THE EFFECT OF THE RECIPIENT SITE DEPTH AND DIAMETER ON THE IMPLANT PRIMARY STABILITY IN PIG'S RIBS

돼지 늑골에서 임플란트 수용부 깊이와 직경이 임플란트 일차 안정성에 미치는 효과

  • Lim, Jin-Su (Department of Oral and Maxillofacial Surgery, School of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Kim, Hyun-Syeob (Department of Oral and Maxillofacial Surgery, School of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Kook, Min-Suk (Department of Oral and Maxillofacial Surgery, School of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Park, Hong-Ju (Department of Oral and Maxillofacial Surgery, School of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Oh, Hee-Kyun (2nd stage of Brain Korea 21, Chonnam National University)
  • 임진수 (전남대학교 치의학전문대학원 구강악안면외과학교실, 치의학연구소) ;
  • 김현섭 (전남대학교 치의학전문대학원 구강악안면외과학교실, 치의학연구소) ;
  • 국민석 (전남대학교 치의학전문대학원 구강악안면외과학교실, 치의학연구소) ;
  • 박홍주 (전남대학교 치의학전문대학원 구강악안면외과학교실, 치의학연구소) ;
  • 오희균 (전남대학교, 2단계 BK 21)
  • Published : 2007.07.31

Abstract

Purpose: This study was performed to compare and evaluate the effect of recipient site depths and diameters of the drills on the primary stability of implant in pig's ribs. Materials and methods: An intact pig's rib larger than 8 mm in width and 20 mm in height; RBM(resorbable blasting media) surface blasted ${\phi}3.75mm$ and 8.0 mm long USII Osstem Implants (Osstem Co., Korea) were used. To measure the primary stability, $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used. They were divided into 6 groups according to its recipient site formation method: D3H3, D3H5, D3H7, D3.3H3, D3.3H5, D3.3H7. Each group had, as indicated, 10 implants placed, and total 60 implants were used. The mean value was obtained by 4-time measurements each on mesial, distal, buccal, and lingual side perpendicular to the long axis of the implant using $Periotest^{(R)}$ and $Osstell^{TM}$. For statistical analysis one-way ANOVA was used to compare the mean value of each group, and the correlation between placement depths and the primary stability, and that of measuring instruments was analyzed using SPSS 12.0. Results: The primary stability of the implants increased as the placement depths increased (p<0.05), and showed a proportional relationship (p<0.01). The primary stability increased when the diameter of the recipient site was smaller than that of the implant but with no statistical significance. There was a strong correlation between $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.01). Conclusion: These results suggest that increasing the placement depth of implants enhances the primary stability of implant.

Keywords

References

  1. Adel R, Lekholm V, Rocker B et al : A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 10 : 387, 1981
  2. Esposito M, Hirsch JM, Lekholm U et al : Biological factors contributing to failures of osseointegrated oral implants : Success criteria and epidemiology. Euro J Oral Science 106 : 527, 1998 https://doi.org/10.1046/j.0909-8836..t01-2-.x
  3. Glauser R, Sennerby L, Meredith N et al : Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Clin Oral Implants Res 15 : 428, 2004 https://doi.org/10.1111/j.1600-0501.2004.01036.x
  4. Lindeboom JAH, Tjiook Y, Kroon FHM : Immediate placement of implants in periapical infected sites : A prospective randomized study in 50 patients. Oral Surg Oral Med Oral Pathol Oral Radiol Endocrinol 101 : 705, 2006 https://doi.org/10.1016/j.tripleo.2005.08.022
  5. Degidi M, Piattelli A : Comparative analysis study of 702 dental implants subjected to immediate functional loading and immediate nonfunctional loading to traditional healing periods with a follow-up of up to 24 months. Int J Oral Maxillofac Implants 20 : 99, 2005
  6. Simsek B, Simsek S : Evaluation of success rates of immediate and delayed implants after tooth extraction. Chinese Med J 116 : 1216, 2003
  7. Korean Academy of Oral and Maxillofacial Implantology : Testbook of Oral & Maxillofacial Implantology: Vol II Advanced concepts and techniques, 1st Edition. Seoul, Daehan Publishing Co., 2006, p326
  8. Meredith N : Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 : 491, 1998
  9. Brunski JB : The influence of force, motion and related qunatities on the response of bone to implants : Noncemented total hip arthroplasty, New York, Raven, 1998, p.7
  10. McNutt MD, Chou CH : Current trends in immediate osseous dental implant case selection criteria. J Dent Edu 67 : 850, 2003
  11. Douglass GL, Merin RL : The immediate dental implant. J California Dent Assoc 30 : 362, 2002
  12. Fugazzotto PA : Simplified technique for immediate implant insertion into extraction sockets : report of technique and preliminary results. Implant Dent 11 : 79, 2002 https://doi.org/10.1097/00008505-200201000-00018
  13. Kaneko TM : Pulsed oscillation technique for assessing the mechanical state of the dental implant-bone interface.Biomat 12 : 555, 1991 https://doi.org/10.1016/0142-9612(91)90050-K
  14. Meredith N, Alleyne D, Cawley P : Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 7 : 261, 1996 https://doi.org/10.1034/j.1600-0501.1996.070308.x
  15. Meredith N : A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng 26 : 275, 1998 https://doi.org/10.1615/CritRevBiomedEng.v26.i4.20
  16. Derhami K, Wolfaardt JF, Faulkner G et al : Assessment of Periotest device in baseling mobility measurements of craniofacial implants. Int J Oral Maxillofac Implants 10 : 221, 1995
  17. Kim SJ, Han DH : Periotest assessment of dental implant mobility: A clinical study. J Korean Acad Prosthodont 26 : 758-771, 1998
  18. Kim YK, Hwang JW, Yun PY et al : Multicentric prospective clinical study of Korean implant system: Early stability measured by Periotest. J Kor Dent Assoc 42 : 873-881, 2004
  19. Manz MC, Morris HF, Ochi S : An evaluation of the Periotest system. Part I: Examination reliability and repeatability of readings. Implant Dent 1 : 142, 1992 https://doi.org/10.1097/00008505-199205000-00006
  20. Sennerby L, Meredith N : Resonance frequency analysis : Measuring implant stability and osseointegration. Compend 19 : 493, 1998
  21. Meredith N, Shagaldi F, Alleyne D et al : The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 8 : 234, 1997 https://doi.org/10.1034/j.1600-0501.1997.080310.x
  22. Becker W, Sennerby L, Bedrossian E et al : Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial. J Perio 76 : 391, 2005 https://doi.org/10.1902/jop.2005.76.3.391
  23. Huang HM, Chiu CL, Yeh CY et al : Early detection of implant healing process using resonance frequency analysis. Clin Oral Implants Res 14 : 437, 2003 https://doi.org/10.1034/j.1600-0501.2003.00818.x
  24. Lachmann S, Jager B, Axmann D et al : Resonance frequency analysis and damping capacity assessment. Part 1 : an in vitro study on measurement reliablity and a method of comparision in the determination of primary dental implant stability. Clin Oral Implants Res 17 : 75, 2006 https://doi.org/10.1111/j.1600-0501.2005.01173.x
  25. Lachmann S, Laval JY, Jager B et al : Resonance frequency analysis and damping capacity assessment. Part 2 : peri-implant bone loss follow-up. An in vitro study with the Periotest and $Osstell^{TM}$instruments. Clin Oral Implants Res 17 : 80, 2006 https://doi.org/10.1111/j.1600-0501.2005.01174.x
  26. Buser D, Nydegger T, Oxland T et al : Interface shear strength of titanium with sandblasted and acid-etched surface : A biomechanical study in the maxilla of miniature pigs. J Biomed Mater Res 45 : 75, 1999 https://doi.org/10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO;2-P
  27. Lee JT, Heo SJ, Han CH et al : Histomorphometic and resonance frequency analysis of bone healing around titanium implant with two different surface treatment. J Korean Acad Oral Maxillofac Implants 9 : 64-71, 2005
  28. Misch CE : Contemporary implant dentistry, 2nd ed. Chicago, Mosby, 2000, p.136