• Title/Summary/Keyword: Profile measurements

Search Result 543, Processing Time 0.022 seconds

Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

  • Kim, Hyungsuk;Yoo, Chang Hyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.2
    • /
    • pp.71-79
    • /
    • 2020
  • Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman's method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and -1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and -0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

MODIS-estimated Microphysical Properties of Clouds Developed in the Presence of Biomass Burning Aerosols (MODIS 관측자료를 이용한 러시아 산불 영향 하에 발달한 구름의 미세 물리적 특성 연구)

  • Kim, Shin-Young;Sohn, Byung-Ju
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.289-298
    • /
    • 2008
  • An algorithm was developed to retrieve both cloud optical thickness and effective particle radius considered the aerosol effect on clouds. This study apply the algorithm of Nakajima and Nakajima (1995) that is used to retrieve cloud optical thickness and effective particle radius from visible, near infrared satellite spectral measurements. To retrieve cloud properties, Look-up table (LUT) was made under different atmospheric conditions by using a radiative transfer model. Especially the vertical distribution of aerosol is based on a tropospheric aerosol profile in radiative transfer model. In the case study, we selected the extensive forest fire occurred in Russia in May 2003. The aerosol released from this fire may be transported to Korea. Cloud properties obtained from these distinct atmospheric situations are analysed in terms of their possible changes due to the interactions of the clouds with the aerosol particle plumes. Cloud properties over the East sea at this time was retrieved using new algorithm. The algorithm is applied to measurements from the MODerate Resolution Imaging Spectrometer (MODIS) onboard the Terra spacecrafts. As a result, cloud effective particle radius was decreased and cloud optical thickness was increased during aerosol event. Specially, cloud effective particle radius is hardly greater than $20{\mu}m$ when aerosol particles were present over the East Sea. Clouds developing in the aerosol event tend to have more numerous but smaller droplets.

An Analysis of the Rail Wear Measurements for the Prediction of Particulate Matter Emission in Urban Railway (도시철도 미세먼지 발생량 예측을 위한 레일 마모량 분석)

  • Yoon, Cheonjoo;Ko, Huigyu;Bang, Myeongseok;Kwon, Hyeokbin
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.339-350
    • /
    • 2018
  • The rail wear measurements in urban underground railway have been analyzed to predict the particulate matter emission caused by rail wear which is one of the major sources of particulate matter emission for underground railway systems. From the rail profile variations measured in the interval of one and half year by dedicated rail wear measuring instrument over the commercial urban underground railway line, 'line-s' which is about 45km long, the characteristics as well as the amount of rail wear have been analyzed after dividing the whole line into about 170 section with radius of curve(R). It has been concluded that the vertical wear parameter V0 and corner wear parameter C0 have been selected to represent the wear amount of straight and curved rail respectively. The amount of rail wear as well as the particulate matter emission by rail wear over the whole line normalized by the rail length as well as the number of train has also been deduced from the relationship between the rail wear parameters and the amount of rail cross-section area.

Tip and taper compatibility of accessory gutta-percha points with rotary and reciprocating instruments

  • Julia Niero Zanatta Streck; Sabrina Arcaro;Renan Antonio Ceretta;Eduardo Antunes Bortoluzzi;Lucas da Fonseca Roberti Garcia;Josiane de Almeida ;Patricia Maria Poli Kopper ;Anarela Vassen Bernardi
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.22.1-22.8
    • /
    • 2023
  • Objectives: This study was conducted to evaluate and compare the tip and taper compatibility of accessory gutta-percha points (AGPs) with various rotary and reciprocating instruments. Materials and Methods: Using a profile analyzer, tip and taper measurements were taken of 10 AGPs of each of the 14 models available from Odous de Deus and the 4 models available from Dentsply-Maillefer. Diameter measurements were taken at 1-mm intervals, from 3 mm from the tip (D3) to 16 mm. Results: Based on the mean values obtained, 3-dimensional (3D) models of the AGPs were drawn in Autodesk Fusion 360 and superimposed on 3D models of each instrument selected (Mtwo, Reciproc, RaCe, K3, and ProDesign Logic) to determine the compatibility between the instrument and the AGP. Data corresponding to the tips and tapers of the various AGPs, as well as the tip and taper differences between the AGPs and the instruments, were analyzed using descriptive statistics. The tapers of the AGPs were subject to the American National Standards Institute/American Dental Association No. 57 standard. The Odous de Deus extra-long medium and extra-long extra-medium AGPs were shown to be compatible with Mtwo, K3, and ProDesign Logic instruments with taper 0.06 and tip sizes 25 and 30, while the Dentsply fine and fine medium cones were compatible with Mtwo, RaCe, and K3 instruments with conicity of 0.04 and tip sizes 35 and 40. Conclusions: Both the Odous de Deus and Dentsply commercial brands included 2 AGP models with tip (D3) and taper compatibility with Mtwo, RaCe, K3, and/or Prodesign Logic instruments.

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

A Study of Dosimetric Characteristics of a Diamond Detector for Small Field Photon Beams (광자선 소조사면에 대한 다이아몬드 검출기의 선량특성에 관한 연구)

  • Loh, John-K.;Park, Sung-Y.;Shin, Dong-O.;Kwon, Soo-I.;Lee, Kil-D.;Kim, Woo-C.;Cho, Young-K.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.195-203
    • /
    • 1999
  • It is difficult to determine dosimetric characteristics for small field photon beams since such small fields do not achieve complete lateral electronic equilibrium and have steep dose gradients. Dosimetric characteristics of small field 4, 6, and 10 MeV photon beams have been measured in water with a diamond detector and compared to measurements using small volume cylindrical and plane parallel ionization chambers. Percent depth dose (PDD) and beam profiles for 6 and 10 MeV photon beams were measured with diamond detector and cylindrical ion chamber for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. Total scatter factors($S_{c,p}$) for 4, 6, and 10 MeV photon beams were measured with diamond detector, cylindrical and plane parallel ion chambers for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. The $S_{c,p}$ factors obtained with three detectors for 4, 6, and 10 MeV photon beams agreed well ($\pm1.2%$) for field sizes greater than $2{\times}2,\;2.5{\times}2.5,\;and\;3{\times}3\;cm^2$, respectively. For smaller field sizes, the cylindrical and plane parallel ionization chambers measure a smaller $S_{c,p}$ factor, as a result of the steep dose gradients across their sensitive volumes. The PDD values obtained with diamond detector and cylindrical ionization chamber for 6 and 10MeV photon beams agreed well ($\pm1.5%$) for field sizes greater than $4{\times}4\;cm^2$. For smaller field sizes, diamond detector produced a depth-dose curve which had a significantly shallower falloff than that obtained from the measurements of relative depth-dose with a cylindrical ionization chamber. For the measurements of beam profiles, a distortion in terms of broadened penumbra was observed with a cylindrical ionization chamber since diamond detector exhibited higher spatial resolution. The diamond detector with small sensitive volume, near water equivalent, and high spatial resolution is suitable detector compared to ionization chambers for the measurements of small field photon beams.

  • PDF

SEMI-LONGITUDINAL STUDY ON GROWTH AND DEVELOPMENT OF CHILDREN AGED 6 TO 17 -Part III : GROWTH CHANGE OF CRANIOFACIAL HARD TISSUE (한국인 6-17세 아동의 성장과 발육에 관한 준종단적 연구 -제 3 세부 과제 : 두개 및 안면 경조직의 성장변화)

  • Hwang, Chung-Ju;Kil, Jea-Kyoung;Lim, Seon-A
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.469-485
    • /
    • 1996
  • Orthodontic patients are individuals that grow and develop ; therefore selection of the proper time for orthodontic treatment is considered to be one of most difficult and yet difficult factor. Since the development of cephalometric X-ray, amount and Pattern of craniofacial growth change with aging could be predicted and be came useful in the process of orthodontic treatment. The relationship between the mean values of cephalometric measurements and body height and weight was studied among the groups(boys and girls) of Korean children from the ages 6-years to 17-years. 409 boys and 437 girls with no abnormality in growth and development and no history of orthodontic treatment from the ages of 6 years to 17 years were chosen as subjects Cephaloment X-ray were taken for 3 years and hard tissue analysis based on Burstone's COGS, which was devided into measurements of 6 parts(Cranial base, Maxillar and Mandible, Dental measurements). The relationship between craniofacial growth and height & weight was studied. The following conclusions were obtained : 1. The maximum growth in the measurements of cranial base, N-Ar(FH), N-Ba(FH) corresponded with the age with the maximum increase in body height & weight in both boys and girls. 2. Genial angle gradually decreased with aging in both boys and girls. 3. N-ANS(L) showed greater amount of growth than ANS-Ne(L), and this had greater influence on facial profile. 4. N-A-$Pog^{\circ}$ decreased with aging, and mandibular growth exceeded maxillary growth in amount and rate. 5. Length of Y-axis Increased, but Y-axis to FH plane remained constant. This show that mandible grows at a constant angulation to cranial base. 6. As permanent teeth erupt, interincisal angle deceased.

  • PDF

Changes in SPAD Chlorophyll Value of Chrysanthemum (Dendranthema grandiflora Tzvelev) by Photoperiod and Light Intensity (광주기와 광도에 따른 국화 잎의 SPAD 엽록소 함량의 변화)

  • Lee, Byung-Joo;Won, Mi-Kyoung;Lee, Dong-Hee;Shin, Dong-Gi
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.555-559
    • /
    • 2001
  • This research was conducted to estimate the chlorophyll contents of chrysanthemum leaves using SPAD-502 chlorophyll meter under different photoperiod and light intensity. Measurements were done at every third leaf intervals starting from the top of the stem to the bottom at harvest time. SPAD value was highest at 10 hours of photoperiods, followed by 13 and 16 hours of photoperiods. In particular, under short day condition, SPAD value was highest in the young leaves below the flower bud and decreased down the leaf profile. Under long day condition, SPAD value reached maximum at leaves between $15-27^{th}$ from the top and decreased to the minimum immediately below the flower bud (youngest leaf). These results may indicate that the younger leaves become strong source of supporting flowers in reproductive stage, while the younger leaves serve as sinks and older leaves support their development in vegetative stage. Changes of SPAD value at different levels of irradiance showed that highest SPAD value were observed at high irradiance and decreased with decreasing irradiance.

  • PDF

Aeroelastic-aerodynamic analysis and bio-inspired flow sensor design for boundary layer velocity profiles of wind turbine blades with active external flaps

  • Sun, Xiao;Tao, Junliang;Li, Jiale;Dai, Qingli;Yu, Xiong
    • Smart Structures and Systems
    • /
    • v.20 no.3
    • /
    • pp.311-328
    • /
    • 2017
  • The characteristics of boundary layers have significant effects on the aerodynamic forces and vibration of the wind turbine blade. The incorporation of active trailing edge flaps (ATEF) into wind turbine blades has been proven as an effective control approach for alleviation of load and vibration. This paper is aimed at investigating the effects of external trailing edge flaps on the flow pattern and velocity distribution within a boundary layer of a NREL 5MW reference wind turbine, as well as designing a new type of velocity sensors for future validation measurements. An aeroelastic-aerodynamic simulation with FAST-AeroDyn code was conducted on the entire wind turbine structure and the modifications were made on turbine blade sections with ATEF. The results of aeroelastic-aerodynamic simulations were combined with the results of two-dimensional computational fluid dynamic simulations. From these, the velocity profile of the boundary layer as well as the thickness variation with time under the influence of a simplified load case was calculated for four different blade-flap combinations (without flap, with $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$ flap). In conjunction with the computational modeling of the characteristics of boundary layers, a bio-inspired hair flow sensor was designed for sensing the boundary flow field surrounding the turbine blades, which ultimately aims to provide real time data to design the control scheme of the flap structure. The sensor element design and performance were analyzed using both theoretical model and finite element method. A prototype sensor element with desired bio-mimicry responses was fabricated and validated, which will be further refined for integration with the turbine blade structures.

Comparison of Wave Stresses in the Eulerian Nearshore Current Models (오일러형 해빈류 모형의 파랑응력 비교)

  • Ahn, Kyungmo;Suh, Kyung-Duck;Chun, Hwusub
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.350-362
    • /
    • 2017
  • The Eulerian nearshore current model is more advantageous than the Lagrangian model in the way that numerical results from the Eulerian model can be directly compared with the measurements by the stationary equipment. It is because the wave mass flux is not included in the computed mass flux of Euleran nearshore current model. In addition, the Eulerian model can simulate the longshore currents with depth varying parabolic profile. However, the numerical models proposed by different researcher have different forms of the wave stress terms. For example, wave stresses in Newberger and Allen's (2007) model is constant over the depth, while those of Chun (2012) are vertically distributed. In the present study, these wave stress terms were compared against Hamilton et al.'s (2001) laboratory experiments to see the effects of different wave stress terms performed on the computation of nearshore currents.