• 제목/요약/키워드: Projection Moire Topography

검색결과 18건 처리시간 0.024초

Digital moire 형상측정 시스템의 보정에 관한 연구 (A Study on the Calibration of Shape Measurement System Using Digital moire)

  • 김도훈;유원재;박낙규;강영준
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

Digital moire 형상측정 시스템의 보정에 관한 연구 (A Study on the Calibration of Shape Measurement System Using Digital moire)

  • 유원재;김도훈;안재웅;강영준;노형민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구 (A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face)

  • 유원재;최정표;안중근;강영준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

인체흉상 합성을 위한 3차원 형상 측정에 관한 연구 (A study on 3-D shape measurement for the composition of human bust)

  • 안중근;강영준;최정표;유원재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.220-223
    • /
    • 1997
  • Moire topography method is a well-known non-contacting 3-D measuement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topography is very attractive because of it's high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the 2x-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the 2x-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구 (A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method.)

  • 유원재;김도훈;강영준;백성훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF

위상천이 영사식 모아레법을 이용한 고속 3차원 형상복원 (East 3-Dimensional Shape Reconstruction Using Phase-Shifting Grating Projection Moire Method)

  • 최이배;구본기;정연구
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 추계학술발표 논문집
    • /
    • pp.111-115
    • /
    • 1998
  • A phase-shifting projection moire method particularly intended for high-speed three-dimensional shape reconstruction of diffuse objects is presented. Emphasis is on realization of phase-shifting fringe analysis in projection moire topography using a set of line grating pairs designed to provide different phase shifts in sequence. Further a time-integral fringe capturing scheme is devised to remove undesirable high frequency original grating patterns in real-time without time-consuming software image processing. Finally the performances of the proposed method are discussed with measurement results.

  • PDF

영사식 무아레 토포그래피에서 격자 주기에 따른 물체거리와 광원의 위치에 대한 무늬 민감도 변화 (Fringe Sensitivity of Projection Moire Topography Due to Position of Light Source and Object Distance According to Grating Periods)

  • 오현석;주윤제;조재흥
    • 한국광학회지
    • /
    • 제27권2호
    • /
    • pp.67-72
    • /
    • 2016
  • 영사식 무아레 토포그래피에서 실제 물체에 대한 측정오차를 줄이기 위해서는 물체높이에 따른 무늬차수의 변화율인 무늬 민감도에 대한 조사가 필수적이며, 또한 무늬 민감도를 활용을 하면 절대 차수 결정이 매우 편리하고 정확해진다. 영사기를 사용한 영사식 무아레 토포그래피에서 무늬차수를 결정하기 위한 변수는 광원의 위치와 물체의 위치, 격자주기이다. 이 변수들 중에서 광원의 위치를 횡축으로 움직이는 광원 횡축 이동법과 물체를 종축으로 움직인 물체 종축 이동법에 따른 무늬 민감도를 격자주기에 따라 서로 비교하고 이를 분석하였다. 그 결과 광원 횡축 이동법에서 광원과 상검출기 사이의 간격이 클수록 민감도가 높았으나, 물체 종축 이동법에서 물체와 결상렌즈 사이의 거리가 작을수록 민감도가 높았다. 그리고 두 방법에서 격자주기가 작을수록 민감도가 더 높았으며 변수 변화에 따른 무늬 민감도 변화량은 더 컸다.

디지털 영사식 무아레를 이용한 3차원 형상 측정과 응용에 관한 연구( I ) (A Study on 3-D Shape Measurement and Application by using Digital Projection $Moir\acute{e}$ ( I ))

  • 유원재;노형민;이동환;강영준
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.88-93
    • /
    • 2005
  • $Moir\acute{e}$ topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by $Moir\acute{e}$ topography has been required, since the method was frequently applied to the engineering and medical fields. The 3-D measurement using projection $Moir\acute{e}$ topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection $Moir\acute{e}$ topography was tested to measuring object with $2\pi-ambiguity$ problems. The experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi-ambiguity$ problems can be effectively overcome so as to treat large step discontinuities in measured objects.

모아레 측정법과 설문지 조사를 통한 경기도 S고등학교 재학생의 신체자각증상과 배부체형에 대한 실태조사 (A Study on the Back shape and self-conscious symptoms of the students in S High school Using the Moire measurement and Questionnaire investigation)

  • 장규태;김장현;백현
    • 대한한방소아과학회지
    • /
    • 제17권2호
    • /
    • pp.55-74
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the back shape and self-conscious symptoms of the students in S High school using the phase-shifting scanning grating projection Moire interferometer and Questionnaire investigations. Methods : In this study the subjects consisted of 317 pupils[168 boys(53%), 149girls(47%)] attending S high school in Sungnamsi, Kyoungkido in 2002. Their ages ranged from sixteen to eighteen. With the phase-shifting scanning grating projection moire interferometer, the posterior views of the body were taken to see if there are correlation of remainder value of the height spot of left & right shoulder blade and gluteal region in Moire topography. And using questionnaire investigation, we investigated the self-conscious symptoms. Results : 1. In questionnaire investigation, we observed that the ratios of self-conscious symptoms of girls are more than that of boys. The ratios of headache, neck pain, lower back pain, digestive symptom were more than 70% in boys and girls. 2. In Moire topography, more frequent findings of scapular region were observed that left scapular area were higher than right(in boys 69.3%, 60%, 100%, aged 16,17,18, in girls 66.8%, 40.5%, 58.8% aged 16,17,18). 3. More frequent findings of gluteal region were observed that left scapular area were higher than right(in boys 75.2%, 60%, 36.4% aged 16,17,18, in girls 61.1%, 46.8%, 64.7% aged 16,17,18) 4. More frequent findings of reminder value of the vertical lines of cervical and buttock region in Moire topography were observed that the vertical lines of cervical region were inclined to left than the vertical lines of buttock(in boys 73.3%, 92.2%, 100% aged 16,17,18, in girls 72.2%, 77.2%, 73.5% aged 16,17,18) Conclusion : From these results, we found that the self-conscious symptoms were more than in girls than boys; the ratio of headache, neck pain, Lower back pain, digestive symptom was more than the others; the back shape of high school students were not balanced in scapular and buttock region; necks were inclined to left than buttock.

  • PDF

프레스 성형 공정 개선을 위한 역설계 시스템의 적용 (Application of Reverse Engineering System for Improvement of Press Forming Process)

  • 김수용;김민주;이승수;전언찬;김순경
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.412-419
    • /
    • 2003
  • The most product is manufactured by mould in usual life. From drawing to manufacturing is to be automatically. But inspection is handwork usually. An alternative idea of this problem is reverse engineering. In this study, press forming is measured by 3D non-contact coordinate measuring machine and problem will be analyzed by comparing with 3D data Through the study, it will achieve improvement of press mould process.

  • PDF