• 제목/요약/키워드: Proportional resonance

검색결과 100건 처리시간 0.034초

Chemotherapy-Related Cardiac Dysfunction: Quantitative Cardiac Magnetic Resonance Image Parameters and Their Prognostic Implications

  • Jinhee Kim;Yoo Jin Hong;Kyunghwa Han;Jin Young Kim;Hye-Jeong Lee;Jin Hur;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제24권9호
    • /
    • pp.838-848
    • /
    • 2023
  • Objective: To quantitatively analyze the cardiac magnetic resonance imaging (CMR) characteristics of chemotherapy-related cardiac dysfunction (CTRCD) and explore their prognostic value for major adverse cardiovascular events (MACE). Materials and Methods: A total of 145 patients (male:female = 76:69, mean age = 63.0 years) with cancer and heart failure who underwent CMR between January 2015 and January 2021 were included. CMR was performed using a 3T scanner (Siemens). Biventricular functions, native T1 T2, extracellular volume fraction (ECV) values, and late gadolinium enhancement (LGE) of the left ventricle (LV) were compared between those with and without CTRCD. These were compared between patients with mild-to-moderate CTRCD and those with severe CTRCD. Cox proportional hazard regression analysis was used to evaluate the association between the CMR parameters and MACE occurrence during follow-up in the CTRCD patients. Results: Among 145 patients, 61 had CTRCD and 84 did not have CTRCD. Native T1, ECV, and T2 were significantly higher in the CTRCD group (1336.9 ms, 32.5%, and 44.7 ms, respectively) than those in the non-CTRCD group (1303.4 ms, 30.5%, and 42.0 ms, respectively; P = 0.013, 0.010, and < 0.001, respectively). They were not significantly different between patients with mild-to-moderate and severe CTRCD. Indexed LV mass was significantly smaller in the CTRCD group (65.0 g/m2 vs. 78.9 g/mm2; P < 0.001). According to the multivariable Cox regression analysis, T2 (hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 1.01-1.27; P = 0.028) and quantified LGE (HR: 1.07, 95% CI: 1.01-1.13; P = 0.021) were independently associated with MACE in the CTRCD patients. Conclusion: Quantitative parameters from CMR have the potential to evaluate myocardial changes in CTRCD. Increased T2 with reduced LV mass was demonstrated in CTRCD patients even before the development of severe cardiac dysfunction. T2 and quantified LGE may be independent prognostic factors for MACE in patients with CTRCD.

캐올리나이트 표면에서의 구리 수착 메카니즘 : 전자상자성공명 및 EXAFS 연구 (Copper(II) Sorption Mechanism on Kaolinite : An EPR and EXAFS Study)

  • Sung Pil Hyun;Kim F Hayes
    • 한국광물학회지
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2004
  • 캐올리나이트(KGa-lb) 표면에 수착된 구리를 전자상자성공명(electron paramagnetic resonance) 과 EXAFS (extended X-ray absorption fine structure) 분광법을 이용하여 연구하였다. 수착된 구리는 상온에서 $g_{iso}\;=\;2.19$의 등방성 전자상자성공명 흡수 신호를 보여 준다. 77 K에서 이러한 등방성 신호는 $g_{\$\mid$}\;=\;2.40,\;g_{\bot}\;=\;2.08$, 그리고 $A_{\$\mid$}\;=\;131\;G$의 전자상자성공명 파라미터를 가지는 축대칭 이방성 신호로 바뀐다. 전자상자성공명 분석 결과로부터 수착된 구리 이온이 찌그러진 $CuO_{6}$ 팔면체 구조의 외부권착물을 형성함을 알 수 있다. 수착 실험에서 용액의 pH가 증가함에 따라 수착된 구리의 양은 증가하였다. 그러나 등방성 신호는 수착된 구리의 양에 단순 비례하지는 않았다. 수착된 구리 이온이 높은 pH조건에서 표면 침전을 형성함을 가정함으로써 이러한 불일치를 해소할 수 있다. EXAFS 결과로부터 이러한 표면 침전의 존재를 확인할 수 있었다. 최적의 fitting 결과는 수착된 구리 이온이 $1.96\;{\AA}$ 거리에 결합된 4개의 수평 방향 산소와 $2.31\;{\AA}$ 거리에 결합된 2개의 축 방향 산소로 이뤄진 첫 번째 산소 껍질과 함께 $3.08\;{\AA}$ 거리에 평균 6.8개의 구리 이웃 원자들을 가짐을 보여준다. 이 연구는 캐올리나이트에 수착된 구리 이온의 국소 환경이 용액의 pH와 표면 농도에 따라 변화하며 그러한 변화를 연구하는데 전자상자성공명과 EXAFS가 효과적으로 활용될 수 있음을 보여 준다.

열발광, 전자스핀공명 및 DNA Comet 분석에 의한 대두의 방사선 조사 여부 검지 특성 (Detection Characteristics of TL, ESR and DNA Comet for Irradiated Soybeans)

  • 이은영;정재영;노정은;조덕조;권중호
    • 한국식품과학회지
    • /
    • 제34권1호
    • /
    • pp.18-23
    • /
    • 2002
  • 방사선 조사된 대두의 검지방법을 연구하기 위하여 국산 및 중국산 대두에 대하여 $0.5{\sim}4.0\;kGy$의 감마선을 조사하고 열발광(TL), 전자스핀공명(ESR) 및 DNA comet 특성을 비교 검토하였다. TL 측정에서 비조사구는 $280^{\circ}C$ 부근에서 매우 낮은 glow curve를 나타내었고, 감마선 조사구는 $200^{\circ}C$ 부근에서 조사선량에 의존적인 glow curve를 나타내었다. 재조사(re-irradiation) 방법에 의한 TL ratio$(TL_1/TL_2)$의 비교는 TL 측정 결과의 정확도를 높여 주었다. 원산지별 TL 특성 비교에서 국산을 중국산에 비해 높은 TL intensity를 나타내었다(p<0.01). 대두 껍질을 사용한 ESR 측정에서는 조사시료에서 cellulose radical 유래의 특이한 signal(g = 2.02374, 1.98715)을 보여주었고 중국산 시료의 ESR signal이 더 높게 나타났다. 비조사 대두의 DNA comet은 tail이 없거나 아주 짧은 tail을 가진 전형적인 intact cell을 나타내었다. 그러나 0.5 kGy 이상의 감마선 조사 시료에서는 조사선량에 의존적으로 comet의 tail length 증가와 더불어 comet의 크기 및 농도의 변화가 일어났다. 이상의 결과에서 TL, ESR 및 DNA comet의 분석은 대두의 방사선 조사 여부 확인을 가능하게 하였으며, 원산지별 검지특성의 차이는 거의 없었다.

비드와 나선형 공진기를 이용한 전원 노이즈 저감 방안 연구 (Power Noise Suppression Methods Using Bead with Spiral Resonator)

  • 정동호;강희도;육종관
    • 한국전자파학회논문지
    • /
    • 제24권2호
    • /
    • pp.152-160
    • /
    • 2013
  • 본 연구에서는 동시 스위칭에 의한 잡음 저감을 위하여 일반적으로 사용하는 비드와 더불어 나선형 공진기를 함께 사용하여 보다 향상된 광대역의 잡음 저감 특성을 확보하였다. 비드는 기본체배 주파수 아래 대역인 0.8 GHz 이내에서 효과적으로 잡음이 저감되고, 공진기는 공진기 턴 길이에 반비례한 공진 주파수 이내까지 잡음을 잘 저감할 수 있었다. 이것을 바탕으로 비드와 공진기를 함께 사용하면 각 주파수 영역에서 임피던스가 높은 성분에 의하여 영향을 받아 보다 광대역의 동시 스위칭에 의한 잡음 저감 특성을 얻을 수 있다. 22 nH 비드만을 사용한 경우 1, 2, 3, 그리고 4체배에서 각각 4.8, 2.0, 0, 0.6 dB의 노이즈 저감 특성을 얻었으나, 22 nH의 비드와 3턴 공진기를 함께 사용할 경우 9.5, 8.3, 6.1, 9.9 dB의 광대역에 걸친 잡음 감소 특성을 얻을 수 있었다. 비드가 없는 경우와 비교하여 22 nH 비드를 사용하면 전원단 흔들림이 76 mV에서 56 mV로 감소하고, 비드와 3턴 공진기를 함께 사용하면 34 mV로 감소함을 볼 수 있다. 즉, 비드와 공진기를 동시에 사용함으로써 보다 광대역의 동시 스위칭에 의한 잡음 저감 특성을 확보함을 보였다.

Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구 (Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm)

  • ;김태형;천송이;한용희;최기승;이광식;전재량;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.131-141
    • /
    • 2008
  • 목적: 물체 내부의 온도를 비침습적으로 측정할 수 있는 양성자 공명 주파수 이동에 의한 MR 온도영상의 재구성에 center array-sequencing 위상펼침(PU) 기법을 적용시켜 그 성능 및 유용성을 평가하고자 하였다. 대상 및 방법: MR 온도 영상에 앞서 잡음 수준이 다른 타원형 팬텀들을 컴퓨터 모의 실험으로 제작하고 제안된 PU방 법을 적용시켜 잡음에 대한 성능을 평가하였다. MR 실험은 PU 실험과 이를 이용한 온도분포영상획득 실험으로 구분하여 수행되었다. 1.5T MR 영상장치에서 무릎코일과 $T2^*$ 경사자장에코 펄스열을 이용하여 MR 영상을 얻었다. 물통, 오렌지, 아가젤 등의 팬텀을 실험 대상으로 하였고 자체 제작된 온수펌프 장치로 팬텀의 온도를 조절하였다. T 형 열전쌍 온도측정장치로 팬텀 온도를 측정하고 MR 온도영상 결과와 비교하였다. 획득된 MR영상의 위상분포는 제안된 PU방법으로 위상을 편 후 온도분포 영상을 재구성하였다. 가열 전 후의 온도변화와 MR 영상의 위상변화 관계를 이용하여 아가젤 팬텀 내의 MR온도분포 영상을 구하였다. 결과: 제안된 center array-sequencing PU 알고리즘을 이용하여 여러 팬텀에 대한 MR 위상영상의 접힘 현상을 기존 방법보다 간편하고 빠르게 제거할 수 있었고 이를 이용하여 MR 온도영상을 획득할 수 있었다. 결론: 본 연구는 제안된 center array-sequencing 위상펼침 방법이 잡음에 강하고 처리 속도가 빠를 뿐만 아니라 양성자 공명 주파수 이동의 성질을 이용한 MR 온도 영상 획득에 성공적으로 적용될 수 있음을 보였다.

  • PDF

Evaluation of Antioxidant Activities and Active Compounds Separated from Water Soluble Extracts of Korean Black Pine Barks

  • Shen, Chang-Zhe;Jun, Hong-Young;Choi, Sung-Ho;Kim, Young-Man;Jung, Eun-Joo;Oh, Gi-Su;Joo, Sung-Jin;Kim, Sung-Hyun;Kim, Il-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3567-3572
    • /
    • 2010
  • Black pine barks from the southern region of Korea were extracted using pressurized hot water and the water soluble extracts were then separated in a stepwise fashion using a variety of solvents, column chromatography (CC), thin layer chromatography (TLC), and high pressure liquid chromatography (HPLC). The antioxidant activities of each fraction and the active compounds were determined based on the radical scavenging activities of 2,2-diphenyl-1-picrylhydrazyl (DPPH), reductive potential of ferric ion, and total phenol contents. A DPPH test showed that the half maximal effective concentration ($EC_{50}$ value : $6.59{\pm}0.31\;{\mu}g/mL$) of the ethyl acetate fraction (ca. 0.67%) was almost the same as that of the control compounds and inversely proportional to the value of the total phenol contents. The cell viability of the water extracts was confirmed by methyl thiazol-2-yl-2,5-diphenyl tetrazolium bromide (MTT) with enzyme linked immune sorbent assay (ELISA). Catechin, epicatechin, quercetin and ferulic acid were isolated from the ethyl acetate fraction as active compounds and identified by nuclear magnetic resonance. The antioxidant activity as value of DPPH of each of the separated compounds was lower than the ethyl acetate fraction, and ferulic acid was the lowest among these compounds.

우리나라 MRI 이용의 사회경제적 특성 (A Study on the Socio-economic Characteristics of Magnetic Resonance Image(MRI) Uses in Korea)

  • 김루시아;문옥륜
    • 보건행정학회지
    • /
    • 제2권2호
    • /
    • pp.194-220
    • /
    • 1992
  • In recent years there has been a rapid influx of high cost MRI equipment into Korea. This diffusion has raised concerns about the changes it will bring for the health care utilization. Therefore, the purpose of this study is to identify socio-economic characteristics of MRI uses in Korea. A structured questionnaire was designed for this purpose, and 1, 091 users were surveyed at the 35 MRI units of 33 hospitals during a week, sometimes March 1992. The study reveals that high cost technology such as MRI, CT scanner is so prevalent in Korea. This is particularly the case in metropolitan areas. Among others, Seoul has the highest percentage of MRI equipment, 51.05%, Pusan 12.10% and Kwangju 11.9%. Unfortunately, most high cost technology equipments are foreign products. Thus, hospitals with such a high cost technology have difficulties in maintenance of the equipment. The average performance of MRI equipment has declined from 10.2 cases per day in 1988 to 7.16 cases in March 1992. Due to the rapid increase, the performance of MRI equipment seems to be deterioration. Male usere are dominant in the case of MRI use. The utilization rate has positively increased with the rise of educational level of users. The same is true for the level of income; the MRI utilization rate by income level shows that it is negatively proportional to income, which indicates that the poor have difficulties in the use of high cost technology. Particularly, the cost of MRI is so high that ordinary patients are unable to pay for it. For example, 86.3% of respondents have answered that the cost is too high even though they are insured by health insurance. This is the first empirical study on the use status of MRI. The information obtained in this study is sufficient to maintain that the Korean health insurance programme is urgently in need of improving the insurance benefit schemes. The easiest way to do this is to include provision of high cost technology service into the benefit package.

  • PDF

Measurement of the ICRH antenna phasing using antenna strap probe based diagnostic system in EAST tokamak

  • Liu, L.N.;Liang, Q.C.;Yang, H.;Zhang, X.J.;Yuan, S.;Mao, Y.Z.;Zhang, W.;Zhu, G.H.;Wang, L.;Qin, C.M.;Zhao, Y.P.;Cheng, Y.;Zhang, K.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3614-3619
    • /
    • 2022
  • To operate the ion cyclotron resonance heating (ICRH) antennas in a better heating state and produce relatively low impurities, it is necessary to control the antenna spectrum by changing the antenna phasing. As the electrical length of the antenna feeding transmission lines is changing as a matter of the standing wave pattern at the ceramic supports, 90° elbows, T-connectors and antenna loops, we chose to measure the current at the grounding points of the antenna loops by antenna strap probe. The voltage drops along a small, several millimeter-long paths at the end of the antenna loops give a signal that is proportional to the current in the antenna loop. Through the simulation of the antenna strap probe and the actual measurement of the antenna phasing under vacuum conditions, the reliability of the antenna strap probe based diagnostic system have been successfully proved. Moreover, this system was successfully applied to the ICRH daily experiments in the spring of 2021. In the near future, the active real-time feedback control of the antenna phasing system will be developed based on this diagnostic system in the EAST tokamak.

관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구 ([ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage)

  • 은충기;이영준;박오환;박영미;배재익;류지화;백대일;정수진;이선주
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.100-108
    • /
    • 2004
  • 목적 : Trypsin으로 관절연골의 변성을 인공적으로 유도한 뒤 관절연골의 구성성분인 glycosaminoglycan(GAG)의 소실을 생화학적으로 정량분석하고 $Gd(DTPA)^{2-}$-(gadolinium diethylene triamine pentaacetic acid)조영증강, 그리고 T1, T2, rho 이완시간등과 어떤 상관관계가 있는지를 조사함으로써 관절연골의 초기 퇴행성 변화에 대해서 자기공명영상(MRI)으로 관찰이 가능한 지를 알아보고자 하였다. 대상 및 방법 : 적출된 3개의 돼지 슬개골에서 실험에 사용될 관절연골조각을 폭 8 mm, 길이 10 mm 크기의 관절연골조각을 3개 만들었다. 분광광흡수계(spectrophotometry)에서 dimethylmethylene blue를 이용한 chondroitin sulfate standard의 흡수도를 측정하여 GAG을 정량분석 하였다. 관절연골을 배양할 용액은 0.2 mg/ml trypsin, 1 mM $Gd(DTPA)^{2-}$ 첨가된 trypsin, 그리고 대조군용 인산염완충식염수(phosphate buffered saline, PBS)의 3가지를 준비하였다. 배양시간은 1시간에서 5시간까지는 매시간마다 배양하였고 24시간과 48시간까지 배양하였다. MRI촬영은 1시간에서 5시간까지만 매시간마다 배양후 시행하였다. 1.5T 기기에서 MRI촬영은 T1강조영상(TR/TE, 450/22)과 혼합에코기법(mixed echo sequence) (TR/TE, 760/21-168, 8 echoes)등을 시행하였다. 모든 촬영에서 영상영역은 50 mm, 절편두께는 2 mm, 그리고 매트릭스는 $256\times512$ 였다. MRI촬영자료에서 관절연골부위를 픽셀단위로 비교분석 하였다. 배양이 끝난 관절연골은 hematoxylin & eosin, toluidine blue, alcian blue, trichrome 염색 등을 시행하여 관찰하였다. 결과 : Dimethylmethylene blue를 이용한 GAG의 정량분석결과 배양시간증가에 따라 GAG의 농도가 비례적으로 증가하였다. $Gd(DTPA)^{2-}$ 첨가된 trypsin배양에서 관절연골의 T1 강조 영상에서의 신호강도는 trypsin 배양에 비하여 평균 $42.0\%$ 증가하였고 4시간과 5시간배양에서는 trypsin에서만 배양한 관절연골에 비하여 신호강도가 더욱 뚜렷하게 증가되었다 (p<0.05). 관절연골의 T1, T2, rho 이완시간은 배양시간에 따라 유의성 있는 차이가 관찰되지 않았으나 $Gd(DTPA)^{2-}$ 첨가된 trypsin배양에서 T1이완시간의 증가가 관절연골의 표층부와 이행부에서 측정되었다. 조직검사결과 trypsin 배양의 관절연골에서 toluidine blue와 alcian blue염색에서 결손이 관찰되었다. 결론 : Trypsin 배양시간에 따라 관절연골의 GAG결손을 정량적으로 확인할 수 있었고 픽셀크기 $97.9\times195\;{\mu}m$인 MRI로 $Gd(DTPA)^{2-}$-조영증강 및 이완시간을 측정할 수 있었다. 배양시간에 따른 GAG결손은 T1, T2, rho 이완시간보다 $Gd(DTPA)^{2-}$-조영증강에서 유의한 차이를 관찰할 수 있었다. 그러므로 관절연골의 초기 퇴행성 변화를 진단하는 데는 T1강조영상에서 $Gd(DTPA)^{2-}$-조영증강정도를 비교하는 것이 가장 유용할 것으로 사료된다.

  • PDF

돼지 늑골에서 임플란트 수용부 깊이와 직경이 임플란트 일차 안정성에 미치는 효과 (THE EFFECT OF THE RECIPIENT SITE DEPTH AND DIAMETER ON THE IMPLANT PRIMARY STABILITY IN PIG'S RIBS)

  • 임진수;김현섭;국민석;박홍주;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.301-308
    • /
    • 2007
  • Purpose: This study was performed to compare and evaluate the effect of recipient site depths and diameters of the drills on the primary stability of implant in pig's ribs. Materials and methods: An intact pig's rib larger than 8 mm in width and 20 mm in height; RBM(resorbable blasting media) surface blasted ${\phi}3.75mm$ and 8.0 mm long USII Osstem Implants (Osstem Co., Korea) were used. To measure the primary stability, $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used. They were divided into 6 groups according to its recipient site formation method: D3H3, D3H5, D3H7, D3.3H3, D3.3H5, D3.3H7. Each group had, as indicated, 10 implants placed, and total 60 implants were used. The mean value was obtained by 4-time measurements each on mesial, distal, buccal, and lingual side perpendicular to the long axis of the implant using $Periotest^{(R)}$ and $Osstell^{TM}$. For statistical analysis one-way ANOVA was used to compare the mean value of each group, and the correlation between placement depths and the primary stability, and that of measuring instruments was analyzed using SPSS 12.0. Results: The primary stability of the implants increased as the placement depths increased (p<0.05), and showed a proportional relationship (p<0.01). The primary stability increased when the diameter of the recipient site was smaller than that of the implant but with no statistical significance. There was a strong correlation between $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.01). Conclusion: These results suggest that increasing the placement depth of implants enhances the primary stability of implant.