• Title/Summary/Keyword: Proof load

Search Result 83, Processing Time 0.028 seconds

Reliability analysis of piles based on proof vertical static load test

  • Dong, Xiaole;Tan, Xiaohui;Lin, Xin;Zhang, Xuejuan;Hou, Xiaoliang;Wu, Daoxiang
    • Geomechanics and Engineering
    • /
    • v.29 no.5
    • /
    • pp.487-496
    • /
    • 2022
  • Most of the pile's vertical static load tests in construction sites are the proof load tests, which is difficult to accurately estimate the ultimate bearing capacity and analyze the reliability of piles. Therefore, a reliability analysis method based on the proof load-settlement (Q-s) data is proposed in this study. In this proposed method, a simple ultimate limit state function based on the hyperbolic model is established, where the random variables of reliability analysis include the model factor of the ultimate bearing capacity and the fitting parameters of the hyperbolic model. The model factor M = RuR / RuP is calculated based on the available destructive Q-s data, where the real value of the ultimate bearing capacity (RuR) is obtained by the complete destructive Q-s data; the predicted value of the ultimate bearing capacity (RuP) is obtained by the proof Q-s data, a part of the available destructive Q-s data, that before the predetermined load determined by the pile test report. The results demonstrate that the proposed method can easy and effectively perform the reliability analysis based on the proof Q-s data.

Analytical and Field Investigation of Bridge Stress Distribution under Proof Load (기지하중을 받는 교량구조물의 현장 계측 및 해석에 따른 응력분포 연구)

  • Eom, Jun-Sik;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.139-146
    • /
    • 2003
  • The objective of the presented study is to develop an efficient procedure of proof load testing for existing bridges. By analytical methods, some of these bridges are not adequate to carry normal highway traffic. However, the actual load carrying capacity is often much higher than what can be determined by conventional analysis. Proof load testing can reveal the hidden strength reserve and thus verify the adequacy of the tested bridge. Proof load level required for meaningful tests should be sufficiently higher than legal load. In the state of Michigan, the legal 11-axle truck can weigh up to 685 kN. In this study, a combination of two military tanks and two Michigan 11-axle trucks was used. The proof loads were gradually increased to ensure the safety of the test. After each move, measurements were taken. For the considered bridge, stress levels were rather low compared to pre-test analysis results. This is due to incorrect material strength, structural contribution of nonstructural components such as parapets and railings, and partially fixed supports.

Evaluation of the Performance Test Load through the Estimation of Vertical Loads on Vibration-Proof Fastening Systems (방진체결장치에 작용하는 수직하중 평가를 통한 성능시험하중 평가)

  • Yang, Sin Chu
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.777-784
    • /
    • 2016
  • In this study, regulation of the performance test load of a vibration-proof fastening system used in urban railways was established through evaluation of the loads that it bears in the field. In order to investigate the range of the dynamic stiffness of the vibration-proof fastening system, dynamic stiffness tests were carried out for three types of vibration-proof fastening system that can be domestically supplied. Train and track interaction analyses in the frequency domain were carried out to evaluate the dynamic wheel loads. The track irregularity, which is a very important input factor in train and track interaction analysis, was considered as a PSD (Power Spectral Density) function, which was derived based on the measured data. The loads on the vibration-proof rail fastening system were evaluated considering various operating conditions in the urban railway. Regulation of the performance test load of the vibration-proof rail fastening system was established based on the evaluated loads.

Local Resistance Factor Update of Driven Steel Pipe Piles Using Proof Pile Load Test Results (검증용 정재하시험을 이용한 타입강관말뚝의 저항계수 보정)

  • Park, Jae Hyun;Kim, Dongwook;Chung, Choong Ki;Kim, Sung Ryul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6C
    • /
    • pp.259-266
    • /
    • 2011
  • Conducting statistical analysis of foundation resistance using sufficient number of well-performed load test results is prerequisite for the calibration of reliable resistance factors for foundation LRFD. In this study, a rational analysis method is proposed so that the proof pile load test results can be reflected in update of resistance statistical characteristics based on Bayesian theory. Then, resistance factors for driven steel pipe piles compatible with Korea foundation practices are updated by implementing this rational analysis method. To accomplish the resistance factor updates, (1) prior pile resistance distribution is constructed based on the results of pile load tests, which loads are imposed at least up to their ultimate limit loads. (2) likelihood function is obtained from the results of proof pile load tests, and (3) posterior pile resistance distribution is updated by combining these prior pile resistance distribution and likelihood function. The resistance factors are updated using the posterior pile resistance following the first-order reliability method (FORM). From the possible results of five consecutive proof pile load tests, the updated resistance factors vary within ranges of 0.27-0.96 and 0.19-0.68 for target reliability indices of 2.33 and 3.0, respectively. Consequently, it was found that the Bayesian theory-implemented method enables the updates of resistance factors in an efficient way when reliable resistance factors are not available due to the lack of well-performed pile load test results.

Structural Design and Proof Test of a 2MW Wind Trubine Blade (2MW 로터 블레이드 구조설계 및 인증시험)

  • Bang, Jo-Hyug;Kim, Yang-Soo;Ryu, Ji-Yune;Kim, Doo-Hoon;Park, Sun-Ho;Park, Byoung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • A GFRP based composite blade was developed for a 2MW wind energy conversion system of type class IIA. The blade sectional geometry was designed to have a general shell-spar and shear web structure. The load cases specified in the IEC61400-1 international specification were considered. For withstanding all relevant extreme loads, the structural analysis for the complete blade was performed using a commercial FEM code. The static load carrying capacity, blade tip deflection and natural frequencies were evaluated to satisfy the strength and stability requirements in accordance with the IEC61400-1 and GL Regulations. The prototype blade was passed the structural proof test for GL certification.

  • PDF

Proof Load Test and Integrity Assessment of Segmental PC Box-girder Bridges (Segmental PC 박스거더교의 검증재하시험 및 건전성평가)

  • 조효남;임종권;옥승범;지광습
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.132-141
    • /
    • 1995
  • This study is intended to propose practical but systematic and rational approaches for proof load test and integrity assessment of segmental PC box-girder bridges. The proposed models cover the whole range of field tests and assessment of such as inspections, nondestructive tests, static and dynamic load tests, structural analysis, and integrity assessment for the evaluation of load carrying capacity, serviceability, and durability of PC box-girder bridges. They are applied to a newly constructed precast segmental PC box-girder bridge which is a part of the Seoul interior circuit elevated expressway.

  • PDF

A Study on the Effects of the Train Gust induced by High speed train at 350km/h on the Simple Vertical Surfaces Parallel to the Track (고속열차 350km/h 주행시 열차풍이 방음벽 등 궤도에 수직평행한 선로변 구축물에 미치는 영향에 관한 연구)

  • Kim, Jae-Bok;Nam, Sung-Won;Ko, Tae-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.529-544
    • /
    • 2007
  • After rapid running is begun in domestic, problem by the train gust that was not considered at existent train running appeared. If the High-Speed railway business speed rises by 350km/h in the future, is going to become more big problem. This study conducts an experiment that measure in local about KTX train beside Gyeong-Bu High speed railroad track about aerodynamics effect that happen by passage of train and analyzed. In case KTX II runs with the 350km/h speed, forecasted effect that get in the simple vertical surfaces parallel to tracks according to distance from rail center. Compared construction size with structural analysis in case do not consider with case that consider the train gust about sound proof walls representatively. As a result, proposed wind load standard that apply at sound proof walls design.

  • PDF

Weight Drop Impact Tests of Earthquake-Proof Table (내진테이블의 중량물 낙하 충격실험)

  • Eom, Tae Sung;Huh, Seok Jae;Park, Tae Won;Lee, Sang Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.369-378
    • /
    • 2018
  • Full-scale seismic retrofit of old and deteriorated masonry buildings requires a lot of cost and time. In such buildings, installing an emergency evacuation space can be considered as an alternative. In this study, requirements of the earthquake-proof table used as an emergency evacuation space for buildings hit by earthquake are investigated. Load conditions required for the table, including the impact effects due to building debris drop, are explained. To investigate the impact effects in more detail, weight drop test is performed for an prototype earthquake-proof table. In the test, the weight of the falling object and free fall height were considered as the main test parameters. The results showed that the duration of impact is very short (0.0226~0.0779sec), and thus the impact forces increase to 15.8~45.2 times the weight of the falling object. Based on these results, design considerations and performance verification criteria of the earthquake-proof table as an emergency evacuation space are given.

Dynamic performance of girder bridges with explosion-proof and aseismic system

  • Wang, Jingyu;Yuan, Wancheng;Wu, Xun;Wei, Kai
    • Structural Engineering and Mechanics
    • /
    • v.61 no.3
    • /
    • pp.419-426
    • /
    • 2017
  • Recently, the transportation of dangerous explosive goods is increasing, which makes vehicle blasting accidents a potential threat for the safety of bridge structures. In addition, blasting accidents happen more easily when earthquake occurs. Excessive dynamic response of bridges under extreme loads may cause local member damage, serviceability issues, or even failure of the whole structure. In this paper, a new explosion-proof and aseismic system is proposed including cable support damping bearing and steel-fiber reinforced concrete based on the existing researches. Then, considering one 40m-span simply supported concrete T-bridge as the prototype, through scale model test and numerical simulation, the dynamic response of the bridge under three conditions including only earthquake, only blast load and the combination of the two extreme loads is obtained and the applicability of this explosion-proof and aseismic system is explored. Results of the study show that this explosion-proof and aseismic system has good adaptability to seism and blast load at different level. The reducing vibration isolation efficiency of cable support damping bearing is pretty high. Increasing cables does not affect the good shock-absorption performance of the original bearing. The new system is good at shock absorption and displacement limitation. It works well in reducing the vertical dynamic response of beam body, and could limit the relative displacement between main girder and capping beam in different orientation so as to solve the problem of beam falling. The study also shows that the enhancement of steel fibers in concrete could significantly improve the blast resistance of main beam. Results of this paper can be used in the process of antiknock design, and provide strong theoretical basis for comprehensive protection and support of girder bridges.

Structural Analysis and Proof Test of Composite Rotor Blades for Wind Turbine (풍력발전기용 복합재 블레이드의 구조 해석 및 인증시험)

  • Park, Sun-Ho;Han, Kyung-Seop
    • New & Renewable Energy
    • /
    • v.4 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • GFRP based composite rotor blades were developed for 750 kW & 2 MW wind turbines. The blade sectional geometry was designed to have a general shell-spar and shear web structure. For verifying the structural safety under all relevant extreme loads specified in the GL guidelines, the structural analysis of the rotor blades was performed using commercial FEM codes. The static load carrying capacity, blade tip deflections and natural frequencies were evaluated to satisfy the strength and stability requirements. Full-scale proof tests of rotor blades were carried out with optical fiber sensors for real-time condition monitoring. Finally, the prototype of each rotor blade passed all proof tests for GL certification.

  • PDF