 관한 연구 (A Study on Step Up-Down AC-DC Converter with DCM-ZVS of High Performance)

  • 곽동걸
    • 전기전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.335-342
    • /
    • 2012
  • 본 논문에서는 고효율과 고역률을 위한 새로운 DCM-ZVS 스텝 업-다운 AC-DC 컨버터에 대해 연구된다. 제안한 DCM-ZVS 컨버터에 사용된 스위칭 소자들은 새로운 유사공진 회로에 의해 소프트 스위칭 기법으로 동작되고, 펄스폭변조(PWM) 방식에 의한 전류불연속모드(DCM)로 구동된다. 제안한 컨버터의 유사공진 회로는 스텝 업-다운 인덕터와 무손실 스너버 커패시터로 구성되고, 또한 DCM에 의해 제어회로 기법과 제어회로 구성이 간단한 장점이 주어진다. 입력 교류 전류파형은 일정 스위칭 주파수에 의한 교류 입력전압의 크기에 비례한 유사 정현파형으로 된다. 그 결과, 제안한 DCM-ZVS 컨버터는 낮은 스위칭 손실과 고효율을 얻을 수 있으며, 컨버터의 입력역률은 거의 단위역률로 된다. 해석적 결과의 타당성은 다양한 컴퓨터 시뮬레이션과 실험 결과를 통해 입증된다.

Active Damping of LLCL Filters Using PR Control for Grid-Connected Three-Level T-Type Converters

  • Alemi, Payam;Jeong, Seon-Yeong;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.786-795
    • /
    • 2015
  • In this paper, an active damping control scheme for LLCL filters based on the PR (proportional-resonant) regulator is proposed for grid-connected three-level T-type PWM converter systems. The PR controller gives an infinite gain at the resonance frequency. As a result, the oscillation can be suppressed at that frequency. In order to improve the stability of the system in the case of grid impedance variations, online grid impedance estimation is applied. Simulation and experimental results have verified the effectiveness of the proposed scheme for three-phase T-type AC/DC PWM converters.

비례-공진 제어기를 이용한 반도체 변압기용 단상 계통 연계형 인버터 제어 (Proportional-Resonant Compensator Design of Single-Phase Grid-Connected Inverter for a SST)

  • 김보경;이준영;이원빈;정지훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.101-102
    • /
    • 2016
  • 반도체 변압기를 구성하는 단상 계통 연계형 인버터는 역률을 높이기 위해 전류를 계통 전압과 동상으로 제어하는 것이 요구된다. 산업에서 통상적으로 이용되는 비례-적분 제어기는 정현파의 참조 값을 추적할 때 항상 정상 상태 오차를 수반한다. 비례-공진 제어기는 기본 주파수에서 충분히 큰 이득을 도입함으로써 정상 상태 오차를 줄일 수 있다. 그러나 계단 응답에서 정상 상태 오차를 가진다는 단점이 있다. 본 논문에서는 단상 계통 연계형 인버터의 효과적인 전류 제어를 위하여 정현파 추적뿐만 아니라 계단 응답에서 정상 상태 오차 제거가 가능한 제어기를 제안한다. 본 논문에서 제안하는 제어기는 시뮬레이션을 통해 유효성을 검증하였다.

  • PDF

종동력을 받는 티모센코 보의 안정성에 미치는 크랙의 영향 (Effects of Crack on Stability Timoshenko Beam Subjected to Follower Force)

  • 안태수;손인수;윤한익
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.344-347
    • /
    • 2007
  • In this paper, the stability of a cracked cantilever beam subjected to follower force is presented. In addition, an analysis of the flutter instability(flutter critical follower force) of a cracked cantilever beam subjected to a follower compressive load is presented. Based on the Timoshenko beam theory. The vibration analysis on such cracked beam is conducted to identify the critical follower force for flutter instability based on the variation of the first two resonant frequencies of the beam. Besides, the effect of the crack's intensity and location on the flutter follower force is studied. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments. The crack is assumed to be in the first mode of fracture and to be always opened during the vibrations. Generally, the critical follower force for flutter is proportional to the crack depth.

  • PDF

PIR Speed Control Method of AC Motors Considering Time Delay in Speed Information

  • Lee, Jung-Ho;Choi, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2289-2297
    • /
    • 2017
  • Applying a periodic load torque to an AC motor generates a ripple, which is synchronized to the frequency of the periodic load torque, at the speed of the motor. Consequently, numerous studies have focused on reducing the speed ripple caused by the load torque. However, it is difficult to reduce the speed ripple when there is a time delay in acquiring speed information, such as that from a sensorless control. Therefore, we propose a speed control method for reducing speed ripples caused by a periodic load torque when there is a time delay in acquiring the speed information. The proposed method is verified by conducting simulations using the Simulink program from MATLAB, and by applying the method to an actual motor in which speed ripples occur due to a periodic load torque that is synchronized with the speed of the motor.

A New Soft Switching Step-Down/Up Converter with Inherent PFC Performance

  • Jabbari, Masoud;Farzanehfard, Hosein
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.835-844
    • /
    • 2009
  • In this paper a new buck-boost type DC-DC converter is presented. Its voltage gain is positive, all active elements operate under soft-switching condition independent of loading, magnetic isolation and self output short-circuit protection exist, and very fast dynamic operation is achievable by a simple bang-bang controller. This converter also exhibits appropriate PFC characteristics since its input current is inherently proportional to the source voltage. When the voltage source is off-line, it is sufficient to add an inductor after the rectifier, then near unity power factor is achievable. All essential guidelines to design the converter as a DC-DC and a PFC regulator are presented. Simulation and experimental results verify the developed theoretical analysis.

The Harmonic Current Mitigation of DFIG under Unbalanced Grid Voltage and Non-linear Load Conditions

  • Thinh, Quach Ngoc;Kim, Eel-Hwan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.83-84
    • /
    • 2011
  • This paper presents an analysis and a novel strategy for a doubly fed induction generator (DFIG) based wind energy conversion system under unbalanced grid voltage and non-linear load conditions. A proportional-resonant (PR) current controller is applied in both grid side converter (GSC) and rotor side converter (RSC). The RSC is controlled to mitigate the stator active power and the rotor current oscillations at double supply frequency under unbalanced grid voltage while the GSC is controlled to mitigate ripples in the dc-link voltage and compensate harmonic components of the network current. Simulation results using Psim simulation program are presented for a 2 MW DFIG to confirm the effectiveness of the proposed control strategy.

  • PDF

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.