• Title/Summary/Keyword: Proof Test

검색결과 279건 처리시간 0.027초

내분진형 오일 쿨러 개발에 관한 연구 (Study of Development of a Dust-proof Oil Cooler)

  • 이영림;전의식
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.60-65
    • /
    • 2008
  • A typical louvered-fin oil cooler can be easily contaminated under dusty environment hence resulting in poor performance of a heat exchanger. Thus, in this study, a dust-proof oil cooler has been studied with a unique shape of a 3-dimensional wavy fin since non-louvered fins could have better performance under dusty environment compared to louvered fins. Recently, they have been introduced to commercial and constructional vehicles in Japan. At first numerical analysis has been done to optimize the angle of the wavy fin so that the oil cooler developed can satisfy the target performance. The wavy fin has been then made with roll-forming and roll-pitch stands, and a prototype of an oil cooler with the wavy fin has been finally built with brazing. The performance test showed that the heat release rate of the oil cooler was well beyond the target, 4.94kW and the air-side pressure drop was below the criterion, 0.19kPa. In addition, the results showed that the numerical prediction was effective enough to design the dust-proof oil cooler that satisfies the performance criteria.

마이크로파 가열건조법에 의한 압축 구조용 목재의 방염 및 내구성 (Flame Resistance and Durability of Compressed Structural Wood through Microwave Heat Drying Method)

  • 임남기
    • 한국건축시공학회지
    • /
    • 제11권2호
    • /
    • pp.162-170
    • /
    • 2011
  • 침엽수 구조재인 S.P.F 수종을 마이크로파로 단시간에 급속 건조시켜 액상의 인산염계 방염약제에 시간별로 침지시킨 후 2차 마이크로파 가열을 한 다음 3.8cm의 두께에서 1cm를 압축시켜 방염 후 처리물품 시험과 내구성 시험을 실시한 결과 1차 마이크로파 적정 가열시간은 5kW에서 7분 동안 가열할 경우 목표 함수율(4~5%)을 만족하는 것으로 나타났다. 인산염계 방염약제에 침지, 건조 후 3kW로 9분 동안 가열시켜 연화된 상태에서 압축된 목재의 함수율 측정결과 시험편 모두 외부용 목재의 적정 함수율인 12~14%의 범위를 만족하는 것으로 나타났다 또한 압축된 목재의 방염후 처리물품 시험을 통한 방염성능은 방염약제에 30분간 침지된 시험편이 가장 우수한 것으로 나타났으며 압축된 목재의 성능 시험 결과 경도, 못뽑기 저항, 압축, 휨강도, 전단 강도 모두 약 2~3배 이상 역학적 특성이 향상되었다.

Dynamic performance of girder bridges with explosion-proof and aseismic system

  • Wang, Jingyu;Yuan, Wancheng;Wu, Xun;Wei, Kai
    • Structural Engineering and Mechanics
    • /
    • 제61권3호
    • /
    • pp.419-426
    • /
    • 2017
  • Recently, the transportation of dangerous explosive goods is increasing, which makes vehicle blasting accidents a potential threat for the safety of bridge structures. In addition, blasting accidents happen more easily when earthquake occurs. Excessive dynamic response of bridges under extreme loads may cause local member damage, serviceability issues, or even failure of the whole structure. In this paper, a new explosion-proof and aseismic system is proposed including cable support damping bearing and steel-fiber reinforced concrete based on the existing researches. Then, considering one 40m-span simply supported concrete T-bridge as the prototype, through scale model test and numerical simulation, the dynamic response of the bridge under three conditions including only earthquake, only blast load and the combination of the two extreme loads is obtained and the applicability of this explosion-proof and aseismic system is explored. Results of the study show that this explosion-proof and aseismic system has good adaptability to seism and blast load at different level. The reducing vibration isolation efficiency of cable support damping bearing is pretty high. Increasing cables does not affect the good shock-absorption performance of the original bearing. The new system is good at shock absorption and displacement limitation. It works well in reducing the vertical dynamic response of beam body, and could limit the relative displacement between main girder and capping beam in different orientation so as to solve the problem of beam falling. The study also shows that the enhancement of steel fibers in concrete could significantly improve the blast resistance of main beam. Results of this paper can be used in the process of antiknock design, and provide strong theoretical basis for comprehensive protection and support of girder bridges.

FRP로 보강된 철근콘크리트보의 열전도해석 및 내화성능 평가 (Heat Conduction Analysis and Fire Resistance Capacity Evaluation of Reinforced Concrete Beams Strengthened by FRP)

  • 임종욱;박종태;김정우;서수연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.1-8
    • /
    • 2018
  • 본 연구의 목적은 해석적 방법을 통하여 내화 재료의 특성을 파악하고 섬유 강화 폴리머로 보강된 철근콘크리트의 보의 적절한 내화설계 방법을 제안하는 것이다. 이를 위해, 내화재료의 가열실험을 실시하고 유한요소해석을 통해 열전도율과 비열을 구하고 또한 고온에서 FRP로 보강된 철근콘크리트 보 실험체에 대한 유한요소 해석을 통해 실험결과와 해석결과를 비교하였다. 이 과정에서 실험과 해석적 접근의 신뢰성을 확인하였다. 최종적으로 FRP로 보강된 철근콘크리트 보의 열적특성을 제안된 해석 방법으로 분석하고 고온으로 감소된 휨내력을 계산하였다. 최종적으로 제안된 방법을 이용하여 FRP로 보강된 부재에서 고온 노출시 열특성을 반영한 부재의 열전도를 파악하고 이를 이용하여 내력을 산정할 수 있는 것으로 나타났다.

The Effect of Office Layouts and Ambient Office Sounds on the Simple Tasks of White Collar Workers

  • Yoon, Heakyung Cecilia
    • Architectural research
    • /
    • 제8권2호
    • /
    • pp.11-16
    • /
    • 2006
  • The purpose of this study is to scrutinize the effect of office layouts and ambient office sounds on the performance of office workers involved with a proof-reading test (simple task). Twenty subjects, who were professional researchers and computer programmers, were from three different office layouts: 1) Nine subjects from a combined office type with open meeting places and closed individual offices; 2) five from an open office with rectangular individual workstations, and 3) six from an open office with triangular individual workstations. Architects and consultants working in the field of office have reported from interviews and their own observations that occupants' satisfaction differs as their office layouts vary although the sizes are the same. This finding leads to the hypothesis of this experiment. Proof-reading test results were obtained from three different office layouts (combined office type, rectangular and triangular individual workstations in open offices) under two different sound conditions (quiet background sound and ambient sound of their own workplace) for 10 minutes. The test analysis shows the mean test score of subjects from the triangular individual workstations in open offices is significantly different from the mean test scores of subjects from the combined office type and the rectangular individual workstations in open offices.

ON THE SIZES OF DUAL GROUPS

  • Song, Joungmin
    • 대한수학회보
    • /
    • 제59권3호
    • /
    • pp.609-615
    • /
    • 2022
  • We give a formula for the sizes of the dual groups. It is obtained by generalizing a size estimation of certain algebraic structure that lies in the heart of the proof of the celebrated primality test by Agrawal, Kayal and Saxena. In turn, by using our formula, we are able to give a streamlined survey of the AKS test.

비탈형영구 거푸집용 모르터의 내구성 및 역학적 특성에 관한 실험적 연구 (A Experimental Study on The Durability and Mechanical of Permanent Form Mortar)

  • 김우재;표순주;임남기;김형남;김성식;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.731-736
    • /
    • 1998
  • The dynamics and Durability of Permanent Form Mortar were observed. The results were as the followings. To construct New permanent form, this study constructed permanent form with fiber mortar. In this course glass fiber and polymer, fine aggregate were substituted with river sand and crush sand. To understand material quality effect, flexible mortar and inflexible mortar were tested. According to the microstructure of polymermatrix test by SEM, higher density by Co-matrix effect from polymer addiction was observed. This is considered to increase acid-resistanc, impact proof strenght. In the test of durability of freezing and thawing, polymer mortar was proved to be water proof. It seems to be improved in its characteristics in proportion to increasing W/C ratio. When the W/C ratio is 30%, it is most effective.

  • PDF

지하구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure)

  • 권시원;권기주;이종용;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.652-655
    • /
    • 2004
  • In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if tills costs a lot. It was not arrange the standard for performance evaluation test method and quality maintenance for materials, even it has been used various injection repairing agent. In conclusion, We suggest that the test method for repair materials for leakage to establish the leakage repairing technology as increase of structure demand, so that the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is increasing a lot to regulate the water-proof technology and the leakage repair technology.

  • PDF

Segmental PC 박스거더교의 검증재하시험 및 건전성평가 (Proof Load Test and Integrity Assessment of Segmental PC Box-girder Bridges)

  • 조효남;임종권;옥승범;지광습
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.132-141
    • /
    • 1995
  • This study is intended to propose practical but systematic and rational approaches for proof load test and integrity assessment of segmental PC box-girder bridges. The proposed models cover the whole range of field tests and assessment of such as inspections, nondestructive tests, static and dynamic load tests, structural analysis, and integrity assessment for the evaluation of load carrying capacity, serviceability, and durability of PC box-girder bridges. They are applied to a newly constructed precast segmental PC box-girder bridge which is a part of the Seoul interior circuit elevated expressway.

  • PDF

Proof tests of REBCO coated conductor tapes for device applications through electromechanical property assessment at 77 K

  • Mark Angelo Diaz;Michael De Leon;Hyung-Seop Shin;Ho-Sang Jung;Jaehun Lee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.34-37
    • /
    • 2023
  • The practical application of REBCO coated conductor (CC) tapes, vital for energy transmission (e.g., cable application) and high-field magnets (e.g., coil application), necessitates efficient and simple quality assessment procedures. This study introduces a systematic approach to assess the electromechanical properties of REBCO CC tapes under 77 K and self-field conditions. The approach involves customized tensile and bending tests that clarify the critical current (Ic) response of the CC tapes under mechanical loads induced by tension and bending. This study measures the retained Ic values of commercially available GdBCO CC tapes under 250 MPa tensile stress and 40 mm bending diameter. Through experimentation, the study demonstrates the resilience of these tapes and their suitability for applications. By presenting a simplified stress-based analysis and a bending test of the tapes, the study contributes to effective quality assessment methods for the development of practical superconducting products.