• 제목/요약/키워드: Proportional Integral

검색결과 582건 처리시간 0.031초

A modified model reference adaptive system for the speed identification of induction motors

  • Hur, Namho;Hong, Kichul;Nam, Kwanghee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.427-431
    • /
    • 1996
  • The MRAS proposed by Schauder [8] is modified to improve robustness to the change of load torque and/or the variation of the stator resistance. The difference between the voltage and the current model is fed into the current model via proportional and integral gains. In order to generalize the MRAS, supposing that the rotor speed is time varying, we add a compensating term to the current model. It does not alter the Popov's integral inequality condition. Also, the asymptotic stability of the modified MRAS (MMRAS) is shown with the stability proof technique as in the original paper. By the simulation works, it is verified that the MMRAS obtains improved performance than the original MRAS.

  • PDF

전동기 구동을 위한 반포화 적분-비례 제어기 설계 (Anti-windup IP Controller for Motor Drives)

  • 박종규;손병성;유치밍;이순영;신휘범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.80-83
    • /
    • 1999
  • The windup phenomenon appears and results in performance degradation such as large overshoot, slow settling time when the integral-proportional (IP) controller output is saturated. An anti-windup IP controller is proposed to improve the control performance for the motor drives. The proposed algorithm is applied to the current control of a vector-controlled induction motor driven by a pulse width modulated(PWM) voltage-source inverter. The integral state is separately controlled corresponding to whether the IP controller output is saturated or not. The experimental results show that the current response has much improved performance such as little overshoot and fast settling time.

  • PDF

전기유압식 모터용 위치제어 시스템의 설계 (Design of a Position Control System for Electro-hydraulic Motors)

  • 박진길;진강규;노영오;한봉주;정주윤;박재식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권3호
    • /
    • pp.30-41
    • /
    • 1992
  • For the state feedback controller which measures only partial state variables, a state observer can be used to give the estimates of unmeasurable states. In this paper, the delayed state feedback method instead of the state observer for desingning a tracking controller of electro-hydraulic control system is presented. The controller design is based on augmenting the original system by one additional integral and proportional element which compensates for the effect of the integral control and on feeding back the measurable state variables and their delayed values. The performance of the proposed position control system is compared with both that of the full state feedback control system and that of the digital PID control system tuned by the Ziegler-Nichols method and by the parameter readjustment through the computer simulation. And then robustness against unmeasurable constant disturbace and parameter variations during operations is also checked.

  • PDF

다중 시간지연 공정을 위한 개선된 다중루프 PI 제어기 설계 (Design of Advanced Multi-loop PI Controller for Multi-delay Processes)

  • 트롱부;이문용
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.77-82
    • /
    • 2010
  • An analytical method for robust design of the multi-loop proportional-integral (PI) controller is proposed for various types of multi-delay processes. On the basis of the direct synthesis and generalized IMC-PID approach, the analytical tuning rules of the multi-loop PI controller are firstly derived for achieving the desired closed-loop response, and the structured singular value synthesis is then utilized for the tradeoffs between the robust stability and performance by adjusting only one design parameter (i.e., the closed-loop time constant). To verify the superiority of the proposed method, the simulation studies have been conducted on a wide variety of multivariable processes. The multi-loop PI controller designed by the proposed method shows a fast, well-balanced and robust response with the minimum integral absolute error (IAE) in compared with other renowned methods.

안티와인드업 기법을 가지는 PID 제어기의 EA 기반 동조 (EA-based Tuning of a PID Controller with an Anti-windup Scheme)

  • 진강규;박동진
    • 제어로봇시스템학회논문지
    • /
    • 제19권10호
    • /
    • pp.867-872
    • /
    • 2013
  • Many practical processes in industry have nonlinearities of some forms. One commonly encountered form is actuator saturation which can cause a detrimental effect known as integrator windup. Therefore, a strategy of attenuating the effects of integrator windup is required to guarantee the stability and performance of the overall control system. In this paper, optimal tuning of a PID (Proportional-Integral-Derivative) controller with an anti-windup scheme is presented to enhance the tracking performance of the PID control system in the presence of the actuator saturation. First, we investigate effective anti-windup schemes. Then, the parameters of both the PID controller and the anti-windup scheme are optimally tuned by an EA (Evolutionary Algorithm) such as the IAE (Integral of Absolute Error) is minimized. A set of simulation works on two high-order processes demonstrates the benefit of the proposed method.

화력발전소의 과열기증기의 온도제어 (Temperature Control of Superheater Steam in Thermal Power Plant)

  • 신휘범;이순영
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2006-2011
    • /
    • 2010
  • The superheater in the thermal power plant makes the wet steam into the dry steam with high temperature and high pressure by using the boiler heat. The dry steam pressure rotates the turbine-generator system. The efficiency and life time of the boiler heavily depends on the steam temperature regulation. The steam temperature can be deviated from the reference by the MW demand of the power plant. It is therefore required that the PI(proportional-integral) controller should be robust against the disturbance such as the MW demand. In this paper, the PI controller with the integral state predictor is proposed and applied to regulate the steam temperature of the superheater, and it is compared with the conventional PI controller operated in the thermal power plant in view of control performance.

Performance Improvement of Active Queue Management for Internet Routers

  • Lim, Hyuk;Park, Kyung-Joon;Park, Eun-Chan;Park, Chong-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.77.1-77
    • /
    • 2001
  • In this paper, we propose a control scheme for improving the performance of a conventional Proportional-Integral (PI) controller for Active Queue Management (AQM) supporting TCP flows. When the PI controller is used for AQM, the windup phenomenon of the integral action causes the performance degradation. Therefore we model AQM as a system with a saturator and apply anti-windup methods to the PI controller for AQM. We compare the performances of anti-windup algorithm with the conventional PI controller through ns simulations. The simulation results show that the PI controller with anti-windup method performs better than the conventional PI controller.

  • PDF

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

FDC 동조제어기법을 이용한 유압-기계식 수문 제어 모니터링 (Sluice Gates Control Monitoring of Oil Pressure-Machine Using FDC Tuning Control Technique)

  • 허광희;김충길
    • 대한토목학회논문집
    • /
    • 제30권4A호
    • /
    • pp.337-342
    • /
    • 2010
  • 일반적으로 하천 시설에 사용되는 수문은 기계식 및 유압식, 혼합식 권양기에 의하여 개폐되며, 구조물의 크기 및 구조상 2개 이상의 인양장치로 동조를 이루며 안전하게 개폐되어야 한다. 수문의 개폐 시 설계상 정확히 고려할 수 없는 수압 및 마찰로 인하여 구조물에 추가적인 하중이 발생하게 된다. 이러한 추가적인 하중은 수문의 끼임 현상 및 권양기의 과부하 등을 초래하고, 이는 수문의 안전에 중대한 영향을 미치게 된다. 본 논문에서는 이러한 수문의 개폐 시 발생하는 불안전한 요소에 대응하여 권양기가 동조를 이룰 수 있도록 유압 및 변위를 동시에 고려한 FDC(Force-Displacement Control)시스템을 설계하였다. 설계된 FDC 시스템을 XG5000프로그램의 PID 기능을 이용하여 구현하였으며, 다중 유압 실린더 수문 권양기(winch) 모형을 제작하여 FDC 시스템을 실험적으로 검증하였다. 실험 결과 개발한 FDC 시스템은 수문의 개폐 시 발생하는 다양한 외부하중에 대응하여, 다중 유압 실린더로 이루어진 수문 권양기가 동조를 이루며 개폐됨을 확인하였다. 실험 결과로부터 FDC 시스템은 수문 권양기에 적용시 효과적임을 확인 하였다.

전동기 위치 제어를 위한 PI-PD 제어기 설계 (A PI-PD Controller Design for the Position Control of a Motor)

  • 장주형;김상훈
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.60-66
    • /
    • 2017
  • This paper presents the design of a proportional-integral (PI)-proportional-derivative (PD) position controller without using a speed controller in motor drive systems. Unlike the existing PI-PD position controller design methods, the proposed controller is designed by reducing the entire position control system to a second-order transfer function. Thus, the gain values for the PI-PD position controller can be determined easily by a given bandwidth of the position controller. The PI-PD position controller designed by the proposed method is adopted for position control in an interior permanent magnet synchronous motor drive system to confirm the validity of the proposed design method. The effectiveness of the proposed design method is confirmed through experiments.