• 제목/요약/키워드: Proportional Integral Derivative

검색결과 222건 처리시간 0.027초

축-베어링 계의 불균형 응답에 대한 능동 제어 베어링의 효과 (Effect of Active Control Bearing on Unbalance Response of a Rotor-Bearing System)

  • 노병후;김경웅
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.316-321
    • /
    • 2001
  • The paper presents the unbalance response of a rotor-bearing system supported by an active control bearing. The proportional, derivative and integral controls are employed for the control algorithm of an active control bearing to suppress the unbalance response of a rotor-bearing system. Results of analytical investigations on the unbalance responses of a rotor supported by an active control bearing are presented for various control gains. It is found that the unbalance response of a rotor can be greatly suppressed by the proportional, derivative or integral control of the bearing. The proportional control is more effective than the derivative control at low rotational speed, and the derivative control is more effective than the proportional control at high rotational speed. In the case of the integral control of the bearing , the unbalance response of a rotor is increased as a general rule. However, the integral control of the bearing is extremely superior to proportional or derivative control at very low rotational speed.

  • PDF

축-베어링 계의 불균형 응답에 대한 능동 제어 베어링의 효과 (Effect of Active Control Bearing on Unbalance Response of a Rotor-Bearing System)

  • 노병후;김경웅
    • Tribology and Lubricants
    • /
    • 제18권2호
    • /
    • pp.99-104
    • /
    • 2002
  • The paper presents the unbalance response of a rotor-bearing system supported by an active control bearing. The proportional, derivative and integral controls are investigated fur the control algorithm of an active control bearing to suppress the unbalance response of a rotor-bearing system. Results of analytical investigations on the unbalance responses of a rotor supported by an active control bearing are presented for various control gains. It is found that the unbalance response of a rotor can be greatly suppressed by the proportional, derivative or integral control of the bearing. The proportional control is more effective than the derivative control at low rotational speed, and the derivative control is more effective than the proportional control at high rotational speed. In the case of the integral control of the bearing, the unbalance response ova rotor is increased as a general rule. However, the integral control of the bearing is extremely superior to proportional or derivative control at very low rotational speed.

스텝응답에 기반한 PID/PIDA 제어기의 자동동조 (Auto-tuning of PID/PIDA Controllers based on Step-response)

  • 안경필;이준성;임재식;이영일
    • 제어로봇시스템학회논문지
    • /
    • 제15권10호
    • /
    • pp.974-981
    • /
    • 2009
  • In this paper, a method of auto-tuning of PID (Proportional-Integral-Derivative) and PIDA (Proportional-Integral-Derivative-Acceleration) controllers is proposed that can be applied to a time-delayed second order model. The proposed identification method is based on step responses, but it can be easily automated rising digital controller unlike the existing graphical identification methods. We provide a ways to yield parameter identifications which is independent to initial values of the plants. The tuning rule is based on the pole-placement strategy and is formulated so that it can be implemented using a digital controller with ease.

MRPID 제어기의 튜닝 방법연구 (A Study on the MRPID parameter tuning method)

  • 류현준
    • 전자공학회논문지SC
    • /
    • 제44권6호
    • /
    • pp.21-28
    • /
    • 2007
  • Mutiresolution proportional-integral-derivative(MRPID) 제어기는 웨이브렛 기반의 다해상도 응답을 이용해서 에러 신호에 포함되어 있는 잡음과 외란을 제거하는 필터 역할을 해준다. 다해상도 응답의 특징상 샘플링 주파수가 높을 경우 상대적으로 고주파성분이 남아있음으로 인해 응답속도가 떨어지는 대신에 오버슈트가 제거되고, 낮을 경우 신호 성분이 제거되므로 인해 응답속도가 향상되지만 오버슈트가 증가 되는 결과를 보였다. 본 논문에서는 proportional-integral-derivative(PID) 제어기와 MRPID 제어기의 응답을 이용한 샘플링 주파수를 설정하는 기법과, MRPID 제어기의 특성을 고려한 파라미터 설정기법을 제안한다. 모의실험을 통해서 제안된 기법의 타당성을 검증하였다.

Control of the pressurized water nuclear reactors power using optimized proportional-integral-derivative controller with particle swarm optimization algorithm

  • Mousakazemi, Seyed Mohammad Hossein;Ayoobian, Navid;Ansarifar, Gholam Reza
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.877-885
    • /
    • 2018
  • Various controllers such as proportional-integral-derivative (PID) controllers have been designed and optimized for load-following issues in nuclear reactors. To achieve high performance, gain tuning is of great importance in PID controllers. In this work, gains of a PID controller are optimized for power-level control of a typical pressurized water reactor using particle swarm optimization (PSO) algorithm. The point kinetic is used as a reactor power model. In PSO, the objective (cost) function defined by decision variables including overshoot, settling time, and stabilization time (stability condition) must be minimized (optimized). Stability condition is guaranteed by Lyapunov synthesis. The simulation results demonstrated good stability and high performance of the closed-loop PSO-PID controller to response power demand.

능동 제어 베어링으로 지지된 축-베어링 시스템의 동특성에 관한 연구 (A Study on Dynamic Characteristics of a Rotor-Bearing System Supported by Actively Controlled Hydrodynamic Journal Bearing)

  • 노병후;김경웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.635-638
    • /
    • 2001
  • This paper presents the dynamic characteristics of r rotor-bearing system supported by an actively controlled hydrodynamic journal bearing. The proportional, derivative and integral controls are adopted for the control algorithm to control the hydrodynamic journal bearing with an axially groove. Also, the cavitation algorithm implementing the Jakobsson-Floberg-olsson boundery condition is adopted to predict cavitation regions in the fluid film more accurately than conventional analysis, which uses the Reynolds condition. The speed at onset of instability of a rotor-bearing system is increased by both proportional and derivative control of the bearing. The integral control has no effect on stability characteristics of hydrodynamic journal bearing. The PD-control is more effective than proportional or derivative control. Results show the active control of bearing can be adopted for the stability improvement of a rotor-bearing system.

  • PDF

능동 제어 유체 윤활 베어링으로 지지된 축-베어링 시스템의 동특성에 관한 연구 (A Study on Dynamic Characteristics of a Rotor-Bearing System Supported by Actively Controlled Fluid Film Journal Bearing)

  • 노병후;김경웅
    • 한국정밀공학회지
    • /
    • 제18권8호
    • /
    • pp.116-121
    • /
    • 2001
  • The paper presents the dynamic characteristics of a rotor-bearing system supported by an actively controlled hydrodynamic journal bearing. The proportional. derivative and integral controls are adopted for the control algorithm to control the hydrodynamic journal bearing with an axial groove. Also, the cavitation algorithm implementing the Jakobsson-Floberg-Olsson boundary condition is adopted to predict cavitation regions in the fluid film more accurately than conventional analysis, which uses the Reynolds condition. The speed at onset of instability of a rotor-bearing system is increased by both proportional and derivative control of the bearing. The proportional control increases the stability threshold without affecting the whirl ratio. However, for the derivative control of the bearing, increase of stability threshold speed is accompanied by a parallel reduction of the whirl ratio. The integral control has no effect on stability characteristics of hydrodynamic journal bearing. The PD-control is more effective than proportional or derivative control. Results 7how the active control of bearing can be adopted for the stability improvement of a rotor-bearing system.

  • PDF

Control of a pressurized light-water nuclear reactor two-point kinetics model with the performance index-oriented PSO

  • Mousakazemi, Seyed Mohammad Hossein
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2556-2563
    • /
    • 2021
  • Metaheuristic algorithms can work well in solving or optimizing problems, especially those that require approximation or do not have a good analytical solution. Particle swarm optimization (PSO) is one of these algorithms. The response quality of these algorithms depends on the objective function and its regulated parameters. The nonlinear nature of the pressurized light-water nuclear reactor (PWR) dynamics is a significant target for PSO. The two-point kinetics model of this type of reactor is used because of fission products properties. The proportional-integral-derivative (PID) controller is intended to control the power level of the PWR at a short-time transient. The absolute error (IAE), integral of square error (ISE), integral of time-absolute error (ITAE), and integral of time-square error (ITSE) objective functions have been used as performance indexes to tune the PID gains with PSO. The optimization results with each of them are evaluated with the number of function evaluations (NFE). All performance indexes achieve good results with differences in the rate of over/under-shoot or convergence rate of the cost function, in the desired time domain.

Robustness of optimized FPID controller against uncertainty and disturbance by fractional nonlinear model for research nuclear reactor

  • Zare, Nafiseh;Jahanfarnia, Gholamreza;Khorshidi, Abdollah;Soltani, Jamshid
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.2017-2024
    • /
    • 2020
  • In this study, a fractional order proportional integral derivative (FOPID) controller is designed to create the reference power trajectory and to conquer the uncertainties and external disturbances. A fractional nonlinear model was utilized to describe the nuclear reactor dynamic behaviour considering thermal-hydraulic effects. The controller parameters were tuned using optimization method in Matlab/Simulink. The FOPID controller was simulated using Matlab/Simulink and the controller performance was evaluated for Hard variation of the reference power and compared with that of integer order a proportional integral derivative (IOPID) controller by two models of fractional neutron point kinetic (FNPK) and classical neutron point kinetic (CNPK). Also, the FOPID controller robustness was appraised against the external disturbance and uncertainties. Simulation results showed that the FOPID controller has the faster response of the control attempt signal and the smaller tracking error with respect to the IOPID in tracking the reference power trajectory. In addition, the results demonstrated the ability of FOPID controller in disturbance rejection and exhibited the good robustness of controller against uncertainty.

Effect of feedback on PID controlled active structures under earthquake excitations

  • Nigdeli, Sinan Melih
    • Earthquakes and Structures
    • /
    • 제6권2호
    • /
    • pp.217-235
    • /
    • 2014
  • In this paper, different feedback control strategies are presented for active seismic control using proportional-integral-derivative (PID) type controllers. The parameters of PID controller are found by using an numerical algorithm considering time delay, maximum allowed control force and time domain analyses of shear buildings under different earthquake excitations. The numerical algorithm scans combinations of different controller parameters such as proportional gain ($K_p$), integral time ($T_i$) and derivative time ($T_d$) in order to minimize a defined response of the structure. The controllers for displacement, velocity and acceleration feedback control strategies are tuned for structures with active control at the first story and all stories. The performance and robustness of different feedback controls on time and frequency responses of structures are evaluated. All feedback controls are generally robust for the changing properties of the structure, but acceleration feedback control is the best one for efficiency and stability of control system.