• Title/Summary/Keyword: Proper Supply Method

Search Result 132, Processing Time 0.033 seconds

An Experimental Study on the Proper Supply Method of Metal Cutting Coolant (절삭유 공급 방식의 최적화를 위한 실험적 연구)

  • 강재훈;송준엽;최종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.977-980
    • /
    • 2004
  • Metalworking fluids (MWFs) are fluids used during machining and grinding to prolong the life of the tool, carry away debris, and protect the surfaces of work pieces. These fluids reduce friction between the cutting tool and the work surface, reduce wear and galling, protect surface characteristics, reduce surface adhesion or welding and carry away generated heat. Workers can be exposed to MWFs by inhaling aerosols (mists) and by skin contact with the fluid. Skin contact occurs by dipping the hands into the fluid, splashes, or handling workpieces coated with the fluids. The amount of mist generated (and the resulting level of exposure) depends on many factors. To reduce the environmental pollution wastes and the potential health risks associated with occupational exposures to MWFs, it is required to establish optimum MWFs supply method and condition with minimum quantity in all over the mechanical machining field including high-speed type heavy cutting process.

  • PDF

A Study on the Establishment of Proper Metalworking Fluids Supply Method to Reduce the amount Used (절삭유 사용량의 억제를 위한 적절한 공급 방식의 설정을 위한 연구)

  • 강재훈;송준엽;송철원;최종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1803-1806
    • /
    • 2003
  • Metalworking fluids (MWFs) are fluids used during machining and grinding to prolong the lift of the tool, carry away debris, and protect the surfaces of work pieces. These fluids reduce friction between the cutting tool and the work surface. reduce wear and galling, protect surface characteristics, reduce surface adhesion or welding and carry away generated heat. Workers can be exposed to MWFs by inhaling aerosols (mists) and by skin contact with the fluid. Skin contact occurs by dipping the hands into the fluid, splashes, or handling workpieces coated with the fluids. The amount of mist generated (and the resulting level of exposure) depends on many factors. To reduce the environmental pollution wastes and the potential health risks associated with occupational exposures to MWFs, it is required to establish optimum MWFs supply method and condition with minimum quantity in all over the mechanical machining field including high-speed type heavy cutting process.

  • PDF

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

Development of Auxiliary Power Supply for Industrial Magnetron (산업용 마그네트론 보조전원 개발)

  • Ryoo, H.J.;Kim, J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.47-49
    • /
    • 2007
  • For the magnetron, two kinds of auxiliary power is required to generate proper heat and electromagnetic field. In this paper the development of filament power supply and magnet power supply for high power industrial magnetron is studied. The filament power supply which is generate proper heat, even it doesn't require high power like main power supplies, has many consideration such as high voltage insulation and power control coordinated with high voltage cathod current to maintain constant heat generation. The novel control method using constant resistance control is proposed for accurate control of filament power supply.

  • PDF

A Study on the Determination of Water Storage-Supply Capacity of Agricultural Reservoir (소규모 농업용 저수지의 저류량-용수공급능력 결정에 관한 연구)

  • 안승섭;정순돌;이증석;윤경덕;장인수
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1217-1226
    • /
    • 2002
  • This study aims at the effective estimation of water supply capacity of small scale reservoir and the proposal of the data which is necessary to establish the water resources management plan of down stream area of the reservoir in the future by comparison and examination about reservoir operation technique for the security of agricultural water in small scale reservoir. The result of flow calculation by Tank model is used for the input data as the inflow data which is needed for the analysis of water supply capacity. Stochastic method, simulation method, and optimization method are used to examine the water supply capacity, and water security amount is compared with each method. From the analyses of water supply capacities by each method, slightly different results are shown in spite of the effort to compare them equally using input data such as inflow data under equal conditions, and the comparison of water supply capacities by each method are as follows; linear planning method, simulation method, and transition probability matrix method in the order of amount from the largest. It is thought that the simulation method in which comparatively reasonable application of the inflow data is possible and is simulated in successive time series dam operation of the three methods used in this study thus, simulation model is proper to estimate the water supply capacity of agricultural small scale reservoir. And it is judged that the heightening of efficiency of water resources utilization according to the development of downstream area of dam may be possible using the upward readjusted water supply amount of $55.18{\tiems}10^6ton$ and $63.7{\times}10^6ton$ at 95% and 90% supply reliability respectively which are above the planning water supply amount of $50.0{\times}10^6$ton when the simulation method is introduced as the standard.

Enteral Nutrition in Pediatric Patients

  • Yi, Dae Yong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • Pediatric patients require specialized attention and have diverse demands for proper growth and development, and thus need a different approach and interest in nutritional assessment and supply. Enteral nutrition is the most basic and important method of nutritional intervention, and its indications should be identified. Also, the sites, modes, types, and timing of nutritional intervention according to the patient's condition should be determined. In addition, various complications associated with enteral nutrition supply should be identified, and prevention and treatment are required. This approach to enteral nutrition and proper administration can help in the proper growth and recovery of pediatric patients with nutritional imbalances or nutritional needs.

Determination of the Optimal Location for Water Treatment Plants in the Decentralized Water Supply System (분산형 용수공급시스템 구축을 위한 정수처리시설 최적 위치 결정)

  • Chang, Dong-Eil;Ha, Keum-Ryul;Jun, Hwan-Don;Kim, Jeong-Hyun;Kang, Ki-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Major issues in water supply service have changed from expansion of service area to improvement of service quality, i.e., water quality and safety, and early response to emergency situation. This change in the service concept triggers the perceptions of limitation with the current centralized water supply system and of necessities of decentralized (distributed) water supply system (DWSS), which can make up the limitations. DWSS can reduce the possibility of water supply outage by establishing multiple barriers such as emergency water supply system, and secure better water quality by locating treatment facilities neighboring consumers. On the other hand, fluctuation of water demand will be increased due to the reduced supply area, which makes difficult to promptly respond the fluctuating demand. In order to supplement this, hybrid water supply system was proposed, which combined DWSS with conventional water supply system using distributing reservoir to secure the stability of water supply. The Optimal connection point of DWSS to existing water supply network in urban area was determined by simulating a supply network using EPANET. Optimal location of decentralized water treatment plant (or connection point) is a nodal point where changes in pressure at other nodal points can be minimized. At the same time, the optimal point should be selected to minimize hydraulic retention time in supply network (water age) to secure proper water quality. In order to locate the point where these two criteria are satisfied optimally, Distance measure method, one of multi-criteria decision making was employed to integrate the two results having different dimensions. This methodology can be used as an efficient decision-support criterion for the location of treatment plant in decentralized water supply system.

A Study on the Improvement of Ventilation Effectiveness in High-rise Apartment Buildings (초고층 공동주택의 환기효율 개선에 관한 연구)

  • Park, Jin-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.87-94
    • /
    • 2006
  • The efficiency of ventilation system is one of the most important issues of designing ventilation in high-rise apartment buildings. The purpose of this study is to analyze the ventilation efficiency of ventilation system by experimental study using CO2 gas method. The results of this paper can be summarized as follows; (1) An appropriate ventilation including opening planning, mechanical and hybrid system are required. (2) The supply diffuser of ventilation system should be located near the contaminant source. (3) The return grill should be located along with supply diffuser for proper ventilation. and the return grill should be located near or right above the contaminant source. (4) However, the supply location right above the contaminant source has to be avoided. and the supply diffuser should be installed in module with return grill increase ventilation effectiveness.

Development of the method for optimal water supply pump operation considering disinfection performance (소독능을 고려한 송수펌프 최적운영기법 개발)

  • Hyung, Jinseok;Kim, Kibum;Seo, Jeewon;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

The Systematic Evaluation of the SCADA System Proposals for Multi-purpose Dam and Water Supply Office (댐 및 수도 사무소 감시제어시스템의 체계적 기술평가 방안)

  • Paik, D.H.;Lee, E.W.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.217-219
    • /
    • 1998
  • Korea Water Resources Corporation (KOWACO) annually supplies about 2 billion Kwh and 7.3 billion $m^3$ with its 10 multi purpose dams and 20 water supply offices. For the proper control and management of the above utilities, sequential control equipment and SCADA/DCS have been operated and maintained. In this paper, 8 control system evaluations for hydropower dam, water supply, electric power and subway projects during 1984-1997 were reviewed and analyzed. The systematic evaluation method has been established in the points of the purpose, method, procedure, evaluation team, evaluation criteria, total evaluation table and the contents of final recommendation report. With keeping in mind the essential points, it is expected for the more effective and fair evaluation of bids.

  • PDF